AEHH8P, NEMA PREMIUM [NP]
AEHH8PCF, NEMA PREMIUM, FOOTED C-FACE [NP_C]
AEUH8PDC, NEMA PREMIUM, ROUND BODY C-FACE [NPV_C]
APPLICATIONS:
z Fans & Blowers z Compressors
z Pumps z Mixers
z Crushers z Conveyors
FEATURES:
z Output Range: 1 - 200 HP
z Speed: 3600, 1800 & 1200 RPM
z Enclosure: Totally Enclosed Fan Cooled (IP54 )
z Voltage: 230/460V (Usable on 208V); 150HP and Larger is 460V Only
z Three Phase, 60 Hz, 1.15 Service Factor (Continuous); 50 Hz, 1.0 Service Factor (Continuous)
z CSA Certified for Class I, Div. 2, Groups B, C, D - Temp Code T3C Minimum
z Class F Insulation
z Class B Temperature Rise
z NEMA Design B Torques as a Minimum; Various Ratings also Meet Design C
z Cast Iron Frame and End Brackets; Rolled Steel Fan Cover and Main Conduit Box
z Grounding Terminal Inside Main Conduit Box
z Oversized Main Conduit Box Rotatable in 90 Degree Increments - F1 Mounted
z Designed for 40˚C Ambient Temperature
z Designed for 3300 ft. Elevation
(3)
z Bi-Directional Rotation
z 1045 Carbon Steel Shaft
z Aluminum Die Cast Squirrel Cage Rotor Construction
z Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat
z Paint Color: Dark Gray - Munsell 7.5B 3.5/0.5
z Double Shielded Bearings Pre-Packed with MULTEMP SRL for F# 140T - 280T (Non-regreasable)
z High Quality Ball (or Roller) Bearings Regreasable with Mobil Polyrex™ EM for F# 280TS and Larger
z Automatic Grease Discharge Fittings on Regreasable Models
z Labyrinth Type Metal Flinger on Both Ends for F# 280TS and Larger
z Cast Iron Inner and Outer Bearing Caps for F#280TS and Larger
z Stainless Steel Nameplate
z New Dual Column Design Nameplate as Standard (60/50 Hz)
z Suitable for Inverter Use per NEMA MG-1 Part 31.4.4.2
z Inverter Duty Speed Range: 20:1 Variable Torque, 10:1 Constant Torque
z 9 Leads for 5 HP and Smaller;
z 12 Leads for 7.5 HP to 125 HP;
z 6 Leads for 150 HP and Larger
z Motors are U.L. Recognized, CSA Approved and CE Marked
z Dual Drilled Feet Available on Most Ratings - Longer Frames (i.e. 145T Drilled also for 143T)
z Provisions for Breather Drains for Vertical Mount Down (F# 324T and Larger)
z Rubber Dust Flinger on Drive-End for F# 140T - 280T
(2)
Effective 07-08-18
Supercedes 03-24-17
(1)
(4,5)
EXTRAS/ OPTIONS:
Please refer to pages 147 - 154 for common modifications that can be performed.
Notes:
(1) Motors 7.5 HP & up are Suitable for Wye/Delta Starting.
(2) Consult a Stock Product Application Specialist for suitability in higher ambient environments.
(3) Consult a Stock Product Application Specialist for suitability at higher elevations.
(4) Motor service factor is 1.0 when operated on a VFD.
(5) Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG-1. Part 31
MAX-pE™
AEHH8P, NEMA PREMIUM [NP]
Effective 07-08-18
Supercedes 03-24-17
CATALOG NO. HP RPM FRAME FL EFF (%) FL PF (%)
FL AMPS
(460V)
NP0012 1 3600 143T 82.5 85.0 1.34 83
(C)
NP0014
1 1800 143T 85.5 73.0 1.50 48
NP0016 1 1200 145T 82.5 65.5 1.73 90
NP1/52 1.5 3600 143T 84.0 83.5 2.00 85
(C)
NP1/54
1.5 1800 145T 86.5 78.0 2.08 78
NP1/56 1.5 1200 182T 87.5 63.5 2.53 120
NP0022 2 3600 145T 86.5 86.0 2.52 62
(C)
NP0024
NP0026
(C)
2 1800 145T 86.5 78.0 2.78 90
2 1200 184T 88.5 70.5 3.00 132
NP0032 3 3600 182T 88.5 90.0 3.53 130
(C)
NP0034
NP0036
(C)
3 1800 182T 89.5 84.0 3.74 135
3 1200 213T 89.5 78.0 4.02 164
NP0052 5 3600 184T 88.5 92.5 5.72 135
(C)
NP0054
NP0056
(C)
5 1800 184T 89.5 85.5 6.12 133
5 1200 215T 91.0 82.5 6.24 210
NP7/52 7.5 3600 213T 91.0 89.0 8.67 180
(C)
NP7/54
NP7/56
(C)
7.5 1800 213T 91.7 86.5 8.85 200
7.5 1200 254T 91.0 80.5 9.59 315
NP0102 10 3600 215T 91.0 89.5 11.5 220
(C)
NP0104
NP0106
(C)
10 1800 215T 91.7 88.0 11.6 219
10 1200 256T 91.0 80.5 12.8 340
NP0152 15 3600 254T 92.4 91.5 16.6 325
(C)
NP0154
NP0156
(C)
15 1800 254T 92.4 88.0 17.3 316
15 1200 284T 92.4 83.5 18.2 530
NP0202 20 3600 256T 92.4 92.5 21.9 380
(C)
NP0204
NP0206
(C)
20 1800 256T 93.0 87.5 23.0 395
20 1200 286T 91.7 84.0 24.3 520
NP0252 25 3600 284TS 92.4 91.0 27.8 460
(C)
NP0254
NP0254S
NP0256
(C)
(C)
25 1800 284T 93.6 86.0 29.1 510
25 1800 284TS 93.6 86.0 29.1 510
25 1200 324T 93.0 83.0 30.3 745
NP0302 30 3600 286TS 93.0 91.0 33.2 508
(C)
NP0304
NP0304S
NP0306
(C)
(C)
30 1800 286T 93.6 87.5 34.3 545
30 1800 286TS 93.6 87.5 34.3 545
30 1200 326T 93.0 80.5 37.5 775
NP0402 40 3600 324TS 94.1 90.0 44.2 650
(C)
NP0404
NP0404S
NP0406
(C)
(C)
40 1800 324T 94.1 86.0 46.3 710
40 1800 324TS 94.1 86.0 46.3 710
40 1200 364T 94.1 86.5 46.0 945
NP0502 50 3600 326TS 94.1 91.0 54.7 775
(C)
NP0504
NP0504S
NP0506
(C)
(C)
50 1800 326T 94.5 87.0 56.9 795
50 1800 326TS 94.5 87.0 56.9 795
50 1200 365T 94.1 86.0 57.8 1040
Notes:
(1) All data subject to change without notice.
(2) Ratings 150 HP and larger are 460V only.
(C) Meets NEMA Design C Torque.
APPROX
SHIPPING WT.
(lbs.)