Teco GP7/54G Data Sheet

ISSUED
12/27/13
TYPE
AEGHSGR
PERFORMANCE DATA
3-PHASE INDUCTION MOTOR
NAMEPLATE INFORMATION
OUTPUT
HP KW
7.5 5.60 60
POLE
FRAME
SIZE
213T
VOLTAGE
230/460
TYPICAL PERFORMANCE
FULL
LOAD
RPM
FULL LOAD
MIN. % NOM. %
90.2 90.5
EFFICIENCY
3/4 LOAD
%
91.7 91.0
RATED
HZ
AMBIENT
40oC
1/2 LOAD
%
INS.
CLASS
F
POWER FACTOR
F. L.
%
3/4 LOAD%1/2 LOAD
83.0
ENCLOSURE
CATALOG#
NEMA
DESIGN
B
%
79.0 68.0
TEFC
GP7/54G
TIME
RATING
CONT.
MAXIMUM
POWER FACTOR
CORRECTION
SERVICE
FACTOR
1.15
KVAR2.431760
NO LOAD FULL LOAD LOCKED ROTOR
AT
208
VOLT
5.89 7.20
FULL LOAD
lb-ft
AT
230
VOLT
TORQUE
LOCKED
ROTOR
%FLT
AT
460
VOLT
3.60 9.3018.50 127.00
PULL
UP
%FLT
22.37 265 215 330
SAFE STALL
TIME IN
SECONDS
COLD HOT
29 20
ALLOWABLE
STARTS
PER HOUR
COLD HOT
2 1
AT
208
VOLT
BREAK
DOWN
%FLT
CURRENTS
AT
230
VOLT
ROTOR
2
WR
2
lb-ft
0.84
SOUND
PRESSURE
LEVEL @ 3 FT
dB(A)
64
AT
460
VOLT
NEMA
LOAD
WK lb-ft
39
2 2
AT
208
VOLT
MAX
ALLOWABLE
WK
lb-ft
2 2
117
AT
230
VOLT
NEMA
LOAD
WK
Sec
3.77
AT
460
VOLT
63.5020.57
ACCEL TIMEINERTIA
ALLOWABLE
2
NEMA
KVA
CODE
LETTER
MAX
2
WK
Sec
11.15
H114.85
APPROVED: REVISION
M. PRATER
DRAWING NO.
31057GP7/54G
0