ISSUED
TYPE
OUTPUT
HP KW
8/29/2014
AEUH8BDC
POLE
FRAME
6
326TC
VARIABLE TORQUE
SIZE
PERFORMANCE DATA
3-PHASE INDUCTION MOTOR
NAMEPLATE INFORMATION
VOLTAGE
460
HZ
6030 22.4
RATED
AMBIENT
50oC
VARIABLE FREQUENCY DRIVE SERVICE
INS.
CLASS
F
NEMA
DESIGN
OHMS/PHASE EQUIVALENT WYE CIRCUIT
(AT RATED OPERATING TEMPERATURE 25
ENCLOSURE
TEFC
CATALOG#
HBV0306C
TIME
RATING
B
CONT.
SERVICE
FACTOR
1.15
o
C)
HZ
3~60
HZ
6~60
FULL
LOAD
RPM
1175
HP X1
CONSTANT TORQUE
HP
3~30
RPM
60~12000.0038~30
RPM
120~1200
(lb-ft)
0.332~134.1
(lb-ft)
R1 R2
0.1129 0.2135
CONSTANT HORSEPOWER
HZ HP RPM
60~90134.1
30 1200~1800 134.1~89.4
TYPICAL PERFORMANCE
FULL LOAD
MIN.% NOM.%
3/4 LOAD%1/2 LOAD
%
FULL LOAD%3/4 LOAD%1/2 LOAD
91.7 93 93.6 93.6 80.5 78.5 71
NO LOAD FULL LOAD
AT
460
VOLT
AT
460
VOLT
LOCKED ROTOR
AT
460
VOLT
11.6 37.50 218
0.6729
%
NEMA
KVA
CODE
LETTER
G
X2
1.1569
(lb-ft)
SOUND
PRESSURE
LEVEL @ 3 FT
Db(A)
X
22.143
72
SAFE STALL
TIME IN
SECONDS
COLD HOT
17 12
m
FULL
LOAD
(lb-ft)
134.10 210 180 230 12.372 384
APPROVED:
TORQUE
LOCKED
ROTOR
%FLT
PULL
UP
%FLT
BREAK
DOWN
%FLT
M. PRATER
INERTIA
ROTOR
WR
(lb-ft2)
DRAWING NO.
LOAD
2
WK
(lb-ft2)
NEMA
ALLOWABLE
2
WK
(lb-ft2)
2
LOAD
636
31057HBV0306C
ACCEL TIME (DOL)
MAX
ALLOWABLE
WK
Sec
2
WK
Sec
9.155.59
2
ALLOWABLE
STARTS
PER HOUR
COLD
2
REVISION:
HOT
1
1