Electrical Connections:
The wires in the mains leads are colored in accordance with the following code:
GREEN & YELLOW: EARTH
BLUE: NEUTRAL
BROWN: LIVE
WARNING – THIS APPLIANCE MUST BE EARTHED
The installation of this appliance should be carried out by a competent electrician in
accordance with I.E.E. Regulations for Electrical Equipment.
The radiator is fitted with a standard UK 3 pin plug or EURO plug that can be directly connected
to an electrical socket. Care must be taken when connecting radiators in this way not to
overload the ring main circuit. If you are unsure contact a qualified electrician.
Alternatively the mains cable can be cut to length and connected to a suitable fused 20 amp
double-pole switched spur adjacent to the radiator. Please ensure that the electricity supply is
disconnected prior to using this installation method.
Each supply circuit to the radiator must incorporate a Fused 20 Amp double pole switched
spur having a contact separation of at least 3mm.
1.2 Handling
This radiator is very heavy. Take adequate precautions when lifting and maneuvering it. Always
assess the load, and
seek a
ssistance with heavy or awkward loads that are beyond your
capabilities.
1.3 Positioning
This radiator is very heavy. Please refer to Technical Data information contained within this
document. In order to fulfil the ErP-Guideline, you need to use castors. Wall mounting is not
allowed.
It is important that the following instructions are strictly followed.
Keep the following minimum safety distances to avoid fire risk due to high surface
temperatures of the appliance during heating cycles:
Lateral heating walls – masonry ................................................. 50 mm
Lateral heating walls – combustible matter ................................ 100 mm
Cover plate – combustible covering installed on top of it .......... 150 mm
Cover plate – non-combustible covering installed on top of it .. 100 mm
• Please note that our IPX4 rated models should be used in bathrooms.
• Portable radiators must not be fitted in bathrooms or wet areas.
• CAUTION – This radiator must not be located below or in front of a fixed socket outlet.
• DO NOT POSITION under windows where curtains may contact the radiator.
• DO NOT PLACE THE APPLIAN
CE in the vicinity of a swimming pool.