Tecnoware ECO STRIP 0.50, ECO STRIP 0.70, ECO STRIP 0.90, ECO STRIP 1.1, ECO STRIP 1.3 User Manual

Uninterruptible Power Supply
ECO STRIP 0.50 ECO STRIP 0.70 ECO STRIP 0.90
ECO STRIP 1.1 ECO STRIP 1.3
User’s manual
Index
Safety Warnings ................................................................................ 2
1 Introduction ................................................................................. 3
2 General Characteristics ................................................................... 3
3 Receipt and site selection ................................................................ 4
4 EXTERNAL DESCRIPTION .................................................................. 5
4.1 Front Panel ............................................................................. 5
4.2 Rear Side ................................................................................ 6
5 Electrical Installation and First Start Up ............................................... 7
6 Functioning ................................................................................. 8
6.1 Normal Mode ........................................................................... 8
6.2 Battery Mode ........................................................................... 8
6.3 Low Battery and Automatic Restart ................................................. 8
6.4 Load Control ............................................................................ 8
6.5 Fault Condition ........................................................................ 9
7 Communication Interface ................................................................. 9
8 Technical Characteristics ................................................................ 10
9 Maintenance ............................................................................... 11
9.1 UPS Cleaning ......................................................................... 11
9.2 Battery ................................................................................ 11
9.3 Battery Replacement ............................................................... 11
9.4 Operator Safety ...................................................................... 12
10 Troubleshooting ........................................................................... 13
Conformity to the European Directives ................................................... 14
Product Disposal ............................................................................... 14
Lead Batteries ................................................................................. 14
© Copyright 2012 TECNOWARE s.r.l. All rights reserved. All trademarks are property of their respective owners.
TECNOWARE s.r.l. Via Montetrini, 2E – Loc. Molino del Piano – 50065 – Pontassieve (FI) – Italy www.tecnoware.com
Edition: May 2012 – version: 2.0
No part of this manual may be reproduced, even partially, without the authorisation of TECNOWARE s.r.l.
TECNOWARE s.r.l. reserves the right to change specifications at any time and without notice.
UPS ECO STRIP 0.50 – 0.70 – 0.90 – 1.1 - 1.3 1 User’s manual
Safety Warnings
Read this manual carefully and completely before installing and using the TECNOWARE ECO
STRIP Uninterruptible Power Supply, which, from here after, will also be referred to as UPS.
This manual should be kept close to the UPS and read before the UPS is installed and used. The UPS must be used only by properly trained personnel. To ensure correct and safe
operations, it is necessary that operators and maintenance personnel observe the general safety Standards as well as the specific instructions included in this manual.
Risk of electric shock: do not remove the cover. The UPS contains internal parts, which are at a
high Voltage and are potentially dangerous, capable of causing injury or death by electric shock.
There are no internal parts in the UPS, which are user serviceable. Any repair or maintenance
work must be performed exclusively by qualified technical personnel authorized by TECNOWARE. TECNOWARE declines any responsibility if this warning is disregarded.
Warning to the technical personnel authorized for Service: since internal components are
connected to the batteries, they will remain powered, and therefore dangerous, even after the UPS has been disconnected from AC power mains. Before any repair or maintenance work, disconnect the batteries, by removing the positive cable (red colour) from the positive pole of the battery.
It is compulsory to ground the UPS according to Safety Standards. The AC mains power supply
socket used to power the UPS must have an earth connection.
In the event of AC main power supply failure (when the UPS works in Battery mode), do not
unplug the power supply cable to the UPS to ensure earth continuity to the connected loads.
Since the AC mains power supply cable acts as a separation device, the AC mains power socket
used to supply the UPS and/or the rear side of the UPS must be accessible to easily disconnect the cable in case of dangerous conditions.
Risk of electric shock at the Output lines when the UPS is ON. Risk of electric shock at the Output lines while the unit is connected to the AC utility line. Do not obstruct ventilation slots or holes and do not rest any object on top of the UPS. Do not insert objects or pour liquids in the ventilation holes. Install the UPS indoors, in a protected, clean and moisture-free environment. Do not expose to the direct sun light. Do not keep liquids, flammable gases or corrosive substances near the UPS.
User’s manual 2 UPS ECO STRIP 0.50 – 0.70 – 0.90 – 1.1 – 1.3
1 Introduction
ECO STRIP is an UPS (Uninterruptible Power Supply) specifically designed to protect your computer from any type of irregularities in the AC line (such as black-outs, under or over voltages, micro-interruptions), which often cause damage to your Hardware and Software.
Under normal AC line condition, ECO STRIP filters frequently occurring electrical disturbances (such as transients, spikes, interferences, etc.), thus protecting all devices connected to the outlets, and recharging the batteries in an ideal way. In case of anomaly to the AC line, the UPS continues feeding the protected equipment.
Read this manual carefully before using the ECO STRIP; it includes important safety warnings and useful advices for correct use and installation.
This manual is a guide that enables you to correctly install and use your UPS. This manual includes important SAFETY instructions for the operator, for the UPS correct installation, and gives useful advice on the product and battery maintenance. For any type of problem, please refer to this manual before calling the customer service.
ECO STRIP is constantly being developed and improved: consequently, your unit may differ somewhat from the description contained in this manual.
This manual includes the following models:
ECO STRIP 0.50 (500 VA)
ECO STRIP 0.70 (700 VA)
ECO STRIP 0.90 (900 VA)
ECO STRIP 1.1 (1100 VA)
ECO STRIP 1.3 (1300 VA)
In this manual ECO STRIP will simply be referred to as UPS.
2 General Characteristics
ECO STRIP has all the advanced features, which guarantee maximum reliability and safety:
All functions are controlled by a microprocessor, giving full guarantee of high reliability.
Overload protection both in normal mode and in battery mode.
High performance battery charger, which extends the battery medium life ensuring an optimal recharge.
Start up even if the electrical network is not available.
Automatic restart after an automatic shut down due to a low battery condition once the AC utility power
returns.
Adapts automatically to 50 or 60 Hz input frequency.
UPS ECO STRIP 0.50 – 0.70 – 0.90 – 1.1 - 1.3 3 User’s manual
Visual and acoustic signals indicating operating mode and alarm/fault conditions.
High efficiency
Maximum reliability
Smart design and easy to use
3 Receipt and site selection
Carefully remove the UPS from its packaging, and carry out a meticulous inspection. We recommend keeping the original packaging in a secure place, in case you need to send the UPS for maintenance purposes. In case of transport damage, notify the carrier and dealer immediately.
We recommend paying attention to the below points in order to choose a correct placement for your UPS:
The UPS is designed to operate in a protected environment (e.g. offices). We therefore recommend
installing it in a place with very little or no humidity, dust or smoke.
In all circumstances, see the “Technical Characteristics” chapter for environmental specifications and
check that the selected area meets these specifications.
During normal operation the UPS discharges a minimal amount of heat. So it is necessary to leave at least
20 cm of unobstructed space all around the UPS in order to keep it properly ventilated.
Do not obstruct ventilation holes.
Do not insert objects or pour liquids in the ventilation holes.
Do not rest any object on top of the UPS.
Do not keep liquids, flammable gases or corrosive substances near the unit.
Install the UPS on a properly tiled floor. Avoid the installation on a floor that is not tiled flat.
User’s manual 4 UPS ECO STRIP 0.50 – 0.70 – 0.90 – 1.1 – 1.3