ISSUED
April 10, 2019
TYPE
ASHH
PERFORMANCE DATA
3-PHASE INDUCTION MOTOR
NAMEPLATE INFORMATION
OUTPUT
HP KW
5 3.7 60
POLE
4
FRAME
SIZE
184T
VOLTAGE
230/460
TYPICAL PERFORMANCE
FULL
LOAD
RPM
FULL LOAD
MIN. % NOM. %
87.5 90.2
EFFICIENCY
3/4 LOAD
89.5
%
90.2 84.5
RATED
HZ
AMBIENT
40oC
1/2 LOAD
%
INS.
CLASS
POWER FACTOR
F. L.
%
3/4 LOAD%1/2 LOAD
81.0
NEMA
DESIGN
B
ENCLOSURE
CATALOG#
TIME
RATING
CONT.
%
71.5
ODP
DHP0054G
SERVICE
FACTOR
1.15F
MAXIMUM
POWER FACTOR
CORRECTION
KVAR2.01740
CURRENTS
NO LOAD FULL LOAD LOCKED ROTOR
AT
208
VOLT
5.6 2.6 6.212.4
FULL LOAD
lb-ft
AT
230
VOLT
5.1
LOCKED
ROTOR
%FLT
AT
460
VOLT
PULL
UP
%FLT
AT
208
VOLT
BREAK
DOWN
%FLT
15.09 195 190 300
SAFE STALL
TIME IN
SECONDS
COLD HOT
30 21
ALLOWABLE
STARTS
PER HOUR
COLD HOT
2 1
AT
230
VOLT
ROTOR
2
WR
2
lb-ft
SOUND
PRESSURE
LEVEL @ 3 FT
dB(A)
NEMA
53
AT
460
VOLT
LOAD
WK
lb-ft
27
2
2
AT
208
VOLT
MAX
ALLOWABLE
WK
lb-ft
2
2
AT
230
VOLT
92.0
NEMA
LOAD
WK
Sec
AT
460
VOLT
46.013.7
ACCEL TIMEINERTIATORQUE
ALLOWABLE
2
NEMA
KVA
CODE
LETTER
MAX
2
WK
Sec
11.384.430.40 70
J101.7
APPROVED: REVISION
K. Lo
DRAWING NO.
31057DHP0054G
0