We thank you for preferring one of our machines, an innovative, modern and high-quality product which will ensure you
wellness, noiselessness and safety for a long time, especially if you rely on TECHNOCLIMA Technical Support Service
which is specifically instructed and trained to maintain your unit at the maximum efficiency level with lower operating costs
and which has
original spare parts available in case of need.
This instruction manual contains important indications and suggestions which must be followed for a simpler installation and
the best possible use of the unit.
The unit is covered by a SPECIFIC WARRANTY, taking effect from the purchase date which must be proved by the user.
Should he not be able to prove it, the warranty will take effect from the appliance manufacture date. The warranty conditions
are detailed in the WARRANTY CERTIFICATE provided with the equipment.
MAKE SURE this instruction manual IS ALWAYS KEPT TOGETHER WITH THE APPLIANCE, so that the user, installer
and maintenance qualified personnel can refer to it.
If you sell or transfer the appliance to another proprietor or if you move and leave the appliance, make sure that the
instruction manual always accompanies the unit, so that the new proprietor and/or installer can refer to it.
GENERAL DIRECTIONS...................................................................................................................................................4
FUNDAMENTAL SAFETY RULES..................................................................................................................................... 5
TECHNICAL DATA - WEIGHTS.........................................................................................................................................7
ELECTRIC BOARD AND MULTIFILAR WIRING DIAGRAM.............................................................................................. 9
CONTROL PANEL...........................................................................................................................................................15
SWITCHING ON AND OFF.............................................................................................................................................. 17
INACTIVITY FOR A LONG PERIOD INACTIVITY FOR A LONG PERIOD...................................................................... 19
UPON RECEIVING THE PRODUCT ............................................................................................................................... 20
HANDLING AND TRANSPORT....................................................................................................................................... 20
ENABLING THE “SO” AND “SEI” CONTROLS”............................................................................................................... 29
FILLING AND EMPTYING THE SYSTEM........................................................................................................................ 29
RECOMMENDED WORKING CONDITION S........... ........................................................................................................ 30
WORKING LIMITS....................................................................................................... ....................................................30
PREPARETION
PREPARATION FOR FIRST COMMISSIONING............................................................................................................. 31
FIRST COMMISSIONING................................................................................................................................................31
SWITCHING THE EQUIPMENT ON AND OFF............................................................................................................... 32
CHECKS DURING AND AFTER THE FIRST COMMISSIONING.................................................................................... 35
INACTIVITY FOR A LONG PERIOD................................................................................................................................35
Symbols with the following meanings are used in some parts of the manual:
CAUTION = For actions requiring special care and adequate training.
FORBIDDEN = For actions which SHOULD NEVER be done.
3
IDENTIFICATION
The unit can be identified through:
- - Rating plate
It bears the technical and performance data of the equipment.
Should this plate be damaged or mislaid, ask your local Technical Support Service for a duplicate.
Tampering with the rating plate, removing it or whatever else does not allow a sure identification of the product hinder
any installation or maintenance interventions.
GENERAL DIRECTIONS
After unpacking the appliance, check it for integrity and completeness. Should the content not match your order, please contact the retailer
who sold the equipment.
The equipment must be installed by a qualified company which, at the end of the work, must provide the proprietor with a declaration of
conformity stating that the installation complies with the best practice and the applicable national and local regulations, as well as the
indications of this instruction manual.
These appliances were made for room air heating and/or conditioning and must be destined for this use consistently with their performance
characteristics.
The manufacturer does not assume any contractual or extra-contractual liability for damages caused to people, animals or things by
installation, adjustment and maintenance errors or improper use.
In case of water leakage, turn OFF the main system circuit breaker and close the water taps.
Immediately call the Technical Support Service or professionally qualified personnel and do not personally intervene on the equipment.
The appliance contains refrigerant gas R 410A; act carefully in order not to damage the gas circuit and the finned coil. In case of refrigerant
leakage, turn OFF the main system circuit breaker. Immediately call the Technical Support Service or professionally qualified personnel and
do not personally intervene on the equipment.
The appliances must be exclusively equipped with original accessories. The manufacturer is not responsible for any damages resulting from
the improper use of the appliance and the use of non-original accessories and materials.
The references to laws, regulations, directives and technical standards mentioned in this manual have a mere informational purpose and are
valid at the printing date of the same. The manufacturer cannot be bound towards third parties on account of new regulations or
amendments to those already in force.
The installations to be made (gas piping, electric power supply, etc.) must be adequately fixed and avoid the risk of stumbling.
The manufacturer is responsible for the conformity of his product to the laws, directives and standards which were in force at the time of
marketing.
The knowledge and observance of regulations and standards about the system designing, installation, operation and maintenance are at the
exclusive charge of the designer, installer and user according to their spheres of competence.
4
The manufacture is not held responsible for the non-observance of the instructions contained in this manual, for the consequences of an y
unexpected operation or for any translations from which wrong interpretations may arise.
This appliance must be installed in accordance with the applicable national and local regulations and must be only used in a sufficiently
ventilated environment. Carefully read the instructions before installing and operating this equipment.
Should the unit be connected in parallel to a boiler, close the chiller cocks during the boiler operation.
The temperature of the circulating water inside the chiller should never exceed 60°C.
If you are not going to use the equipment for a long time, please do the following:
– Turn OFF the main system circuit breaker
– Close the water taps
– If there is danger of freezing, make sure an antifreeze liquid has been added to the system, otherwise empty the system
This instruction manual is an integral part of the appliance, therefore it must be kept with care and ALWAYS accompany the appliance if it is
transferred to another proprietor or user or moved to another system.. Should this manual be damaged or mislaid, ask your local Technical
Support Service for a new copy.
The repair or maintenance work must be carried out by the Technical Support Service or qualified personnel according to the prescriptions of
this manual. Do not alter or tamper with the appliance as this may lead to dangerous situations, and the manufacturer of the ap pliance will
not be held responsible for any damages caused.
.
Under adverse visibility conditions, use lighting devices enabling a perfect vision of all parts and components.
The refrigerant fluid contained in the refrigerating circuit is R-410A and it is not classified as dangerous in accordance with directive
1999/45/EC and relevant amendments.
Avoid high steam concentrations which may cause headache, vertigo, somnolence, nausea and other troubles.
In case of skin contact with the liquid, there is a residual risk of freezing through fast evaporation. Seek medical advice.
In case of inhalation, breath fresh air. Administer oxygen if breathing is difficult. Seek medical advice.
In case of eye contact, immediately flush with running water for at least 15 minutes. Seek medical advice.
The refrigerant fluid must be disposed of through authorized waste-disposal companies. In any case, the fluid must be recovered in proper
storage tanks.
FUNDAMENTAL SAFETY RULES
We remind you that the use of products using electric power, gas or gas oil entails the observance of some fundamental safety
rules, like the following:
The use of the appliance by children and unattended disabled people is prohibited.
Do not touch the appliance while barefoot and with wet or humid body parts
Do not perform any cleaning or maintenance before disconnecting the appliance from the mains (by turning OFF the main system circuit
breaker).
The safety and setting devices should not be altered without the appliance manufacturer’s consent and indications
Do not pull, tear or twist the electrical cables on the appliance, although this is disconnected from the mains.
Do not insert sharp objects through the air intake and supply grilles.
Do not open the equipment’s internal part access doors without first turning off the main system circuit breaker.
Do not abandon or leave to the children’s reach the packing material (cardboard, iron bands, plastic bags, etc.) as this is a potential source
of danger.
Do not install the appliance in environments with an aggressive atmosphere
Do not place any objects onto the equipment, nor slide them through the grille.
Do not use any adapters, multiple-outlet sockets or extensions for the electrical connection of the appliance.
Do not distribute this product in different countries, since it must be modified as to technical documentation and layout.
Do not perform any maintenance before disconnecting the appliance from the mains (by turning OFF the main all-pole system circuit
breaker).
.
.
.
5
EQUIPMENT DESCRIPTION
The units are divided into two families:
– HEAT PUMPS, BESST series: some available with single-
phase power supply, others with three-phase power
supply, capable of producing both hot water for heating
and cold water for cooling household, residential and
industrial environments.
– HEAT PUMPS, BESST/R series: also av ailable with three-
and single-phase power supply, capable of producing both
hot water for heating and cold water for cooling household,
residential and industrial environments and provided with
supplementary electrical resistor for correct operation
even under very critical weather conditions.
They are used in combination with terminal or fan-coil units in small
and medium-large systems.
They are designed for outdoor installation and the used materials
have been selected to meet this special requirement.
They use a scroll-type rotating compressor, mounted on
antivibration supports inside an adequate compartment, and
electronically-controlled variable-speed helical fans, which
ensure particularly noiseless operation. For three-phase
versions, a phase monitor is standard supplied to check the
proper compressor rotation.
The AISI 318 stainless steel plate heat exchanger, on utility end,
is insulated with an anti-condensation coating and complete with
a flow controller.
The units are equipped with various safety devices, such as
pressure-switches, hydrometer, sensors, specific automatic
switches and phase monitor (only for three-phase units). An
electronic, microprocessor-controlled equipment supervises the
operation. They are also provided with an inertial storage tank
which is integrated into the unit as a standard.
Heating capacity
Power input
Heating capacity
Power input
Heating capacity
Power input
Heating capacity
Power input
Heating capacity
Power input
(1)
(1)
(2)
(2)
(3)
(3)
(4)
(4)
(5)
(5)
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
1/9 2/10 3/11 4/12 5/13 6/14 7/15 8/16
6,8 8,3 11,0 15,0 19,9 22,2 28,0 37,2
1,74 2,11 2,81 3,61 4,28 4,83 6,48 8,44
5,9 7,2 9,5 13,0 16,6 18,9 23,8 31,7
1,78 2,20 2,90 3,67 4,33 4,86 6,55 8,52
5,0 6,2 8,0 10,8 13,5 15,4 19,2 25,8
1,79 2,26 2,97 3,73 4,36 4,88 6,66 8,63
6,6 8,1 10,6 14,4 18,4 21,0 26,4 34,8
2,14 2,68 3,50 4,49 5,23 5,96 7,84 10,18
5,6 7,1 9,3 12,6 15,9 18,1 22,6 30,0
2,16 2,77 3,60 4,60 5,26 5,99 8,00 10,33
Cooling capacity
Power input
Cooling capacity
Power input
Cooling capacity
Power input
Cooling capacity
Power input
(6)
(7)
(8)
(9)
(6)
(7)
(8)
(9)
kW
kW
kW
kW
kW
kW
kW
kW
7,5 10,3 13,0 17,8 23,6 27,2 33,9 45,1
1,80 2,28 2,93 3,89 4,96 5,67 7,04 9,05
6,9 9,3 11,8 17,0 21,3 24,6 31,0 40,4
2,00 2,72 3,46 4,56 5,78 6,60 8,13 10,51
6,0 8,2 10,2 14,1 17,9 21,0 26,9 34,9
1.76 2,34 3,01 3,93 5,03 5,69 7,05 9,19
5,3 7,1 9,3 13,0 17,0 19,5 24,7 32,2
2,04 2,81 3,58 4,65 5,85 6,66 8,22 10,71
Nominal water flow-rate
(10)
Water fitting diameter inches
Tank capacity - liters
Supporting resistor *
Supply voltage
Protection degree
Helical fan
Nominal air flow-rate
Sound level
(11)
R410A refrigerant charge
Loadless weight
(1) outdoor air +7°C, water 35 – 30°C.
(2) outdoor air +0°C, water 35 – 30°C.
(3) outdoor air -7°C, water 35 – 30°C.
(4) outdoor air +7°C, water 45 – 40°C.
(5) outdoor air +0°C, water 45 – 40°C.
(6) outdoor air +30°C, water 18 – 23°C.
(7) outdoor air +35°C, water 18 – 23°C.
(8) outdoor air +30°C, water 7 – 12°C.
(9) outdoor air +35°C, water 7 – 12°C.
(10) ref. outdoor air 0°C, water 35-30°C
(11) Sound level measure d under free-field conditio ns at 1.5 meters from fan front and 1.5 meters from the ground .