3.1.4 Receiver RF- Technical Specifications
• Power Supply 230 V, 50 Hz +/-10%
• Protection Class II
• Expenditure : 0,5 VA
• Switching capacity max.: 16 A 230 Veff Cos j =1 or max. 300 W with lighting control
• Radio Frequency 868 MHz (NormEN 300 220),
• Radio Range up to 300 m in an open field, indoors up to ca. 30m, depending on the
construction of the building and the electromagnetic interference
• Maximal Number of receivers: 8
• Mode of operation: type 1.C (Micro-disconnection)
• Operating Temperature: -5°C to +50°C
• Storage Temperature: -10 °C +70°C
• Dimensions: 120 x 54 x 25 mm
• Degree of Protection : IP 44 - IK 04
• To be installed in average polluted Areas
WARNING
Do not install this device in areas that present an explosion hazard like a garage. Remove
all protective coverage before turning on the device. When using the device for the first time
you might detect a strong odor. This is no reason for concern; it is caused by residues of
production and will disappear shortly.
The rising heat may cause stains on the ceiling, however this phenomena can be caused by
any other heating device as well. Only a qualified electrician may open or remove the device from the power
supply.
4. Maintenance
Before cleaning the device be sure to turn it off. To clean use a damp towel and a mild detergent.
5. Assembly instruction
This Manual is very important and has to be kept at a safe place at all times. Be sure to hand this manual
to any other succeeding owner of the device.
The device is an electrical heater that was designed and intended to be mounted to walls. The device
comes with a power plug that has to be plugged into an outlet.
The device is designed to be connected to 230V (nominal) alternating current (AC).