Teco HB5008 Data Sheet
...
Teco Data Sheet
Specifications and Main Features
Frequently Asked Questions

ISSUED
08/28/14
TYPE
AEHH8B
PERFORMANCE DATA
3-PHASE INDUCTION MOTOR
NAMEPLATE INFORMATION
OUTPUT
HP KW
500 373 60
POLE
8
FRAME
SIZE
5810B
VOLTAGE
460
TYPICAL PERFORMANCE
FULL
LOAD
RPM
FULL LOAD
MIN. % NOM. %
EFFICIENCY
3/4 LOAD
1/2 LOAD
%
94.1 95.2 95 94
HZ
RATED
AMBIENT
50oC
%
INS.
CLASS
F
POWER FACTOR
F. L.
%
3/4 LOAD%1/2 LOAD
82.5
NEMA
DESIGN
B
%
80 71
ENCLOSURE
TEFC
CATALOG#
HB5008
TIME
RATING
CONT.
MAXIMUM
POWER FACTOR
CORRECTION
SERVICE
FACTOR
1.15
KVAR85890
CURRENTS
NO LOAD FULL LOAD
107 596
TORQUE
FULL LOAD
lb-ft
LOCKED
ROTOR
%FLT
PULL
UP
%FLT
2949 90 72
SAFE STALL
TIME IN
SECONDS
COLD HOT
ALLOWABLE
STARTS
PER HOUR
COLD
28 18
APPROVED: REVISION
M. PRATER
LOCKED ROTOR
3625
BREAK
DOWN
%FLT
ROTOR
WR
lb-ft
625
SOUND
PRESSURE
LEVEL @ 3 FT
HOT
DRAWING NO.
2
2
dB(A)
852 1
NEMA KVA
CODE LETTER
G
INERTIA
NEMA
LOAD
WK
lb-ft
ALLOWABLE
2
2
10400
3A057HB5008
MAX
2
WK
2
lb-ft
20800
ACCEL TIME
NEMA
LOAD
WK
Sec
ALLOWABLE
2
7.37200 14.31
MAX
WK
Sec
2
0
Loading...