Teco GH0/72 Reference Drawing

2
3600
.56
ALLOWABLE
STARTS
PER HOUR
COLD
HOT
2
1
APPROVED:
REVISION
COLD
HOT
35
24
M. PRATER
DRAWING NO.
31057G0/72
SOUND
PRESSURE
LEVEL @ 3 FT
dB(A)
16.22
NEMA
LOAD
WK
2
Sec
MAX
ALLOWABLE
WK
2
Sec
SAFE STALL
TIME IN
SECONDS
1.2
310
300
345
NEMA
LOAD
WK
2
lb-ft
2
PULL
UP
%FLT
1.02
1.24
AT
460
VOLT
AT
208
VOLT
AT
208
VOLT
AT
230
VOLT
AT
230
VOLT
AT
460
VOLT
7.50
2.43
0.62
1.10
2.20
15.00
BREAK
DOWN
%FLT
NEMA
KVA
CODE
LETTER
J
13.57
ACCEL TIME
INERTIA
0.033
ROTOR
WR
2
lb-ft
2
TORQUE
FULL LOAD
lb-ft
LOCKED
ROTOR
%FLT
5.1
3420
FULL
LOAD
RPM
POWER FACTOR
3/4 LOAD
%
1/2 LOAD
%
F. L.
%
847674
FULL LOAD
MIN. %
NOM. %
3/4 LOAD
%
0.9
MAX
ALLOWABLE
WK
2
lb-ft
2
CURRENTS
NO LOAD
FULL LOAD
LOCKED ROTOR
3.09
AT
208
VOLT
AT
230
VOLT
AT
460
VOLT
TIME
RATING
CONT.
SERVICE
FACTOR
1.15
75
63
MAXIMUM
POWER FACTOR
CORRECTION
KVAR
0.5
INS.
CLASS
F
NEMA
DESIGN
B
VOLTAGE
230/460
HZ
RATED
AMBIENT
40oC
ISSUED
December 9, 2016
TYPE
AEGH
ENCLOSURE
TEFC
CATALOG#
GH0/72
PERFORMANCE DATA
3-PHASE INDUCTION MOTOR
63.7
OUTPUT
POLE
2
FRAME
SIZE
56
EFFICIENCY
1/2 LOAD
%
72
70
DATE: CATALOG NO.:
GH0/72
June 27, 2005
CONNECTION DIAGRAM
SCHEMATIC - 2Y/Y CONNECTION
G0/24
ACROSS THE LINE CONNECTION
LINE
230 VOLT CONNECTION
LINE
460 VOLT CONNECTION
DWG NO.
DAC-1566-2
INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS
Frames 56 and 143T - 449TZ
Loading...