ISSUED
March 13, 2012
TYPE
AEHH8B
PERFORMANCE DATA
3-PHASE INDUCTION MOTOR
NAMEPLATE INFORMATION
OUTPUT
HP KW
125 93.3 60
POLE
8
FRAME
SIZE
447T
VOLTAGE
230/460
TYPICAL PERFORMANCE
FULL
LOAD
RPM
FULL LOAD
MIN. % NOM. %
92.4 91.7
EFFICIENCY
3/4 LOAD
%
93.6 93
1/2 LOAD
HZ
RATED
AMBIENT
40oC
%
INS.
CLASS
F
POWER FACTOR
F. L.
%
3/4 LOAD%1/2 LOAD
80
NEMA
DESIGN
B
%
77 69
ENCLOSURE
TEFC
CATALOG#
HB1258
TIME
RATING
CONT.
MAXIMUM
POWER FACTOR
CORRECTION
SERVICE
FACTOR
1.15
KVAR48888
NO LOAD FULL LOAD LOCKED ROTOR
AT
208
VOLT
132.69 120.00
FULL LOAD
lb-ft
AT
230
VOLT
TORQUE
LOCKED
ROTOR
%FLT
AT
460
VOLT
60.00 156.00312.00 1815.00
PULL
UP
%FLT
739 150 125 200
SAFE STALL
TIME IN
SECONDS
COLD HOT
26 18
ALLOWABLE
STARTS
PER HOUR
COLD HOT
2 1
AT
208
VOLT
BREAK
DOWN
%FLT
CURRENTS
AT
230
VOLT
ROTOR
2
WR
2
lb-ft
141
SOUND
PRESSURE
LEVEL @ 3 FT
dB(A)
74
AT
460
VOLT
NEMA
LOAD
WK
lb-ft
2919
2
2
AT
208
VOLT
MAX
ALLOWABLE
WK
lb-ft
2
2
7297
AT
230
VOLT
NEMA
LOAD
WK
Sec
7.16
AT
460
VOLT
907.50345.00
ACCEL TIMEINERTIA
ALLOWABLE
2
NEMA
KVA
CODE
LETTER
MAX
2
WK
Sec
17.41
G2006.97
APPROVED: REVISION
M. PRATER
DRAWING NO.
3A057HB1258R
0