Technotherm TT-KS S, TT-KS N, TT-KS H Installation And Technical Manual

TT-KS S
TT-KS N TT-KS H
Installation and technical manual
GB
2
3
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE.
BE SURE TO OBSERVE ALL LABELS AND WARNINGS ON THE APPLIANCE.
Edition:07/15
Id_Nr. 911 360 950
2
Manual TT-KS
GB
1. Safety Information
Electrical Connections:
The wires in the mains leads are colored in accordance with the following code: GREEN & YELLOW: EARTH BLUE: NEUTRAL BROWN: LIVE WARNING – THIS APPLIANCE MUST BE EARTHED
The installation of this appliance should be carried out by a competent electrician in accordanc e wi th I.E.E. Regulations for Electrical Equipment.
The radiator is fitted with a standard UK 3 pin plug or EURO plug that can be directly connected to an e lectr ical sock et. Care must be taken when connecting radiators in this way not to overload the ring main circuit. If you are unsure contact a qualified electrician.
Alternatively the mains cable can be cut to length and connected to a suitable fused 20 amp double-pole switched spur adjacent to the radiator. Please ensure that the electricity supply is disconnected prior to using this installation method.
Each supply circuit to the radiator must incorporate a Fused 20 Amp double pole switched spur having a contact separation of at least 3mm.
1.2 Handling
This radiator is very heavy. Take adequate precautions when lifting and maneuvering it. Always assess the load, and seek assistance with heavy or awkward loads that are beyond your capabilities.
1.3 Positioning
This radiator is very heavy. Please refer to Technical Data information contained within this document. In order to maintain stability and to ensure its future safety in use, it is essential that the radiator is FIXED SOUNDLY TO A WALL and that the brackets are mounted on a FIRM, LEVEL SURFACE. Castors or Feet can be purchased as an accessory. Care should be taken to avoid irregular surfaces.
It is important that the following instructions are strictly followed. Keep the following minimum safety distances to avoid fire risk due to high surface
temperatures of the appliance during heating cycles:
Lateral heating walls – masonry ................................................. 50 mm
Lateral heating walls – combustible ma t ter ................................ 100 mm
Heating walls above floo r ............................................................ 80 mm
Cover plate – combustible covering installed on top of it .......... 150 mm
Cover plate – non-combustible covering installed on top of it .. 100 mm
3
Manual TT-KS
GB
Please note that our IPX4 rated models should be used in bathrooms.
Portable radiators must not be fitted in bathrooms or wet areas.
CAUTION – This radiator must not be located below or in front of a fixed socket outlet.
DO NOT POSITION under windows where curtains may contact the radiator.
DO NOT PLACE THE APPLIANCE in the vicinity of a swimming pool.
It is important that the fixing device chosen is appropriate t o the wall material to which the radiator is being fixed. Some modern internal building materials are very low density block
and require specialized fixing devices to provide a safe, secure installation.
CAUTION – If during any reassembly of the radiator, a part of the thermal insulation
shows damage or det erior ation which may im pair safety; it should be replaced wit h an identical part.
CAUTION – In order to avoid overheating, do not cover the radiator.
DO NOT COVER OR OBSTRUCT the surfaces of the appliance.
DO NOT PLACE OBJECTS in contact with the radiator
2.0 General Information
TECHNOTHERM Combination Electric radiators have been designed using the latest technology to create an elegant solution for all hard to heat situations. They can be installed in almost any location apart from the safety restrictions noted in this manual.
The range has been developed to provide a flexible solution for electric heating in Domestic properties, Conservatories, Holiday homes, Offices and any other temporary heating situation.
Our unique patented ’Magmatic’ heating tablets provide the heat source for your new radiator. Whilst the radiator is classed as a 100% efficient Direct Acting appliance, the heating tablets provide partial storage to prolong your heating comfort and to reduce running costs. The radiator has a robust body which incorporates a spot welded high fin surface area to ensure that there are no contraction noises during the heating cycle. The high fin design boasts 6 times the normal radiator surface area to provide a balance of Convection and Radiant heat for your added comfort.
The radiators can be simply plugged in to a “standard” socket or “hard” wired to an existing spur connection. The range has the flexibility of being W all mounted or free standing on Castors or Feet.
For added versatility we can supply Conservatory radiators w hi c h a re also ideal for use below windows with low sills.
All our standard model sizes are supplied with a E4 manual room thermostat. In addition to the above we also supply Radio Frequency controlled radiators which provide all the benefits of the standard version however the control wiring is eliminated. These models can be controlled by our digital transmitter TBF or TPF.
All TECHNOTHERM radiators are manufactured to the highest safety and quality Standards. Each radiator is CE Marked and carries all the necessary European Approvals.
Each radiator is fully checked and tested prior to leaving the factory and as such is packed with full Quality certification.
4
Manual TT-KS
GB
We hope you enjoy the comfort provided by this superior product and we look forward to being of assistance to you in the future.
3.0 Preparation
1. Before beginning, remove the radiator and parts from the box and check everything is
present and correct. In addition to the radiator body, there should be a top grille, a pair of mounting brackets, four suspension hooks, a set of mounting screws/ plugs and an instruction manual.
2. Mark the bracket positions on the wall according to the following diagrams
Model
Power
[Watt]
Dimensions
[cm]
Distance of drill holes
[cm]
Protection
class
TT-KS 500 S
500
38 x 63 x 7
20
IP 20
TT-KS 1000 S
1000
68 x 63 x 7
50
IP 20
TT-KS 1200 S
1200
68 x 63 x 7
50
IP 20
TT-KS 1500 S
1500
98 x 63 x 7
80
IP 20
TT-KS 1800 S
1800
98 x 63 x 7
80
IP 20
TT-KS 2000 S
2000
128 x 63 x 7
110
IP 20
TT-KS 2400 S
2400
128 x 63 x 7
110
IP 20
TT-KS 2800 S
2800
158 x 63 x 7
140
IP 20
TT-KS 500 S X4
500
38 x 63 x 7
20
IP 24
TT-KS 1000 S X4
1000
68 x 63 x 7
50
IP 24
TT-KS 1200 S X4
1200
68 x 63 x 7
50
IP 24
TT-KS 1500 S X4
1500
98 x 63 x 7
80
IP 24
TT-KS 800 N
800
68 x 34 x 7
50
IP 20
TT-KS 1200 N
1200
98 x 34 x 7
80
IP 20
TT-KS 1600 N
1600
128 x 34 x 7
110
IP 20
TT-KS 2000 N
2000
158 x 34 x 7
140
IP 20
TT-KS 800 N X4
800
68 x 34 x 7
50
IP 24
TT-KS 1200 N X4
1200
98 x 34 x 7
80
IP 24
TT-KS 1200 H
1200
38 x 124 x 7
20
IP 20
TT-KS 1800 H
1800
55 x 124 x 7
37
IP 20
TT-KS 2200 H
2200
68 x 124 x 7
50
IP 20
TT-KS 1200 H X4
1200
38 x 124 x 7
20
IP 24
HR 1200 KSB
1200
38 x 124 x 7
20
IP 24
HR 1200 deluxe 1200
52 (64) x 102 x 8,5 (14)*
43,5 IP 24
Loading...