Teco MAX-HT™ LOW VOLTAGE CRUSHER DUTY Catalog Page

MAX-hT™ LOW VOLTAGE CRUShER DUTy
AEHHGD, NEMA PREMIUM, DESIGN A [CDP]
APPLICATIONS:
z Crushers z Ball Mills/ Rolling Mills z Impactors z Any High Torque Application z Chippers/ Shredders
z Output Range: 200 - 500 HP z Speed: 1800, 1200 & 900 RPM z Enclosure: Totally Enclosed Fan Cooled (IP55) z Voltage: 460V z Three Phase, 60 Hz, 1.15 Service Factor (Continuous); 50 Hz, 1.0 Service Factor (Continuous) z CSA Certified for Class I, Div. 2, Groups B, C, D - Temp Code T3 Minimum z CSA Certified for Class II, Div. 2, Groups F & G - Temp Code T3 Minimum (Frame 444T and above) z Class F Insulation z Class B Temperature Rise z NEMA Design A Torques; Equal or Greater Than 200% Starting Torque / 250% Breakdown Torque z Cast Iron Frame, End Brackets; Pressed Steel Plate Main Conduit Box and Fan Cover z Cast Iron Main Conduit Box on 505UZ Frame z Grounding Terminal Inside Main Conduit Box with additional Foot Grounding Provision z Oversized Main Conduit Box Rotatable in 90 Degree Increments - F1 Mounted z Designed for 40˚C Ambient Temperature z Designed for 3300 ft. Elevation z Bi-Directional Rotation z High Strength 4140 AISI Steel Shaft z Aluminum Die Cast Squirrel Cage Rotor Construction z Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat z Paint Color: Dark Gray - Munsell 7.5 BG 3.5/0.5 z High Quality Ball (or Roller) Bearings Regreasable with Mobil Polyrex™ EM z Automatic Grease Discharge Fittings z Labyrinth Type Metal Flinger on Both Ends z Cast Iron Inner and Outer Bearing Caps z Stainless Steel Nameplate z New Dual Column Design Nameplate as Standard (60/50 Hz) z Suitable for Inverter Use per NEMA MG-1 Part 31.4.4.2 z Inverter Duty Speed Range: 20:1 Variable Torque, 10:1 Constant Torque (350 HP and Larger are 3:1 Constant Torque) z 6 Leads z Standard With Thermistors (PTC 140˚C) 1 per Phase z Locknut and Washer on NDE for Vertical Shaft Down Applications z Drain Holes / Plugs on Both End Brackets for Vertical Applications z Threaded One Way Breather Drains for Horizontal Mount Applications
(1)
(6)
(6)
(2)
(3)
(4,5)
Effective 07-08-18
Supercedes 03-24-17
EXTRAS/ OPTIONS:
Please refer to pages 147 - 154 for common modifications that can be performed.
Notes:
(1) 575V motors available on a made-to order basis. Consult a Stock Product Application Specialist for details. (2) Consult a Stock Product Application Specialist for suitability in higher ambient environments. (3) Consult a Stock Product Application Specialist for suitability at higher elevations. (4) Motor service factor is 1.0 when operated on a VFD. (5) Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG-1. Part 31. (6) CSA Certification for Hazardous Locations only applies to AEHHGD, NEMA Premium Type.
MAX-hT™ LOW VOLTAGE CRUShER DUTy
AEHHGD, NEMA PREMIUM, DESIGN A [CDP]
Effective 07-08-18
Supercedes 03-24-17
CATALOG NO. HP RPM FRAME FL EFF (%) FL PF (%)
CDP2006RZ 200 1200 505UZ 95.8 79.9 245 3,200
CDP2008R 200 900 5007C 94.5 80.2 247 2,000
CDP2008RZ 200 900 586/7UZ 94.5 77.2 257 2,370
CDP2504TB 250 1800 449T 96.2 85.0 286 2,750
CDP2504TR 250 1800 449TZ 96.2 85.0 286 2,760
CDP2504R 250 1800 5007C 96.2 82.4 295 3,620
CDP2504RZ 250 1800 505UZ 96.2 82.4 295 3,250
CDP2506TR 250 1200 449TZ 95.8 78.5 311 2,925
CDP2506R 250 1200 5007C 95.8 80.4 304 3,760
CDP2506RZ 250 1200 586/7UZ 95.8 80.2 305 4,850
CDP2508R 250 900 5009C 95.0 81.9 301 2,250
CDP2508RZ 250 900 586/7UZ 95.0 78.1 316 2,450
CDP3004TR 300 1800 449TZ 96.2 84.0 348 2,865
CDP3004R 300 1800 5007C 96.2 83.5 350 3,750
CDP3004RZ 300 1800 586/7UZ 96.2 82.7 353 4,900
CDP3006TR
CDP3006R 300 1200 5009C 95.8 83.0 353 4,350
CDP3006RZ 300 1200 586/7UZ 95.8 81.7 359 4,950
CDP3504TR 350 1800 449TZ 96.2 88.5 385 3,290
CDP3504R 350 1800 5009C 96.2 86.2 395 4,140
CDP3504RZ 350 1800 586/7UZ 96.2 82.7 412 5,050
CDP3506R 350 1200 5806C 95.8 79.5 430 5,680
CDP3506RZ 350 1200 586/7UZ 95.8 80.6 424 5,100
CDP4004R 400 1800 5806C 96.2 83.3 467 5,650
CDP4004RZ 400 1800 586/7UZ 96.2 83.2 468 5,200
CDP4504R 450 1800 5808C 96.2 82.5 531 5,650
CDP4504RZ 450 1800 586/7UZ 96.2 82.8 529 5,300
CDP5004R 500 1800 5808C 96.2 85.6 569 5,860
CDP5004RZ 500 1800 586/7UZ 96.2 84.4 577 5,450
Notes:
(1) All data subject to change without notice. (2) CDP3006TR is not suitable for 50HZ operation and the nameplate data will not include 50HZ data.
(2)
300 1200 449TZ 95.8 82.5 355 3,450
FL AMPS
(460V)
APPROX.
SHIPPING.
WT. (lbs.)