Teco MAX-IE3 METRIC Catalog Page

MAX-IE3™ METRIC
AESV3W, IEC, IE3 EFFICIENCY [MP]
APPLICATIONS:
z Fans & Blowers z Any Application that Requires IEC Mounting Dimensions z Pumps z Compressors
z Output Range: 1 - 150 HP (0.75 - 112 kW) z Speed: 3600, 1800 & 1200 RPM z Enclosure: Totally Enclosed Fan Cooled (IP55) z Voltage: 230/460V (Usable on 208V) z Three Phase, 60 Hz, 1.15 Service Factor (Continuous); 50 Hz, 1.0 Service Factor (Continuous) z Class F Insulation z Class B Temperature Rise z Cast Iron Frame, End Brackets and Main Conduit Box; Rolled Steel Fan Cover z Grounding Terminal Inside Main Conduit Box z Oversized Main Conduit Box Rotatable in 90 Degree Increments - F3 Mounted (IM1001) z Designed for 40˚C Ambient Temperature z Designed for 3300 ft. Elevation z Bi-Directional Rotation z 1045 Carbon Steel Shaft z Aluminum Die Cast Squirrel Cage Rotor Construction z Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat z Paint Color: Blue - Munsell 5PB 3/8 z Double Shielded Bearings Pre-Packed with MULTEMP SRL for F# 80 - 225 (Non-regreasable) z High Quality Ball (or Roller) Bearings Regreasable with with MULTEMP SRL for F# 250 and Larger z Oil Seal/V-Ring on Both Ends z Stainless Steel Nameplate z New Dual Column Design Nameplate as Standard (60/50 Hz) z Suitable for Inverter Use per NEMA MG-1 Part 31.4.4.2 z Inverter Duty Speed Range: 20:1 Variable Torque, 10:1 Constant Torque z 12 Leads to 280 Frame and 6 Leads to 315 Frame and Up. z Motors are CE Marked
(1)
Ratings 150 HP and up are 460V only
(2)
(3)
(4,5)
Effective 07-08-18
Supercedes 03-24-17
EXTRAS/ OPTIONS:
Please refer to pages 147 - 154 for common modifications that can be performed.
Notes:
(1) Suitable for Wye/Delta Starting and part winding on 230V. (2) Consult a Stock Product Application Specialist for suitability in higher ambient environments. (3) Consult a Stock Product Application Specialist for suitability at higher elevations. (4) Motor service factor is 1.0 when operated on a VFD. (5) Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated by NEMA MG-1. Part 31.
MAX-IE3™ METRIC
AESV3W, IEC, IE3 EFFICIENCY [MP]
Effective 07-08-18
Supercedes 03-24-17
CATALOG
NO.
MP0012 0.75 1 3600 80M 77.0 84.0 1.46 18 (40) MP0014 0.75 1 1800 80M 85.5 74.5 1.48 21 (46) MP0016 0.75 1 1200 90S 82.5 70.0 1.63 28 (61) MP1/52 1.1 1.5 3600 80M 84.0 85.0 1.93 20 (44) MP1/54 1.1 1.5 1800 90S 86.5 81.0 1.97 27 (59) MP1/56 1.1 1.5 1200 112M 87.5 64.0 2.47 31 (68) MP0022 1.5 2 3600 90S 85.5 89.5 2.46 25.5 (56) MP0024 1.5 2 1800 90L 86.5 75.0 2.90 28.5 (63) MP0026 1.5 2 1200 112M 88.5 69.0 3.08 43.5 (96) MP0032 2.2 3 3600 90L 86.5 89.0 3.59 29 (64) MP0034 2.2 3 1800 100L 89.5 83.5 3.69 39.5 (87) MP0036 2.2 3 1200 112M 89.5 67.5 4.09 53.5 (118) MP0042 3.0 4 3600 100L 88.5 88.0 4.83 41.5 (91.5) MP0044 3.0 4 1800 100L 89.5 78.5 5.36 42 (93) MP0046 3.0 4 1200 132S 89.5 78.5 5.36 75 (165) MP5/52 4.0 5.5 3600 112M 88.5 91.0 6.23 51 (113.5) MP5/54 4.0 5.5 1800 112M 89.5 81.5 6.88 53 (117) MP5/56 4.0 5.5 1200 132M 89.5 79.5 7.06 91.5 (202) MP7/52 5.5 7.5 3600 132S 89.5 86.5 8.92 73 (161) MP7/54 5.5 7.5 1800 132S 91.7 85.0 8.86 75.5 (166) MP7/56 5.5 7.5 1200 132M 91.0 74.5 10.2 91 (200) MP0102 7.5 10 3600 132S 90.2 87.5 11.9 76 (167) MP0104 7.5 10 1800 132M 91.7 85.5 12.0 93 (205) MP0106 7.5 10 1200 160M 91.0 81.5 12.7 135 (298) MP0152 11 15 3600 160M 91.0 92.5 16.4 130 (287) MP0154 11 15 1800 160M 92.4 87.0 17.2 131 (287) MP0156 11 15 1200 160L 91.7 81.5 18.5 150 (331) MP0202 15 20 3600 160M 91.0 92.5 22.4 130 (287) MP0204 15 20 1800 160L 93.0 86.5 23.4 150 (331) MP0206 15 20 1200 180L 91.7 83.0 24.7 205 (452) MP0252 18.5 25 3600 160L 91.7 93.0 27.2 140 (308.5) MP0254 18.5 25 1800 180M 93.6 82.5 30.1 195 (430) MP0256 18.5 25 1200 200L 93.0 82.0 30.4 270 (595) MP0302 22 30 3600 180M 91.7 90.0 32.0 180 (397) MP0304 22 30 1800 180L 93.6 84.0 33.6 205 (452) MP0306 22 30 1200 200L 93.0 82.0 34.6 290 (639) MP0402 30 40 3600 200L 92.4 91.0 42.8 265 (584) MP0404 30 40 1800 200L 94.1 89.5 42.8 285 (628) MP0406 30 MP0502 37 50 3600 200L 93.0 91.0 52.5 300 (661) MP0504 37 50 1800 225S 94.5 86.5 54.3 350 (772) MP0506 37 50 1200 250M 94.1 88.0 53.6 460 (1014) MP0602 45 60 3600 225M 93.6 93.5 61.7 340 (750) MP0604 45 60 1800 225M 95.0 86.5 65.7 360 (794) MP0606 45 60 1200 280S 94.5 85.5 69.5 600 (1322) MP0752 56 75 3600 250M 93.6 93.0 75.9 465 (1025) MP0754 56 75 1800 250M 95.4 88.0 78.7 480 (1058) MP0756 56 75 1200 280M 94.5 84.5 87.9 660 (1455) MP1002 75 100 3600 280S 94.1 89.5 111 585 (1290) MP1004 75 100 1800 280S 95.4 87.5 112 620 (1367) MP1006 75 100 1200 315S 95.0 84.0 117 900 (1984) MP1252 93 125 3600 280M 95.0 89.5 138 615 (1356) MP1254 93 125 1800 280M 95.4 88.5 139 690 (1521) MP1256 93 125 1200 315M 95.0 84.5 146 960 (2116) MP1502 112 150 3600 315S 95.0 91.0 162 860 (1896) MP1504 112 150 1800 315S 95.8 88.0 167 960 (2116) MP1506 112 150 1200 315M 95.8 84.5 173 1160 (2557)
N
otes:
(1) All data subject to change without notice.
KW HP RPM FRAME FL EFF (%) FL PF (%)
40 1200 225M 94.1 86.5 44.2 385 (849)
FL AMPS
(460V)
APPROX.
SHIPPING
WT. KG (lbs.)
Loading...