ISSUED
10/28/2016
TYPE
ASGHJM
PERFORMANCE DATA
3-PHASE INDUCTION MOTOR
ENCLOSURE
CATALOG#
DJMP0014
NAMEPLATE INFORMATION
OUTPUT
HP KW
1 0.75
FRAME
SIZE
4
143T
VOLTS
230/460
HZPOLE
60
RATED
AMBIENT
40oC
INS.
CLASS
F B CONT.
NEMA
DESIGN
TIME
RATING
TYPICAL PERFORMANCE
FULL
LOAD
RPM MIN% NOM%
FULL LOAD
EFFICIENCY
3/4 LOAD%1/2 LOAD
%
FULL LOAD
%
POWER FACTOR
3/4 LOAD%1/2 LOAD
%
POWER FACTOR
CORRECTION
1750 82.5 85.5 85.0 82.0
CURRENTS
NO LOAD
AT
200
VOLT
1.36 1.47 1.80 0.90 30.0 15.0
AT
208
VOLT
AT
230
VOLT
AT
460
VOLT
AT
200
VOLT
3.34 3.21 2.90 1.45 N
FULL LOAD LOCKED ROTOR
AT
208
VOLT
AT
230
VOLT
AT
460
VOLT
AT
200
VOLT
AT
208
VOLT
AT
230
VOLT
26.1 27.1
VOLT
ODP
SERVICE
FACTOR
1.15
MAXIMUM
KVAR75.5 67.0 54.0 0.61
AT
460
LETTER
NEMA
KVA
CODE
FULL
LOAD
lb-ft
TORQUE
LOCKED
ROTOR
%FLT
PULL
UP
%FLT
BREAK
DOWN
%FLT
ROTOR
2
WR
2
lb-ft
INERTIA
LOAD
WK
ALLOWABLE
2
2
WK
3.00 365 310 410 9.650.1 5.8 17.4
SAFE STALL
TIME IN
SECONDS
COLD
HOT COLD HOT
44 31 2 1
APPROVED:
ALLOWABLE
STARTS
PER HOUR
M. PRATER
SOUND
PRESSURE
LEVEL @ 3 FT
dB(A)
52
DRAWING NO.
31057DJMP0014
ACCEL TIME
2
2
LOAD
WK
Sec.
ALLOWABLE
2
WK
Sec.
2
3.25
REV.
0

DATE: CATALOG NO.:
June 17, 2005
CONNECTION DIAGRAM
SCHEMATIC - 2Y/Y CONNECTION
DJMP0014
ACROSS THE LINE CONNECTION
LINE
230 VOLT CONNECTION
LINE
460 VOLT CONNECTION
DWG NO.
DAC-1566-2

INSTALLATION AND
MAINTENANCE INSTRUCTIONS
FOR THREE PHASE
INDUCTION MOTORS
Frames 56 and 143T - 449TZ