Tecnoclima SR-UT 86, SR-UT 106, SR-UT/K 26, SR-UT/K 36, SR-UT 36 Technical Information Assembly, Use And Maintenance Instructions

...
TECHNICAL INFORMATION
ASSEMBLY, USE AND MAINTENANCE INSTRUCTIONS
HEATING UNITS
WITH ATMOSPHERIC BURNER
1.0
Manual attached to the USE AND MAINTENANCE INSTRUCTIONS of the UT and UT/K series
As to what is not expressly mentioned in this manual, it is valid what is set forth in the manual ASSEMBLY USE AND
MAINTENANCE INSTRUCTIONS of the UT and UT/K series appliances
1
GENERAL INFORMATION
COMPLIANCE AND PIN NUMBER
PRODUCT RANGE
WARRANTY
GENERAL WARNINGS
BASIC SAFETY RULES
DISPOSAL INSTRUCTIONS
Dear Customer, Thank you for choosing a TECNOCLIMA product. This instruction handbook includes instructions and suggestions that shall be complied with for simpler
2.0
installation and to ensure the best use of the appliance.
Thank you.
Tecnoclima S.p.A.
3.0
The machine complies with the Directives, Rules and Regulations listed in the Declaration of Conformity that can be requested to the Producer. The PIN number of the EC certification, if any, is included in the technical data plate.
Throughout this manual, reference is made to the TYPE, to which the TRADE NAME specified in the table is connected:
4.0
TRADE NAME TYPE TRADE NAME TYPE
SR-UT 26 1 SR-UT/K 26 7 SR-UT 36 2 SR-UT/K 36 8 SR-UT 46 3 SR-UT/K 46 9 SR-UT 66 4 SR-UT/K 66 10 SR-UT 86 5 SR-UT/K 86 11
SR-UT 106 6 SR-UT/K 106 12
5.0
The appliance is covered by a specific warranty, whose terms are specified in detail in the warranty certificate or in the delivery contract, which should be read with great care.
6.0
As for general warnings, refer to the user’s manual of the UT and UT/K series.
Any operation on the appliance shall be performed only by qualified and skilled workers.
7.0
As for basic safety rules, please refer to the user’s manual of the series UT and UT/K
8.0
The appliance contains electric components; therefore it shall not be disposed of as household waste. As for disposal methods, refer to the local laws on special waste.
2
GENERAL INFORMATION
DESCRIPTION
STRUCTURE
2
1
4
6
5
3
7
These machines are heating units to be used for air heating. They are essentially thermal units of exchange between the combustion products of an atmospheric burner and the air flow generated by a ventilation unit not included in the scope of supply. The air to be heated is sucked by the ventilation unit and, when it laps the hot surface of the heat exchanger, it is heated - increasing its temperature; then it can be distributed both directly and through proper channels. Trough this heating system, the plant costs can be remarkably reduced and a reliable operating economy can be reached.
9.0
WARNING
!
The heating sections type 1-2-3-4-5-6 are designed to be installed indoors, and protected from atmospheric agents. Heating units type 7-8-9-10-11-12 have been conceived to be installed outdoors.
10.0
Legend of the components:
1. Air inlet flange
2. Smoke exhaust
3. Electric panel
4. Atmospheric burner
5. Lower frame
6. Air outlet flange
7. Heat exchanger
3
GENERAL INFORMATION
VOLUME AND WEIGHT
TYPE 1-2-3-4-7-8-9-10:
(This drawing represents the outdoor installation design)
11.0
TYPE 1-7 2-8 3-9 4-10
A mm 460 460 460 460 B mm 460 460 460 460 C mm 840 840 840 ? D mm 464 464 464 464 E mm 435 515 695 940 F mm 464 464 464 464 G mm 350 460 655 900 H mm 27 27 27 27
TYPE 1 2 3 4
Net weight kg 95 105 130 155
TYPE 7 8 9 10
Net weight kg 105 115 140 170