Technotherm VPS-Design B 1200 H RF, VPS-Design B 2000 RF, VPS-Design W 1200 H RF, VPS-Design M 1200 H RF, VPS RF 1000 Installation And Technical Manual

...
D
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE
Edition: 01/18
Id_Nr.911 361 911
Installation and technical manual
VPS-Design Wall mounting
GB
VPS-Design B 1000 – 2000 RF
VPS-Design W 1000 – 2000 RF VPS-Design M 1000 – 2000 RF
VPS-Design B/W/M 1200 H RF
2
Edition: 01/18
Manual
VPS-Design
GB
1. For your safety
This appliance is intended for normal household use and not for use for vehicles or on board ships or aircrafts.
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Children of less than 3 years should be kept away unless continuously supervised.
Children aged from 3 years and less than 8 years shall only switch on/off the appliance provided that it has been placed or installed in its intended normal operating position and they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children aged from 3 years and less than 8 years shall not plug in, regulate and clean the appliance or perform user maintenance.
3
Edition: 01/18
Manual
VPS-Design
GB
CAUTION — Some parts of this product can become very hot and cause burns. Particular attention has to be given where children and vulnerable people are present.
Make sure that your supply rating corresponds to what specified on the rating plate: 230V~, 50Hz.
During function, place the heater in a safe position:
- at least 1m far from inflammable objects or furnitures;
- leaving not less than 1m of free space in front of the heater;
- not located immediately below a socket­outlet.
Do not leave animals or children touch or play with the appliance.
Do not use the heater in rooms with explosive gas or while using inflammable solvents or varnish or glues.
If the cordset is damaged and you have to change it, do not do the job yourselves! Take the product to an after sales authorised repair centre or to a person with similar skill and knowledge, in order to avoid any risk of danger.
The appliance must be positioned so that the plug is always accessible.
Do not mount the product on walls made of synthetic material.
4
Edition: 01/18
Manual
VPS-Design
Warning! this device has to be grounded
This device may only be operated using alternating current and the operating voltage indicated
on the power rating plate
Nominal Voltage 230V AC, 50 Hz
Protection Class I
Degree of Protection IP 24
Room Thermostat 7°C till 30°C
3.1 User Manuel VPS RF Model
3.1.1 Setting the Room Thermostat
Press the receiver button for more than 3 seconds, until the indicator light begins to flash. Subsequently press the transmitter key in the configuration mode. (see User Manual Receiver) As soon as the indicator light stops flashing the two products are assigned.
3.1.2 Setting the sender
Press the receiver button for at least 3 seconds until the indicator light starts flashing. Two modes of operation are possible.
Slow flashing: On\Off switch Fast flashing: instigator
To switch the mode again, press the key briefly. Take the transmitter into the Configuration mode (see user manual transmitter). Check that the indicator light is no longer flashing.
Application Example
The use of a room thermostat in combination with a opening detector is ideal, because the opening detector will detect if a window is open and will automatically switch to frost protection. By pressing the receiver button for approximately 10 seconds, you can change the relay´s setting. You know the setting is changed as soon as the signal light stops flashing.
3.1.3 Deleting Allocations
To delete the setting simply press the receiver key for approximately 30 seconds until you see the receiver light flash briefly. All transmitters are now deleted.
GB GB
5
Edition: 01/18
Manual
VPS-Design
3.1.4 Receiver RF- Technical Specifications
Power Supply 230 V, 50 Hz +/-10%
Protection Class II
Expenditure : 0,5 VA
Switching capacity max.: 16 A 230 Veff Cos j =1 or max. 300 W with lighting control
Radio Frequency 868 MHz (NormEN 300 220),
Radio Range up to 300 m in an open field, indoors up to ca. 30m, depending on the
construction of the building and the electromagnetic interference
Maximal Number of receivers: 8
Mode of operation: type 1.C (Micro-disconnection)
Operating Temperature: -5°C to +50°C
Storage Temperature: -10 °C +70°C
Dimensions: 120 x 54 x 25 mm
Degree of Protection : IP 44 - IK 04
To be installed in average polluted Areas
WARNING
Do not install this device in areas that present an explosion hazard like a garage. Remove all protective coverage before turning on the device. When using the device for the first time you might detect a strong odor. This is no reason for concern; it is caused by residues of production and will disappear shortly.
The rising heat may cause stains on the ceiling, however this phenomena can be caused by any other heating device as well. Only a qualified electrician may open or remove the device from the power supply.
4. Maintenance
Before cleaning the device be sure to turn it off. To clean use a damp towel and a mild detergent.
5. Assembly instruction
This Manual is very important and has to be kept at a safe place at all times. Be sure to hand this manual to any other succeeding owner of the device.
The device is an electrical heater that was designed and intended to be mounted to walls. The device comes with a power plug that has to be plugged into an outlet.
The device is designed to be connected to 230V (nominal) alternating current (AC).
6
Edition: 01/18
Manual
VPS-Design
5.1 Wall Installation
When installing the device, the safety distance must be strictly adhered to, so that flammable materials can not ignite. Install the device to a wall which is heat resistant up to 90 ° C.
• Due to possible fire hazard the safety distances are observed during assembly:
Side walls of the heater to any masonry: 5 cm Side walls of the heater to combustible materials: 10 cm Distance radiator to the floor: 25 cm arranged spaced upper radiator limit to about components or covers (. Eg window):
flammable 15 cm nonflammable 10 cm
To prevent inflammable materials from catching fire be sure to keep the prescribed safety distance when installing the device. Mount the device to a wall that is fireproof up to 90 °C.
The safety distance to the floor should be 25 cm, and at least 10 cm to all other devices. Furthermore there has to be safety distance of approximately 50 cm between the ventilation grille, windowsills, roof slopes and ceilings.
If you want to install the device in your bathroom, be sure to keep it out of reach for people taking a shower or a bath.
When mounting the device to the wall, be sure to keep to the dimensions as indicated in the illustration on page 11. Drill two or three (
if available) 7 mm holes and attach the corresponding plug. Then screw the 4
x 25 mm screws into the holes, leaving a distance of 1-2mm between the head of the screw and the wall.
Hang the device in the two or three fittings and tighten it down. See also the additional mounting information at the following pages!
Attention: The models of VPS-Design are only used by wall mounting!
5,2.
Installation of Electricity
The device was developed for an electrical voltage of 230 V(nominal) and an alternating current of (AC) 50 Hz. The electrical installation may only be performed according to the user manual and only by a qualified Electrician. The device was designed to be used with termination and the connection cable has to be plugged into an appropriate socket at all times. (Notice Permanent cables may not be used)The distance between the receptacle and the device hast to be at least 10cm. The connection line may not touch the device at any time
GB
7
Edition: 01/18
Manual
VPS-Design
5.3 Mounting to the wall
Model
Power
[Watt]
With A High B Deep C [mm] D [mm]
E
[mm] F [mm] G [mm} H [mm]
I
Weight
[kg]
VPS RF
1000
1000 750 450 85 442 140 375 250 115 375 15
VPS RF
1200
1200 750 450 85 442 140 375 250 115 375 15
VPS
RF1500
1500 1050 450 85 740 140 375 250 115 525 20
VPS RF
2000
2000 1050 450 85 740 140 375 250 115 525 20
VPS H 1200
1200
450
1054
85
210
87
984
250
100
223
17
8
Edition: 01/18
Manual
VPS-Design
Additional mounting information
1) Drill three holes of 7mm and fix the wall bracket. Screw in the three 4 x 25 mm screws into the wall
2) Click the heater first at the top into the wall bracket and then at the bottom. The heater will be fixed “automatically”.
wall bracket: to be fixed
with 3 screws
Remove the heater from the heel
1) Push with the screwdriver the heel down
2) Pull the heater away from the heel
Wand
Heal is looked!
Push the screwdriver
in the hole down to unlock
Heal is unlooked
Lower side
Heater upper side
Lower side
9
Edition: 01/18
Manual
VPS-Design
6. Regulation
From 01.01.2018, the EU conformity of these devices is additionally linked to the fulfillment of the Ecodesign requirements 2015/1188. The installation and commissioning of the devices is only permitted in conjunction with external room temperature controllers that fulfill the following functions:
electronic room temperature control plus week timer
and has at least one of the following properties:
room temperature control, with presence detection
room temperature control, with open window detection
with distance control option
with adaptive start control
with working time limitation
with black bulb sensor
The following room temperature controller systems
RF Receiver together with the TPF-Eco Thermostat (Art.Nr.: 750 000 641) and the Eco­Interface (Art.Nr.750 000 640)
from Technotherm meet the following requirements and therefore the ErP Directive:
electronic room temperature control plus week timer
Installation of the receiver and the interfaces see separate instructions. For customer service - see last page.
Failure to comply with these requirements will result in the loss of the CE mark.
10
Edition: 01/18
Manual
VPS-Design
Lucht LHZ Elektroheizung GmbH & Co. KG Reinhard-Schmidt-Str. 1 D 09217 Burgstädt Fon: +49 (0) 3724 66869 0 Fax: +49 (0) 3724 66869 20 E-mail: info@technotherm.de we b: www.technotherm.de
Model: VPS-Design RF (additional TPF Thermostat and Eco-Interface necessary)
Item
Symbol
Value Value
Item
Value
Heat output
Type of heat input, for electric storage local space heaters only (select one)
Nominal heat output
P
nom
1000 1200 1500 2000 Watt
manual heat charge control, with integrated thermostat
No
Minimum heat
output
(indicative)
P
min
1000 1200 1500 2000 Watt
manual heat charge control with room and/or outdoor temperature feedback
No
Maximum
continuous heat
output
P
max,c
1000 1200 1500 2000 Watt
electronic heat charge control with room and/or outdoor
temperature feedback
No
Auxiliary
electricity
consumption
fan assisted heat output
No
At nominal heat output
el
max
1000 1200 1500 2000 Watt
Type of heat output/room temperature control (select
one)
At minimum heat output
el
min
<0,5 <0,5 <0,5 <0,5 Watt
single stage heat output and no room temperature control
No
In standby mode
el
SB
<0,5 <0,5 <0,5 <0,5 Watt
Two or more manual stages, no room temperature control
No
with mechanic thermostat room temperature control
No
with electronic room temperature control
No
electronic room temperature control plus day timer
No
electronic room temperature control plus week timer
Yes
Other control options (multiple selections possible)
room temperature control, with presence detection
No
room temperature control, with open window detection
No
with distance control option
Yes
with adaptive start control
No
with working time limitation
No
with black bulb sensor
No