ISSUED
10/7/2015
TYPE
ASGHPE
PERFORMANCE DATA
3-PHASE INDUCTION MOTOR
NAMEPLATE INFORMATION
OUTPUT
HP KW
3
FRAME
SIZE
2
562.24
VOLTS
230/460
TYPICAL PERFORMANCE
FULL
LOAD
RPM
FULL LOAD
MIN% NOM%
3/4 LOAD%1/2 LOAD
3480 82.5 85.5 86.0 84.5
%
HZPOLE
AMBIENT
60
FULL LOAD
RATED
40oC
%
INS.
CLASS
NEMA
DESIGN
RATING
F B CONT.
3/4 LOAD
%
1/2 LOAD
%
ENCLOSURE
ODP
CATALOG#
DSP0032
TIME
POWER FACTOR
SERVICE
FACTOR
MAXIMUM
CORRECTION
KVAR86.0 81.0 71.0 1.29
1.15
VOLT
ROTOR
2
WR
2
lb-ft
FULL LOAD
AT
208
LOAD
WK
AT
230
VOLT
2
2
AT
460
VOLT
ALLOWABLE
WK
2
2
200
VOLT
73.6 70.8
NO LOAD
AT
200
VOLT
2.87 K
1.3 1.2
FULL
LOAD
lb-ft
AT
208
VOLT
AT
230
VOLT
AT
460
VOLT
AT
200
VOLT
3.11 3.8 1.9 8.79 8.45 7.6
LOCKED
ROTOR
%FLT
PULL
UP
%FLT
BREAK
DOWN
%FLT
4.53 365 335 350
SAFE STALL
TIME IN
SECONDS
COLD
HOT COLD HOT
17 12
APPROVED:
ALLOWABLE
STARTS
PER HOUR
2 1
M. PRATER
SOUND
PRESSURE
LEVEL @ 3 FT
dB(A)
61
DRAWING NO.
31057DSP0032
LOCKED ROTOR
AT
LOAD
2
WK
2.85
AT
208
VOLT
AT
230
VOLT
64.0 32.03.8
ALLOWABLE
WK
2
8.320.082 3.5 10.4
AT
460
VOLT
LETTER
REV.
NEMA
KVA
CODE
0