Teco HB2504 Data Sheet

TORQUE
TORQUE
CURRENTS
NEMA
POWER FACTOR
EFFICIENCY
TORQUE
ISSUED
MAX
TYPE
OUTPUT
HP
8/28/2014
AEHH8B
POLE
KW
4
PERFORMANCE DATA
3-PHASE INDUCTION MOTOR
FRAME
SIZE
449T250
VARIABLE TORQUE
VOLTAGE
460
VARIABLE FREQUENCY DRIVE SERVICE
NAMEPLATE INFORMATION
HZ
60187
RATED
AMBIENT
50oC
INS.
CLASS
F
OHMS/PHASE EQUIVALENT WYE CIRCUIT
(AT RATED OPERATING TEMPERATURE 25
NEMA
DESIGN
B
ENCLOSURE
CATALOG#
TIME
RATING
CONT.
TEFC
HB2504
SERVICE
FACTOR
1.15
C)
HZ
3~60
HZ
6~60
FULL
LOAD
RPM
1787
HP
CONSTANT TORQUE
HP
25~250 60~90734
RPM
90~18000.0313~250
RPM
180~1800 250 1800-2700 734~489.33
(lb-ft)
1.826~734
(lb-ft)
HZ HP RPM
R1 R2 X1
0.0179 0.018
CONSTANT HORSEPOWER
TYPICAL PERFORMANCE
FULL LOAD
MIN.% NOM.%
3/4 LOAD%1/2 LOAD
%
FULL LOAD%3/4 LOAD%1/2 LOAD
95.4 96.2 95.8 95 88 84.5 80
NO LOAD FULL LOAD
AT
460
VOLT
53.8
AT
460
VOLT
277.00
LOCKED ROTOR
AT
460
VOLT
1825
0.76 0.3753
%
NEMA
KVA
CODE
LETTER
G
X2
X
9.6
(lb-ft)
SOUND
PRESSURE
LEVEL @ 3 FT
Db(A)
81
SAFE STALL
TIME IN
SECONDS
COLD HOT
19 13
m
FULL
LOAD
(lb-ft)
734.00 110 90 210 83 1017
APPROVED:
TORQUE
LOCKED
ROTOR
%FLT
PULL
UP
%FLT
BREAK
DOWN
%FLT
M. PRATER
INERTIA
ROTOR
WR
(lb-ft2)
DRAWING NO.
LOAD
2
WK
(lb-ft2)
ALLOWABLE
2
ACCEL TIME (DOL)
NEMA
LOAD
WK
Sec
2
WK
(lb-ft2)
2
2034
31057HB2504
MAX
ALLOWABLE
WK
Sec
2
10.575.49
ALLOWABLE
STARTS
PER HOUR
COLD
2
REVISION:
HOT
1
1