Teclumen Spot 575 TM3 User Manual

Spot 575 TM3 Spot 575 TM3
GB
User Manual Rel 1.0
Le informazioni contenute in questo documento sono state attentamente redatte e controllate. Tuttavia
non è assunta alcuna responsabilità per eventuali inesattezze. Tutti i diritti sono riservati e questo
documento non può essere copiato, fotocopiato, riprodotto per intero o in parte senza previo consenso
Teclumen si riserva il diritto di apportare senza preavviso cambiamenti e modifiche estetiche , funzionali o
di design a ciascun proprio prodotto. Teclumen non assume alcuna responsabilità sull’uso o
sull’applicazione dei prodotti o dei circuiti descritti.
The information contained in this publication has been carefully prepared and checked. However, no
responsibility will be taken for any errors. All rights are reserved and this document cannot be copied,
photocopied or reproduced, in part or completely, without prior written consent from Teclumen Teclumen reserves the right to make any aesthetic, functional or design modifications to any of its products without prior notice. Teclumen assumes no responsibility for the use or application of the
products or circuits described herein.
Les informations contenues dans le présent manuel ont été rédigées et contrôlées avec le plus grand
soin. Nous déclinons toutefois toute responsabilité en cas d'éventuelles inexactitudes. Tous droits
réservés. Ce document ne peut être copié, photocopié ou reproduit, dans sa totalité ou partiellement,
sans le consentement préalable de Teclumen
Teclumen se réserve le droit d'apporter toutes modifications et améliorations esthétiques, fonctionnelles
ou de design, sans préavis, à chacun de ses produits. Teclumen décline toute responsabilité sur
l'utilisation ou sur l'application des produits ou des circuits décrits.
Las informaciones contenidas en este documento han sido cuidadosamenteredactadas y
controladas. Con todo, no se asume ninguna responsabilidad por eventuales inexactitudes.
Todos los derechos han sido reservados y este documento no puede ser copiado, fotocopiado
o reproducido, total o parcialmente, sin previa autorizaciónescrita de Teclumen
Teclumen se reserva el derecho a aportar sin previo aviso cambios y modificaciones de
carácter estético, funcional o de diseño a cada producto suyo. Teclumen no se asume
responsabilidad de ningún tipo sobre la utilización o sobre la aplicació
n de los productos o de los circuitos descritos.
ARC 1200
Spot 575 TM3
2
ARC 1200
3
INDEX:
1- TECHNICAL FEATURES 4 2- IMPORTANT SAFETY INFORMATION 5
2.1 Fire prevention
2.2 Prevention of electric shock
2.3 Protection against ultraviolet radiation
2.4 Safety
2.5 Level of protection against the penetration of solid and liquid matter
3- MOUNTING THE LAMP 6
3.1 Lamp alignment
4- VOLTAGE AND FREQUENCY 7 5- INSTALLATION 7
5.1 Safety cable
5.2 Protection against liquids
5.3 Movement
5.4 Risk of fire
5.5 Forced ventilation
5.6 Ambient temperature
6- MAINS CONNECTION 8
6.1 Protection
7- DMX SIGNAL CONNECTION 9
7.1 DMX Addresses
7.2 Selecting the DMX address
8- DISPLAY FUNCTIONS 11 9- AUTOMATIC MODE 14
9.1 Game P
9.2 Rec Mode
10- PAN & TILT SPEED 15 11- FANS SPEED 12- ERROR MESSAGES 13- HIDDEN MENU 16 14- OPENING UP THE PROJECTOR HOUSING 17 15- REPLACING GOBOS 16- PERIODIC CLEANING 18
16.1 Lenses and reflectors
16.2 Fans and air passages
17- PERIODIC CONTROLS 18- DMX PROTOCOLS 19 19- GOBO WHEEL 30 20-COLOUR WHEEL 31 21- MOTORS CONTROL CARD 32 22- PAN & TILT CARD 33 23-CABLES RESEND CARD 24-DISPLAY CARD 25- LAMP ON-OFF CONTROL CARD 26- WIRING DIAGRAM 34
Spot 575 TM3
ARC 1200
4
1- TECHNICAL FEATURES
The Spot 575 TM3 is fitted with a Philips MSR 575/2 discharge lamp (GX9,5 lampholder base), with a colour temperature of 7,200 °K and a luminous flux of 49,000 Lumens. Duration is 750 hours, with replacement recommended before 1000 hours Other recommended lamps: Philips 575 MSD (6.000K°-49.000 Lumens-3.000 hours) The unit incorporates: Motorized Focus system Zoom (3 selectable beam aperture angles 11° / 15° / 18° with auto-focus) Dimmer (emitted light is controlled by progressive and linear dimming). Shutter (instantaneous shutter opening/closure) Strobe: mechanical strobe effect (frequency variable from 0.85 flashes/sec to 10 flashes/sec). Gobo wheel (7 indexable 16 bit gobos + open) Colour wheel (8 colours + open) Prism (indexable 3 facet prism rotating in both directions) Frost Filter Electronic or magnetic ballast Pan: 540° in 3.9 seconds (8 or 16 bit) with auto repositioning system Tilt: 320° in 2.6 seconds (8 or 16 bit) with auto repositioning system USITT Standard DMX 512 input 20 DMX channels 4 -eight digit- LED display with 4 buttons 2 XLR connectors (In and Out) with 3 and 5 pins selectable by user Power supply Electronic ballast: Universal power supply 90 - 245 V (50/60 Hz) Electromagnetic ballast: 230 V 50-60 Hz(Standard) On request: 100 V 50-60 Hz /120 V 60 HZ / 208 V 60 Hz Power consumption: 750 W. Remote Lamp on/off via DMX Operating ambient temperature -10° / 40° Weight 26 Kg (Spot 575 TM3 E.B.)
Dimensions (HxDxL) Projector (670x450x470) Weight 26 Kg
Packing Dimensions (HxDxL) 800 x 550 x 440 mm Weight
33.3 Kg
Spot 575 TM3
ARC 1200
5
2- IMPORTANT SAFETY INFORMATION
2.1 Fire prevention:
The use of any other alternative lamp is not recommended and will null and void the fixture's warranty.
-Never locate the fixture on any flammable surface.
-Minimum distance from flammable materials: 1 MT.
-Minimum distance from the closest illuminable surface: 2 MT.
-Replace any blown or damaged fuses only with fuses of identical value. Refer to the wiring diagram if there is any doubt.
-Connect the projector to mains power via a thermal magnetic circuit breaker.
2.2 Prevention of electric shock:
-High voltage is present inside the unit. Unplug the unit prior to performing any function which involves touching the inside of the moving head, including lamp replacement.
-The level of technology present in the Spot 575 TMrequires the assistance of specialised personnel for all servicing. Please refer to an authorised Teclumen service centre.
-A good earth connection is essential for proper functioning of the projector.
-Never connect the unit without proper earth connection.
-The fixture should be located in places with a good air ventilation.
2.3 Protection against ultraviolet radiation:
-Never turn on the lamp if any of the lenses, filters or ABS covering is damaged. Their respective shielding functions will only operate efficiently if they are in perfect working order.
-Never look directly the lamp when it is on.
2.4 Safety:
-The projector should always be installed with bolts, clamps and other tools that are capable of supporting the weight of the unit.
-Always use a second safety cable to sustain the weight of the unit in case of the failure of the main fixing point.
-The external surface of the unit, at various points, may exceed 70°C. Never handle the unit until at least 10 minutes have elapsed since the lamp was turned off.
-Always replace the lamp if any physical damage is evident.
-Never install the fixture in an enclosed area lacking sufficient air flow. The ambient temperature should not exceed 40°C.
-A hot lamp may explode, so always wait for at least 10 minutes prior to attempting to replace the lamp.
-Always wear suitable hand protection when handling the lamp.
2.5 Level of protection against the penetration of solid and liquid matter:
-The projector is classified as an ordinary appliance and its protection level against the penetration of solid and liquid matter is IP 20.
Spot 575 TM uses a Philips 575 MSR/2 or MSD
Spot 575 TM3
3- MOUNTING THE LAMPS
Warning: Switch off the unit before replacing the lamp.
1) Using a screwdriver, remove the 3 screws A,B, C, (photo 1) which fix the lamp holder.
2) Remove the lamp holder assembly (photo2).
3)Insert the lamp (photo 3). The lamp used on Spot 575 TM3 is made in quartz glass and should be handled with care. Always follow the instructions supplied in the lamp's packaging. Never touch the glass directly but use the tissue provided in the lamp's packaging. The GX9,5 lamp socket is symmetrical. DO NOT USE UNDUE FORCE ON THE GLASS. In case of difficulty, read again the instructions and repeat the procedure.
4) Replace the lamp assembly and tighten the screws A,B,C, which were previously removed (photo4).
3.1 Lamp alignment
Attention: we recommend to align the lamp in the optical system to avoid overheating of the dichroic filters and other components inside the unit.
Alignment is carried out using the 3 adjusters X, Y and Z. During this operation you must have a uniform luminosity all around the projected area.
Philips 575 MSR/2 Power 575W Luminous flux 49,000 lm Colour temperature 7.200°K Lampbase GX9,5 Rated life 1,000 hours
6
Photo 2Photo 1 Photo 4Photo 3
Philips 575 MSD Power 575W Luminous flux 43,000 lm Colour temperature 6.000°K Lampbase GX9,5 Rated life 3,000 hours
Photo 5
Spot 575 TM3
4- VOLTAGE AND FREQUENCY
The Spot 575 TMwith electronic ballast can operate at 90-245 VOLT 50 or 60 Hz. The Spot 575 TMwith electromagnetic ballast can operate at
5- INSTALLATION
Spot 575 TMmay be either floor or ceiling mounted. For floor mounting installations, the Spot 575 TMis supplied with four rubber mounting feet on the base. For ceiling mounted installations, we reccomend the use of appropriate clamps to fix the unit to the mounting surface. The supporting structure from which the unit is hung should be capable of bearing the weight of the unit, as should any clamps used to hung it. The structure should also be sufficiently rigid so as not to move or shake whilst the Spot 575 TMis moving. Four quarter turn fast locks placed on the base of the units,allows by using the two fast lock C clamps provided in the box, to fix the unit in any position. .
5.1- Safety cable
We recommend the use of a safety cable or chain connected to the Spot 575 TMand to the suspension truss in order to avoid the fixture accidentally falling should the main fixing point fail. Make sure that the iron cable or chain can bear the weight of the entire unit. You may attach the safety chain to the two holes (A) located on the base of the fixture, as shown in the picture below.
5.2- Protection against liquids
The projector contains electric and electronic components which should under no circumstances come into contact with oil, water or any other liquid. The proper unit functioning would be compromised should this occur.
230 V 50-60 Hz(Standard)
On request: 100 V 50-60 Hz /120 V 60 HZ / 208 V 60 Hz
7
A
Spot 575 TM3
5.3- Movement
The projector has a maximum movement of 540° for Pan and 270° for Tilt. DO NOT place any obstructions in the path of the projector's movement.
5.4- Risk of fire
Each fixture produces heat and must be installed in a well-ventilated place. The minimum recommended distance from flammable material is 1 MT. Minimum distance from the object being illuminated is 2 MT.
5.5- Forced ventilation
You will note, on inspection, that the unit features various air inlets and cooling fans located on both the base and head of the fixture. These should, under no circumstances, be blocked or obstructed whilst the projector is in operation. Doing so could cause the fixture to seriously overheat thereby compromising its proper operation.
5.6- Ambient temperature
The projector should never be installed in places that lack a constant air flow. The ambient temperature should NOT exceed 40°C.
6- MAINS CONNECTION
Spot 575 TMwith electronic ballast operate at 90-245 VOLT 50-60 Hz. Spot 575 TMwith electromagnetic ballast operate at 230 VOLT 50-60 Hz
Prior to connecting the unit to your mains supply, ensure that the model in your possession correctly matches the mains supply available. For connection purposes, ensure that your plug is capable of supporting 6,3 amps at 208-230V, Or16 amps at 100-120 V Strict adherence to regulatory norms is strongly recommended.
6.1- Protection
The use of a thermal magnetic circuit breaker is recommended for each Spt 575 TM3. A good earth connection is essential for the correct operation of the projector.
7- DMX SIGNAL CONNECTION
The unit operates using the digital DMX 512 (1990) signal. Connection between the mixer and the projector or between projectors must be carried out using a two pair screened ø 0.5 mm cable and a CANNON XLR 5 or 3 pins connector.
(On request: 100 V 50-60 Hz /120 V 60 HZ / 208 V 60 Hz)
8
540°
27
Electronic ballast 90-245V 50 / 60Hz Electromagnetic ballast 230 V 50/60 Hz (standard)
On request: 100 V 50-60 Hz 120 V 60 HZ / 208 V 60 Hz
Spot 575 TM3
Ensure that the conductors do not touch each other.Do not connect the cable ground to the XLR chassy The plug housing must be isolated. Connect the mixer signal to the DMX IN projector plug and connect it to the next projector by connecting the DMX OUT plug on the first projector to the DMX IN plug of the second one. In this way, all the projectors are cascade connected. NB. If the display showing the DMX address flashes, then one of the following errors has occurred:
- DMX signal not present
- DMX address not valid
- DMX reception problem
The standard configuration of the Spot 575 TM3 is with XLR 5 pins connection. To convert to an XLR 3 pins configuration proceed as follows:
1) Remove the 2 screws fixing the display cover panel to the unit (photo 1).
2) Remove the screws that fix the XLR connectors to the panel (photo 2).
3) Rotate the electronic card by 180° (photo 3).
4) Place the 3 pins XLR connectors in the special holes and close.
For Installations where long distance DMX cable connections are needed,we suggest to use a DMX terminator. The DMX terminator is a male XLR 3-5 pins connector with a 120 ohm resistor Between pin 2 and 3. The DMX terminator must be plugged into the last unit (DMX out panel connector) of the DMX line.
Photo 2Photo 1 Photo 3
5
3
4 2
1
1=GND 2=DATA­3=DATA+
CONTROLLER STANDARD DMX 512
1
2
3
5
4
OUT
120 ohm
PIN 3
PIN 2
PLACE A 120 OHM RESISTOR BETWEEN PIN 2
AND 3 OF A MALE XRL CONNECTOR AND PLUG IT
INTO THE DMX OUT PANEL CONNECTOR OF THE
LAST UNIT CONNECTED TO THE DMX LINE
9
Spot 575 TM3
7.1-DMX Addresses
Spot 575 TM3 can be used in two different modes: 16 or 20 DMX (default) channels. If you want to use the Spot 575 TM3 in 16 channels mode, select the 16 CH mode from the MODE
menu and set the following addresses on the mixer: Projector 1 A001
Projector 2 A017 If you want to select the next projector, just add “16” Projector 3 A033
….. A…. projector 6 A081
If you want to use the Spot 575 TM3 in 20 channels mode, select the 20 CH mode from the MODE menu and set the following addresses:
Projector 1 A001 Projector 2 A021 If you want to select the next projector, just add “20”
Projector 3 A041 ….. A…. Projector 6 A101
7.2-Selecting the DMX address
1) Press the UP-DOWN key until you reach the required DMX channel. The numbers on the display will start to flash (but the new DMX address hasn't yet been set).
2) Press ENTER to confirm your selection. The numbers on the display will stop flashing and the projector is now setted to the new DMX address.
TRICKS: if you keep pushed the UP or DOWN keys, the channels are calculated more quickly and you get a faster selection.
10
Spot 575 TM3
DMX IN
DMX OUT
DISPLAY
MAINS
Electronic ballast
90-245V 50 / 60Hz
Electromagnetic ballast
230 V 50/60 Hz (standard)
On request: 100 V 50-60 Hz
120 V 60 HZ / 208 V 60 Hz
8- DISPLAY FUNCTIONS
11
MENU
ENTER
DOWN
UP
DISPLAY FUNCTIONS
The Spot 575 TM3 display panel shows all the available functions . Using these functions, it is possible to change some of the parameters and add some functions. Changing the Teclumen setting can vary the functions of the unit so that it does not respond to the DMX 512 used to control it. Carefully follow the instructions below before carrying out any variations or selections. NOTE: the symbol shows which key has to be pushed to obtain the desired function.
Up-DownMENU ENTERUp-Down
PAN MOVEMENT INVERSION To reverse Pan movement from left to right and vice versa
Up-Down
Counterclockwise
Clockwise
Up-DownMENU ENTERUp-Down
TILT MOVEMENT INVERSION To reverse Tilt movement from bottom upwards and vice versa
Up-Down
Counterclockwise
Clockwise
Up-DownMENU ENTER
DMX MODE To select DMX mode : 20-16 channels
20 CHANNELS
(Pan & Tilt 16 bit)
16 CHANNELS
(Pan & Tilt 16 bit)
Up-Down
Up-Down
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
Up-Down
MENU
ENTERUp-Down
REVERSE DISPLAY Reverses display's reading depending on the mounting position (On the ground or suspended).
Up-Down
Floor
position
Suspension
position
Up-DownENTER
Up-DownENTER
DISPLAY STAND BY To turn off the display (after 5 seconds) Or leave it always on.
Display OFF
Display
always ON
ENTER
ENTER
ENTER
ENTER
Spot 575 TM3
Loading...
+ 25 hidden pages