Teco EP0028 Reference Drawing

NOVEMBER 2, 2016
ISSUED
October 31, 2016
TYPE
AEHH8N
PERFORMANCE DATA
3-PHASE INDUCTION MOTOR
NAMEPLATE INFORMATION
OUTPUT
HP KW
2 1.5 60
POLE
8
FRAME
SIZE
VOLTAGE
213T 460
TYPICAL PERFORMANCE
FULL
LOAD
RPM
FULL LOAD
MIN. % NOM. %
82.5 82.5
EFFICIENCY
3/4 LOAD
%
85.5 84
RATED
HZ
AMBIENT
40oC
1/2 LOAD
%
INS.
CLASS
F
POWER FACTOR
F. L.
%
3/4 LOAD%1/2 LOAD
64
ENCLOSURE
CATALOG#
NEMA
DESIGN
C
%
55 42.5
TEFC
EP0028
TIME
RATING
CONT.
MAXIMUM
POWER FACTOR
CORRECTION
SERVICE
FACTOR
1.15
KVAR4865
NO LOAD FULL LOAD LOCKED ROTOR
AT
230
VOLT
AT
460
VOLT
4.80 2.4
TORQUE
FULL LOAD
lb-ft
LOCKED
ROTOR
%FLT
PULL
UP
%FLT
12.14 225 200 275
SAFE STALL
TIME IN
SECONDS
COLD HOT
80 56
ALLOWABLE
STARTS
PER HOUR
COLD HOT
2 1
CURRENTS
AT
230
VOLT
AT
460
VOLT
6.80 3.4 50.00
BREAK
DOWN
%FLT
ROTOR
2
WR
2
lb-ft
NEMA
LOAD
WK lb-ft
ALLOWABLE
2 2
59
SOUND
PRESSURE
LEVEL @ 3 FT
dB(A)
52
AT
230
VOLT
MAX
WK lb-ft
285
NEMA
AT
460
VOLT
25
ACCEL TIMEINERTIA
NEMA
2 2
LOAD
WK
Sec
ALLOWABLE
2
6.020.586
KVA
CODE
LETTER
MAX
2
WK
Sec
28.83
L
APPROVED:
M. PRATER
DRAWING NO.
31057EP0028
REVISION
DATE: CATALOG NO.:
December 2, 2005
ACROSS THE LINE CONNECTION
CONNECTION DIAGRAM
SCHEMATIC - Δ / Y CONNECTION
EP0028
LINE
230 VOLT CONNECTION
460 VOLT CONNECTION
LINE
WYE START-DELTA RUN CONNECTION
LINE LINE LINE LINE
230 VOLT START 230 VOLT RUN 460 VOLT START 460 VOLT RUN
DWG NO.
DAC-1565-4
INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS
Frames 56 and 143T - 449TZ