Teco DJPP1/52 Reference Drawing

60
0
NO LOAD
AT
200
VOLT
AT
208
VOLT
AT
230
VOLT
AT
460
VOLT
LOCKED ROTOR
CURRENTS
AT
230
VOLT
AT
460
VOLT
AT
200
VOLT
AT
208
VOLT
AT
200
VOLT
AT
208
VOLT
AT
230
VOLT
AT
460
VOLT
ENCLOSURE
CATALOG#
ODP
DJPP1/52
ISSUED
TYPE
10/28/2016
ASGHJP
PERFORMANCE DATA
3-PHASE INDUCTION MOTOR
SAFE STALL
TIME IN
SECONDS
ALLOWABLE
STARTS
PER HOUR
SOUND
PRESSURE
LEVEL @ 3 FT
dB(A)
COLD
HOT
COLD
HOT
REV.
60
18132
1
APPROVED:
M. PRATER
DRAWING NO.
31057DJPP1/52
6.32
INERTIA
0.059
1.8
4.6
NEMA
LOAD
WK
2
lb-ft
2
MAX
ALLOWABLE
WK
2
lb-ft
2
ACCEL TIME
2.52
NEMA
LOAD
WK
2
Sec.
MAX
ALLOWABLE
WK
2
Sec.
2.24
400
310
450
M
NEMA
KVA
CODE
LETTER
FULL
LOAD
lb-ft
LOCKED
ROTOR
%FLT
PULL
UP
%FLT
BREAK
DOWN
%FLT
TORQUE
ROTOR
WR
2
lb-ft
2
34.8
36.2
40.0
20.0
4.55
4.38
3.96
1.98
1.44
1.55
1.90
0.95
KVAR
83.0
76.5
64.0
0.61
3/4 LOAD
%
1/2 LOAD
%
NEMA
DESIGN
VOLTS
POWER FACTOR
MAXIMUM
POWER FACTOR
CORRECTION
85.5
83.0
EFFICIENCY
%
3/4 LOAD
%
1/2 LOAD
%
RATED
AMBIENT
INS.
CLASS
2
FRAME
SIZE
143T
NAMEPLATE INFORMATION
TYPICAL PERFORMANCE
FULL
LOAD
RPM
MIN%
NOM%
SERVICE
FACTOR
1.15
3510
81.5
85.5
1.5
1.12
TIME
RATING
40oC
FBCONT.
OUTPUT
HP
KW
230/460
HZ
POLE
DATE: CATALOG NO.:
June 17, 2005
DJPP1/52
CONNECTION DIAGRAM
SCHEMATIC - 2Y/Y CONNECTION
ACROSS THE LINE CONNECTION
LINE
LINE
230 VOLT CONNECTION
460 VOLT CONNECTION
2DWG NO.
DAC-1566-2
INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS
Frames 56 and 143T - 449TZ
5100 North IH 35 Round Rock, Texas 78681