ISSUED
TYPE
OUTPU
HP
100 / 25
11/15/06
AECA
FULL
LOAD
RPM
1770 / 880
ENCLOSURE
PERFORMANCE DATA
3-PHASE INDUCTION MOTOR
2 SPEED 1 WINDING, VARIABLE TORQUE
NAMEPLATE INFORMATION
POLE
4/8
FRAME
SIZE
444T
VOLTAGE
460
HZ
60
RATED
AMBIENT
40oC
INS.
CLASS
F
NEMA
DESIGN
B
TYPICAL PERFORMANCE
EFFICIENC
FULL LOAD
MIN. % NOM. %
91.6 / 87.1 89.0 / 82.0
NO LOAD FULL LOAD LOCKED ROTO
AT
460
VOLT
92.5 / 88.0 91.8 / 86.5 90.0 / 62.0
26.4 / 22.1
3/4 LOAD
%
1/2 LOAD
%
CURRENT
AT
460
VOLT
112 / 42.9
POWER FACTO
F. L.
%
3/4 LOAD%1/2 LOAD
87.0 / 55.0 74.0 / 42.0
CATALOG#
TIME
RATING
CONT.
%
AT
460
VOLT
790 / 240
TEFC
CP1004/8
SERVICE
FACTOR
1.15
KVA
CODE
LETTER
G / H
TORQUE
FULL LOAD
lb-ft
LOCKED
ROTOR
%FLT
PULL
UP
%FLT
297 / 149 120 / 130 108 / 117
SAFE STALL
TIME IN
SECONDS
COLD HOT
28 / 40 20 / 30
APPROVED: REVISION
M. PRATER
BREAK
DOWN
%FLT
220 / 230
ALLOWABLE
PER HOUR
COLD HOT
21
DRAWING NO.
ROTOR
STARTS
2
WR
2
lb-ft
42.6
31057CP1004/8
INERTI
NEMA
LOAD
2
WK
2
lb-ft
441 / 647
SOUND
PRESSURE
LEVEL @ 3 FT
dB(A)
85
MAX
ALLOWABLE
WK
lb-ft
2
2
662 / 1294
0