CAST IRON ODp
ASHH, NEMA PREMIUM [DHP]*
APPLICATIONS:
z Fans & Blowers z HVAC Equipment z Pumps z Fire Pumps* z Compressors
z Output Range: 1 - 800 HP z Speed: 3600, 1800 & 1200 RPM z Enclosure: Open Drip Proof (IP22) z Voltage: 230/460V (Usable on 208V); 150HP and Larger is 460V Only z Three Phase, 60 Hz, 1.15 Service Factor (Continuous); 50 Hz, 1.0 Service Factor (Continuous) z Class F Insulation z Class B Temperature Rise z NEMA Design B Torques z Cast Iron Frame and End Brackets z Rolled Steel Main Conduit Box z Grounding Terminal Inside Main Conduit Box z Oversized Main Conduit Box Rotatable in 90 Degree Increments - F1 Mounted z Designed for 40˚C Ambient Temperature z Designed for 3300 ft. Elevation z Bi-Directional Rotation z 1045 Carbon Steel Shaft z Aluminum Die Cast Squirrel Cage Rotor Construction z Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat z Paint Color: Light Gray - Munsell N5.0 z Double Shielded Bearings Pre-Packed with MULTEMP SRL for F# 140T - 280T (Non-regreasable) z High Quality Ball (or Roller) Bearings regreasable with Mobil Polyrex™ EM for F# 280TS and Larger z Labyrinth Type Metal Flinger on Both Ends for F# 280TS and Larger z Cast Iron Inner and Outer Bearing Caps for F#280TS and Larger z Stainless Steel Nameplate z New Dual Column Design Nameplate as Standard (60/50 Hz) z Suitable for Inverter Use per NEMA MG-1 Part 31.4.4.2 z Inverter Duty Speed Range: 20:1 Variable Torque, 10:1 Constant Torque z 9 Leads for 5 HP and Smaller; z 12 Leads for 7.5 HP to 125 HP; z 6 Leads for 150 HP and Larger z Motors are U.L. Recognized, CSA Approved and CE Marked
Effective 07-08-18
Supercedes 03-24-17
(1)
(2)
(3)
(4,5)
EXTRAS/ OPTIONS:
Please refer to pages 147 - 154 for common modifications that can be performed.
Notes:
* Fire Pump available. See product page for more details.
(1) Available in 575V. TWMC carries minimal 575V stock; please check availability to ensure required motors are in stock.
Ratings may be available from our Canadian warehouses and/or our factory. Pricing and leadtime may vary. (2) Consult a Stock Product Application Specialist for suitability in higher ambient environments. (3) Consult a Stock Product Application Specialist for suitability in higher elevations. (4) Motor service factor is 1.0 when operated on a VFD. (5) Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG-1, Part 31.
CAST IRON ODp - FIRE pUMp
ASHH, NEMA PREMIUM [DHP_FP]*
Effective 07-08-18
Supercedes 03-24-17
FIRE PUMP
CATALOG NO.
DHP0014FP 1 1800 143T 85.5 78.0 1.41 54 DHP0016FP 1 1200 145T 82.5 65.5 1.74 75 DHP1/52FP 1.5 3600 143T 85.5 80.0 2.06 50 DHP1/54FP 1.5 1800 145T 86.5 80.5 2.02 60 DHP1/56FP 1.5 1200 182T 87.5 63.0 2.55 123 DHP0022FP 2 3600 145T 85.5 84.5 2.59 57 DHP0024FP 2 1800 145T 86.5 79.5 2.72 58 DHP0026FP 2 1200 184T 87.5 71.0 3.01 130 DHP0032FP 3 3600 145T 87.5 87.0 3.69 66 DHP0034FP 3 1800 182T 89.5 81.0 3.88 117 DHP0036FP 3 1200 213T 88.5 77.0 4.12 183 DHP0052FP 5 3600 182T 87.5 91.0 5.90 120 DHP0054FP 5 1800 184T 89.5 84.5 6.19 145 DHP0056FP 5 1200 215T 89.5 79.0 6.62 195 DHP7/52FP 7.5 3600 184T 88.5 91.5 8.65 134 DHP7/54FP 7.5 1800 213T 91.0 86.0 8.97 187 DHP7/56FP 7.5 1200 254T 90.2 79.0 9.85 260 DHP0102FP 10 3600 213T 90.2 88.0 11.8 190 DHP0104FP 10 1800 215T 91.7 87.0 11.7 215 DHP0106FP 10 1200 256T 91.7 81.0 12.6 329 DHP0152FP 15 3600 215T 90.2 87.5 17.8 220 DHP0154FP 15 1800 254T 93.0 84.5 17.9 247 DHP0156FP 15 1200 284T 91.7 83.0 18.5 367 DHP0202FP 20 3600 254T 91.0 90.5 22.8 233 DHP0204FP 20 1800 256T 93.0 86.5 23.3 350 DHP0206FP 20 1200 286T 92.4 83.5 24.3 392 DHP0252FP 25 3600 256T 91.7 92.0 27.7 317 DHP0254FP 25 1800 284T 93.6 87.0 28.7 352 DHP0256FP 25 1200 324T 93.0 83.0 30.3 640 DHP0302FP 30 3600 284TS 92.4 90.5 33.6 405 DHP0304FP 30 1800 286T 94.1 87.0 34.3 429 DHP0306FP 30 1200 326T 93.6 83.5 35.9 568 DHP0402FP 40 3600 286TS 92.4 91.5 44.3 442 DHP0404FP 40 1800 324T 94.1 86.0 46.3 608 DHP0406FP 40 1200 364T 94.1 87.0 45.7 835 DHP0502FP 50 3600 324TS 93.0 86.0 58.5 552 DHP0504FP 50 1800 326T 94.5 85.0 58.3 629 DHP0506FP 50 1200 365T 94.1 86.0 57.8 766 DHP0602FP 60 3600 326TS 93.6 87.0 69.0 614 DHP0604FP 60 1800 364T 95.0 85.0 69.6 735 DHP0606FP 60 1200 404T 94.5 85.5 69.5 1,100 DHP0752FP 75 3600 364TS 94.1 90.5 82.5 704 DHP0754FP 75 1800 365T 95.0 86.0 86.0 850
DHP0754RFP 75 1800 365T 95.0 86.0 86.0 850
DHP0756FP 75 1200 405T 94.5 86.5 86.0 1,210
DHP0756RFP 75 1200 405T 94.5 86.5 86.0 1,210
Notes:
* Fire Pump available as made to order. Fire Pump Certificate complies with ANSI/UL 1004-5. Certificate# 20120717 – EX6569. (1) Delivery for Fire Pump Duty motor (Catalog Number + FP) is standard 5 - 10 working days after receipt of order if standard motor is in stock. (2) Fire Pump Duty Motor pricing includes: adding UL nameplate, restamping original nameplate to new "DHP_FP" catalog number. (3) To order 575V, add "5" to the end of Catalog Number, for example: "DHP00545" for 5 HP, 1800 RPM, 575V. (4) "R" = Motor stocked standard with a Drive-End Roller Bearing. (5) Ratings 150 HP and larger are 460V only. (6) All data subject to change without notice.
HP RPM FRAME FL EFF (%) FL PF (%)
FL AMPS
(460V)
APPROX.
SHIPPING
WT. (lbs.)