Tecnoware EVO DSP PLUS MM 1.2, EVO DSP PLUS MM 2.4, EVO DSP PLUS MM 3.6 User Manual

Uninterruptible Power Supply
EVO DSP PLUS MM 1.2 EVO DSP PLUS MM 2.4 EVO DSP PLUS MM 3.6
Manuale utente
Index
User’s Manual - English ........................................................................ 1
Safety Warnings ................................................................................ 1
1 Introduction ................................................................................. 2
2 General Characteristics ................................................................... 3
3 Receipt and site selection ................................................................ 3
4 Operating Modes ........................................................................... 4
4.1 NORMAL Mode .......................................................................... 5
4.2 BATTERY Mode ......................................................................... 5
4.3 BYPASS Mode ........................................................................... 5
4.4 STAND-BY Mode ........................................................................ 6
4.5 ECO Mode ............................................................................... 6
4.6 CONVERTER FREQUENCY Mode ...................................................... 7
5 EXTERNAL DESCRIPTION .................................................................. 7
5.1 Front Panel ............................................................................. 7
5.1.2 Buttons .................................................................................... 10
5.1.3 Acoustic Alarm ........................................................................... 11
5.2 Rear Side .............................................................................. 11
6 Electrical Installation ..................................................................... 12
6.1 Installation ........................................................................... 13
7 First Start Up .............................................................................. 14
8 Functioning ................................................................................ 15
8.1 Turning ON and OFF ................................................................. 15
8.2 Low Battery and Automatic Restart ............................................... 15
8.3 Load Testing .......................................................................... 16
8.4 Static Bypass ......................................................................... 16
8.5 Battery Test .......................................................................... 17
8.6 Operation in Warning Status ....................................................... 17
8.7 Operation in Fault Mode ............................................................ 18
9 Communication Interfaces .............................................................. 18
10 Technical Characteristics ................................................................ 19
11 Maintenance ............................................................................... 21
11.1 UPS Cleaning ......................................................................... 21
11.2 Battery ................................................................................ 21
11.3 Operator Safety ...................................................................... 21
12 Troubleshooting ........................................................................... 22
Conformity to the European Directives ................................................... 24
Product Disposal ............................................................................... 24
Lead Batteries ................................................................................. 24
ENGLISH
UPS EVO DSP PLUS 1.2-2.4-3.6 MM 1 U
ser’s manual
User’s Manual - English
Safety Warnings
Read this manual carefully and completely before installing and using the EVO DSP PLUS MM
Uninterruptible Power Supply, which, from here after, will also be referred to as UPS.
The UPS must be used only by properly trained personnel. To ensure correct and safe
operations, it is necessary that operators and maintenance personnel observe the general safety Standards as well as the specific instructions included in this manual.
Risk of electric shock: do not remove the cover. The UPS contains internal parts which are at a
high Voltage and are potentially dangerous, capable of causing injury or death by electric shock.
There are no internal parts in the UPS which are user serviceable. Any repair or maintenance
work must be performed exclusively by qualified technical personnel authorized by producer. TECNOWARE declines any responsibility if this warning is disregarded.
The electric installation has to be done by qualified personnel. Follow all the Safety Standards
(CEI Standards in Italy or IEEE elsewhere) for the Input/Output connections and for the right section of Input/Output cables.
It is compulsory to ground the UPS according to Safety Standards. Risk of electric shock at the Output lines when the UPS is ON. Risk of electric shock at the Output lines while the unit is connected to the AC utility line. For respect of the Safety Standards is necessary the presence of a differential circuit breaker
between UPS Output lines and the loads.
We recommend to use a dedicate AC power line for the UPS. Do not obstruct ventilation slots or holes and do not rest any object on top of the UPS. Do not insert objects or pour liquids in the ventilation holes. Install the UPS indoors, in a protected, clean and moisture-free environment. Do not expose to the direct sun light. Do not keep liquids, flammable gases or corrosive substances near the UPS.
ENGLISH
User’s manual 2
UPS EVO DSP PLUS 1.2-2.4-3.6 MM
1 Introduction
The UPS EVO DSP PLUS MM (UPS means Uninterruptible Power Supply) is the result of constant technological research aimed at obtaining the best performance at the lowest cost.
EVO DSP PLUS MM is an advanced ON-LINE UPS built specifically to protect your computer from any irregularities in the AC line (for example blackouts, brownouts, over voltages, micro-interruptions), which often cause damage to hardware and software.
All that is possible because EVO DSP PLUS MM is a Double-Conversion ON-LINE UPS.
Under normal AC line condition EVO DSP PLUS MM provides an automatic Output Voltage regulation from the Rectifier and Inverter blocks and filters out frequently occurring electrical disturbances (high Voltage transients, spikes, interferences, etc.), this protecting the devices connected to its outlets. During a power failure, EVO DSP PLUS MM continues supplying adequate AC power (with a true sine wave) to all connected devices through its internal batteries and by its DC/AC converter (Inverter).
EVO DSP PLUS MM protects the devices from accidental overload or Inverter fault by an Automatic Bypass that directly connects the AC Input line with its outlets.
EVO DSP PLUS MM models are factory-equipped with USB interfaces, which may be used for notify to a computer a power failure or a Low Battery condition: this allows automatic data backup during an extended blackout with the most common operating systems (Windows, Linux, Unix, etc). Thanks to Interfaces, UPS EVO DSP PLUS MM can communicate the several made measurements (Input/Output Voltage, batteries, absorption, Frequency, etc.), and can also be programmed in order to start-up or shutdown automatically at fixed times.
Read this manual carefully before using the EVO DSP PLUS MM; it includes important safety warnings and useful advices for correct use and installation.
EVO DSP PLUS MM is constantly being developed and improved: consequently, your unit may differ somewhat from the description contained in this manual.
This manual includes the following models:
EVO DSP PLUS MM 1.2 (1.2 KVA)
EVO DSP PLUS MM 2.4 (2.4 KVA)
EVO DSP PLUS MM 3.6 (3.6 KVA)
In this manual EVO DSP PLUS MM will simply be referred to as UPS.
EVO DSP PLUS MM models are made from a single unit that contains the electronics parts and the batteries.
ENGLISH
UPS EVO DSP PLUS 1.2-2.4-3.6 MM 3 U
ser’s manual
2 General Characteristics
EVO DSP PLUS MM has all the advanced features which guarantee maximum reliability and safety:
Double-Conversion ON-LINE Transformerless technology
Sinusoidal wave generated by an IGBT Inverter
Output Voltage regulation ±2%
Protection from overload and short circuits
Automatic Bypass to protect from accidental overload or Inverter fault
Start-up even under Mains OFF conditions
Automatic protection when Battery is low
Automatic restart, following an automatic shut-down due to Low Battery, once AC utility power comes
back on
Selectable Input Frequency (50 or 60 Hz)
Graphic LCD panel for visualization of the Input and Output Voltage measurements, batteries Voltage,
percentage of load, frequency, alarms, overload, fault and path of energy flow
Acoustic signals of various kinds indicating alarm situations
Available settings of all the UPS parameters by user through front panel pushbuttons and graphic LCD
panel
SNMP Adapter (optional)
Communication with the computer through USB interfaces
ECO functioning mode (selectable)
Frequency Converter functioning mode (selectable)
High efficiency
Maximum reliability
Smart design and easy to use
3 Receipt and site selection
Carefully remove the UPS from its packaging, and carry out a meticulous inspection. We recommend keeping the original packaging in a secure place, in case you need to send the UPS for maintenance purposes. In case of transport damage, notify the carrier and dealer immediately.
We recommend paying attention to the below points in order to choose a correct placement for your UPS:
The UPS is designed to operate in a protected environment (e.g. offices). We therefore recommend
installing it in a place with very little or no humidity, dust or smoke.
When the UPS is brought from a cold place to a warmer place, humidity in the air may cause condensation
in the UPS. In this case, allow UPS to stand for two hours in the warmer place before beginning with the installation.
ENGLISH
User’s manual 4
UPS EVO DSP PLUS 1.2-2.4-3.6 MM
In all circumstances, see the “Technical Characteristics” chapter for environmental specifications and
check that the selected area meets these criteria.
During normal operation the UPS discharges a minimal amount of heat. So it is necessary to leave at least
10 cm of unobstructed space all around the UPS in order to keep it properly ventilated.
Do not obstruct ventilation holes.
Do not insert objects or pour liquids in the ventilation holes.
Do not rest any object on top of the UPS.
Do not keep liquids, flammable gases or corrosive substances near the unit.
Install the UPS on a properly tiled floor. Avoid the installation on a floor that is not tiled flat.
4 Operating Modes
Figure 1 – Operating modes
BATTERY MODE
NORMAL MODE
BYPASS MODE
ENGLISH
UPS EVO DSP PLUS 1.2-2.4-3.6 MM 5 U
ser’s manual
4.1 NORMAL Mode
The UPS typically works in Normal mode: Input mains power is available and its amplitude is within specifications. Please refer to figure 1.
After the filter has eliminated any high Frequency interference present on the mains, the AC Input line is rectified and conditioned in the Rectifier block (AC/DC conversion); the continuous power now enters into the Inverter block and is then reconverted into alternated power (DC/AC conversion), overcoming the Automatic Bypass and feeding the load after an extra filtration. At the same time the UPS recharges the batteries through the Battery Charger block.
Please refer to figure 2, which describe the UPS front panel.
The Normal mode is identified by:
The graphic LCD panel shows the path of energy flow
during Normal mode.
4.2 BATTERY Mode
During operation in Normal mode, if the UPS finds the Mains OFF condition (due to a Blackout or Overvoltage/Brownout), it then switches into Battery mode. In this case, the batteries supply the required Output power thanks to the DC/AC conversion carried out by the Inverter. The UPS switches back to Normal mode a few seconds after AC Input power is restored or Voltage comes back to internal specifications. Please refer to figure 1.
The Battery mode is identified by:
The graphic LCD panel shows the path of energy flow
during Battery mode.
An acoustic signal every 4 seconds.
4.3 BYPASS Mode
In Bypass mode, the AC Input line is directly connected with the UPS outlets by an Automatic Bypass.
As indicated in figure 1, in Bypass mode the UPS recharges the batteries.
During Normal mode, the UPS switches automatically to Bypass mode as a consequence of accidental overload or Inverter fault thus protecting the supplied devices.
When the UPS is working in Normal mode it is possible to switch the UPS by pressing continuously ON/MUTE and SELECT buttons at the same time for at least 5 seconds, as explained into chapter 5.
ENGLISH
User’s manual 6
UPS EVO DSP PLUS 1.2-2.4-3.6 MM
The Bypass mode is identified by:
The graphic LCD panel shows the path of energy flow
during Bypass mode.
An acoustic signal every 10 seconds.
During Bypass mode, loads are fed directly from AC Input line. Therefore no protection against AC Input line disturbances or interruptions is present.
4.4 STAND-BY Mode
If the UPS is in Stand-by mode, it is “inactive”. In Stand-by mode the Inverter is off and there is not Output power but the UPS is not completely off: indeed the UPS recharges the batteries regularly and the graphic display is ON.
If the OFF button is pressed when the UPS is in Normal mode, the UPS switches in Stand-by mode.
If the UPS is in Stand-by mode and the AC Input line is removed from UPS, then the UPS switches completely off.
The Stand-by mode is identified by:
The graphic LCD panel shows the path of energy flow
during Stand-by mode.
4.5 ECO Mode
It is possible to select the ECO mode to save energy and to increase the efficiency of the UPS.
The ECO mode uses the Bypass to feed the loads. The UPS will operate as in Bypass mode whenever the Frequency/waveform/RMS value of AC Input line mains Voltage is within their tolerance limits. If the AC Input line Voltage goes beyond these limits, the UPS switches into normal operation.
Please contact Technical Service for the instruction to enable the ECO mode; by default the ECO mode is disable.
ECO mode does not provide perfect stability in Frequency/waveform/RMS value of the Output Voltage like in Normal mode. Thus, the use of this mode should be carefully executed according to the level of protection required by the application.
The ECO mode is identified by:
The graphic LCD panel shows the path of energy flow
during ECO mode (the “ECO” icon is ON).