Teco DJMP0106 Reference Drawing

NEMA
lb-ft
MAX
lb-ft
NEMA
MAX
ISSUED
10/28/2016
TYPE
ASGHJM
PERFORMANCE DATA
3-PHASE INDUCTION MOTOR
ENCLOSURE
ODP
CATALOG#
DJMP0106
NAMEPLATE INFORMATION
OUTPUT
HP KW
POLE
FRAME
SIZE
6
VOLTS
230/460
HZ
60
RATED
AMBIENT
40oC
INS.
CLASS
F B CONT.
NEMA
DESIGN
TIME
RATING
SERVICE
FACTOR
TYPICAL PERFORMANCE
FULL
LOAD
RPM MIN% NOM%
FULL LOAD
EFFICIENCY
3/4 LOAD%1/2 LOAD
FULL LOAD
%
90.0 89.5
CURRENTS
NO LOAD FULL LOAD
AT
200
VOLT
AT
208
VOLT
AT
230
VOLT
AT
460
VOLT
AT
200
VOLT
AT
208
VOLT
AT
230
VOLT
9.2 10.0 12.2 6.1 H
POWER FACTOR MAXIMUM
%
3/4 LOAD%1/2 LOAD
%
POWER FACTOR
73.5 61.0 4.13
LOCKED ROTOR
AT
460
VOLT
AT
200
VOLT
AT
208
VOLT
AT
230
VOLT
140.9 146.5
CORRECTION
KVAR79.51165 90.2 91.7
AT
460
VOLT
81.029.6 28.4 25.7 12.9 162.0
1.15
NEMA
KVA
CODE
LETTER
TORQUE
FULL
LOAD
lb-ft
LOCKED
ROTOR
%FLT
PULL
UP
%FLT
BREAK
DOWN
%FLT
45.07 230 180 240
SAFE STALL
TIME IN
SECONDS
COLD HOT
APPROVED:
ALLOWABLE
STARTS
PER HOUR
COLD HOT
M. PRATER
ROTOR
2
WR
2
lb-ft
2.859
SOUND
PRESSURE
LEVEL @ 3 FT
dB(A)
6125 18 2 1
DRAWING NO.
INERTIA
LOAD
WK
ALLOWABLE
2 2
WK
137 411
ACCEL TIME
2 2
LOAD
WK Sec.
5.50
ALLOWABLE
2
2
WK
Sec.
16.28
31057DJMP0106
REV.
0
DATE: CATALOG NO.:
June 28, 2005
CONNECTION DIAGRAM
SCHEMATIC - 2Δ / Δ CONNECTION
DJMP0106
ACROSS THE LINE CONNECTION
LINE
230 VOLT CONNECTION
LINE
460 VOLT CONNECTION
DWG NO.
DAC-1564-1
INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS
Frames 56 and 143T - 449TZ