ISSUED
TYPE
OUTPUT
HP KW
1 0.7
8/15/2014
AEHH8N
POLE
4
PERFORMANCE DATA
3-PHASE INDUCTION MOTOR
FRAME
SIZE
143T
VARIABLE TORQUE
VOLTAGE
230/460HZ60
VARIABLE FREQUENCY DRIVE SERVICE
NAMEPLATE INFORMATION
RATED
AMBIENT
40oC
INS.
CLASS
F
OHMS/PHASE EQUIVALENT WYE CIRCUIT
(AT RATED OPERATING TEMPERATURE 25
NEMA
DESIGN
B
ENCLOSURE
CATALOG#
TIME
RATING
CONT.
TEFC
EP0014
SERVICE
FACTOR
1.15
o
C)
HZ
3~60
HZ
6~60
HP
CONSTANT TORQUE
HP
.1~1 60~1203.009
RPM
90~18000.0001~1
RPM
180~1800 1 1800~3600 3.009~1.505
TYPICAL PERFORMANCE
FULL
LOAD
RPM
1745
AT
208
VOLT
FULL LOAD
MIN.% NOM.%
82.5 85.5 84 81.5 73 64.5 51.5
NO LOAD FULL LOAD
AT
230
VOLT
AT
460
VOLT
3/4 LOAD%1/2 LOAD
AT
208
VOLT
AT
230
VOLT
1.67 1.60 0.8 3.32 3.00
(lb-ft)
0.006~3.009
(lb-ft)
%
AT
460
VOLT
HZ HP RPM
FULL LOAD%3/4 LOAD%1/2 LOAD
AT
208
VOLT
8.1425 6.5479 18.783 11.565
LOCKED ROTOR
1.50 27.1 30.0 15
R1 R2 X1
CONSTANT HORSEPOWER
%
NEMA
KVA
AT
230
VOLT
AT
460
VOLT
CODE
LETTER
N
X2
X
313.61
(lb-ft)
SOUND
PRESSURE
LEVEL @ 3 FT
Db(A)
49
SAFE STALL
TIME IN
SECONDS
COLD HOT
71 50
m
FULL
LOAD
(lb-ft)
3.01 310 280 410
APPROVED:
TORQUE
LOCKED
ROTOR
%FLT
PULL
UP
%FLT
BREAK
DOWN
%FLT
M. PRATER
INERTIA
ROTOR
WR
(lb-ft2)
LOAD
2
WK
(lb-ft2)
0.086 5.8
DRAWING NO.
ALLOWABLE
2
ACCEL TIME (DOL)
NEMA
LOAD
WK
Sec
2
WK
(lb-ft2)
2
46
31057EP0014
MAX
ALLOWABLE
WK
Sec
2
26.703.41
ALLOWABLE
STARTS
PER HOUR
COLD
2
REVISION:
HOT
1
1