Teco CDP1504R Data Sheet

TORQUE
MAX
NEMA
ISSUED
POWER FACTOR
EFFICIENCY
TORQUE
TORQUE
6/13/2019
TYPE
AEHHGD
OUTPUT
HP KW
150 111.9
PERFORMANCE DATA
POLE
VARIABLE TORQUE
FRAME
SIZE
445T
4
VARIABLE FREQUENCY DRIVE SERVICE
3-PHASE INDUCTION MOTOR
NAMEPLATE INFORMATION
VOLTAGE
460
HZ
60
RATED
AMBIENT
40oC
INS.
CLASS
F
OHMS/PHASE EQUIVALENT WYE CIRCUIT (AT RATED OPERATING TEMPERATURE 25
NEMA
DESIGN
ENCLOSURE
TEFC
CATALOG#
CDP1504R
TIME
RATING
C
CONT.
SERVICE
FACTOR
1.15
o
C)
HZ
3~60
HZ
6~60
FULL
LOAD
RPM
1783
HP
CONSTANT TORQUE
HP
15~150 60~90
RPM
90~18000.0188~150
180~1800
RPM
(lb-ft)
1.10~442
(lb-ft)
442
HZ HP RPM
R1
R2 X1
0.00809 0.0083 0.0746
CONSTANT HORSEPOWER
150 1800-2700 442~294.66
TYPICAL PERFORMANCE
FULL LOAD 1/2 LOAD
MIN.% NOM.%
3/4 LOAD%1/2 LOAD
%
FULL LOAD%3/4 LOAD
%
95 95.8 95.4 94.5 85 83 78
NO LOAD FULL LOAD LOCKED ROTOR
AT
460
VOLT
AT
460
VOLT
AT
460
VOLT
1085.0172.558.6
%
NEMA
KVA
CODE
LETTER
G
X2
0.127
SOUND
PRESSURE
LEVEL @ 3 FT
2.511
(lb-ft)
Db(A)
81
SAFE STALL
TIME IN
SECONDS
COLD HOT
20 15
X
m
FULL
LOAD
(lb-ft)
441.7 210.0 160.0 270.0 52.0 640.0
APPROVED:
TORQUE
LOCKED
ROTOR
%FLT
PULL
UP
%FLT
K. Lo
BREAK
DOWN
%FLT
INERTIA
ROTOR
WR
(lb-ft2)
DRAWING NO.
LOAD
2
WK
(lb-ft2)
NEMA
ALLOWABLE
2
WK
(lb-ft2)
2
LOAD
1280.0
31057CDP1504R
ACCEL TIME (DOL)
MAX
ALLOWABLE
2
WK
Sec
WK
Sec
7.94.1
2
ALLOWABLE
STARTS
PER HOUR
COLD
2
REVISION:
HOT
1
1
Loading...