THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE
REFERENCE. BE SURE TO OBSERVE ALL LABELS AND WARNINGS ON THE APPLIANCE
Edition: 01/18
Id Nr. 911 360 860
Installation and technical manual
Panel Heater CPH 1000 – 2400 E - Stands
Eco-Design Directive 2015/1188:
This product is only suitable for well-
insulated rooms or for occasional use.
CPH 1500 E
CPH 2000 E
CPH 2400 E

GB
1. For your safety
• This appliance is intended for normal household
use and not for use for vehicles or on board
ships or aircrafts.
• This appliance can be used by children aged
from 8 years and above and persons with
reduced physical, sensory or mental capabilities
or lack of experience and knowledge if they
have been given supervision or instruction
concerning use of the appliance in a safe way
and understand the hazards involved. Children
shall not play with the appliance. Cleaning and
user maintenance shall not be made by children
without supervision.
• Children of less than 3 years should be kept
away unless continuously supervised.
• Children aged from 3 years and less than 8
years shall only switch on/off the appliance
provided that it has been placed or installed in
its intended normal operating position and they
have been given supervision or instruction
concerning use of the appliance in a safe way
and understand the hazards involved. Children
aged from 3 years and less than 8 years shall
not plug in, regulate and clean the appliance or
perform user maintenance.
GB

GB
• CAUTION — Some parts of this product can
become very hot and cause burns. Particular
attention has to be given where children and
vulnerable people are present.
• Make sure that your supply rating corresponds
to what specified on the rating plate: 230V~,
50Hz.
• During function, place the heater in a safe
position:
- at least 1m far from inflammable objects or
furnitures;
- leaving not less than 1m of free space in
front of the heater;
- not located immediately below a socketoutlet.
• Do not leave animals or children touch or play
with the appliance.
• Do not use the heater in rooms with explosive
gas or while using inflammable solvents or
varnish or glues.
• If the cordset is damaged and you have to
change it, do not do the job yourselves! Take the
product to an after sales authorised repair centre
or to a person with similar skill and knowledge,
in order to avoid any risk of danger.
• The appliance must be positioned so that the
plug is always accessible.
• Do not mount the product on walls.

Warning! This device has to be grounded
This device may only be operated using alternating current and the operating voltage indicated
on the power rating plate.
• Nominal Voltage 230V AC, 50 Hz
• Protection Class I
• Degree of Protection IP 24
• Room Thermostat 4°C till 40°C
This devise is only for use with stands – NO wall mounting allowed!
2.1 Technical data
Dimensions (ill.)
a [mm] b [mm] weight [kg]
2. 2 Operation
Connect the heating convector to the mains supply
to set it into operation.
Switching the appliance on
Switch on the appliance by setting the tumbler switch
to position „1“.
Switching the heating on
Switch on the heating by turning the temperature selector switch and choose the required temperature.
The temperature range extends from 4°C to 40°C graduated into 10 steps. The thermostat switches off the
heating as soon as the preset ambient temperature is reached, which will then be kept constant by cyclic
heating. The high consistency of the thermostat (below 2 K) provides a constantly comfortable temperature
and thus ensures power-saving heating.
Anti-freezing protection
When setting the temperature selector switch to grade „1“ the thermostat automatically cuts in if the ambient
temperature falls below 4°C.
GB

Switching the appliance off
Switch off the appliance by setting the tumbler switch to position „0“.
3. Important notes
During operation the temperature at the front panel and at the hot-air outlet of the convector may rise above
85 °C. Do not place any objects on or beside the heater. Free air exit must not be hindered by covering the
hot-air outlets with any objects such as curtains, pieces of laundry etc., otherwise risk of overheating.
Combustible objects such as wood, paper, textiles etc. as well as highly flammable substances such as
wax, petrol, aerosols must not be placed near the heater within the hot-air current. Switch the heater off
when carrying out work where highly flammable vapors could emerge, such as laying or sealing parquet or
other kinds of floor covering or when using aerosols, floor wax, petrol etc.
Caution!
The appliance must not be installed in rooms with explosion hazard such as garages etc. Remove
the protection foil from all panels prior to first use. Should the heater give off a bad smell when it is
heated up for the first time this is caused by manufacturing-related residues, which are harmless
to health. This nuisance will disappear within short time. The rising hot air can cause staining on
the wall, a phenomenon seen in all other types of heaters too. The appliance may only be opened
by an authorized professional with the power supply disconnected.
4. Maintenance
To clean the appliance, switch it off and rub it with a moist cloth using a mild detergent if necessary.
Finally polish with a dry cloth. Do not use any abrasive or caustic detergents for cleaning.
This Manual is very important and has to be kept at a safe place at all times. Be sure to hand this manual
to any other succeeding owner of the device.
5. Installation instructions
These installation instructions are an integral part of the appliance and must be kept in a safe place by the
user. Pass it on to any subsequent user if the owner of the appliance changes. Thanks to graduated heating
capacities they can be adapted to any room size. The convector comes complete with connecting cable
that must be connected to a wall socket. The appliance has been designed to be connected to 230V
alternating current (AC).
Fixing
Fix the appliance in such way that any potentially combustible objects cannot catch fire. Therefore, the
minimum safety distances mentioned below must be kept.
There shall be a minimum space of 10 cm between the heater and any wooden parts or other objects. Any
window sills, roof slopes, brackets etc. must be located at least 50 cm over the hot-air outlets of the heater.
If the appliance is used in bathrooms, install it in such way that the tumbler switch or the temperature
selector cannot be touched by a person being in the tub or under the shower.
Caution Do not install the appliance below a wall socket. The appliance is not suitable for
outside use.
GB

Electrical installation
The appliance has been designed to be connected to 230V alternating current (AC). All electrical installation
work, in particular protective measures, must be carried out in compliance with the national regulations and
statutory provisions of the respective utilities provider.
The electrical installation may only be carried out in compliance with the installation instructions
by an authorized professional!
Permanent cables must not be connected directly to the appliance! If the electrical installation is done by
means of an isolating unit, it should be taken care that the isolation is designed with at least 3 mm separation
on all poles.
Type of connection of the appliance:
Type Y acc. to VDE 0700 Part 1.
In case the connecting cable is damaged, it may only be replaced by a repair shop appointed by
the manufacturer!
The minimum distance between appliance and connector socket must be 10 cm. The connecting cable
must not have contact with the appliance.
Diagram of connections
GB

6. Directive
From 01.01.2018, the EU conformity of these devices is additionally linked to the fulfillment of the
Ecodesign requirements 2015/1188.
The installation and commissioning of the devices is only permitted in connection with feet. Wall
mounting is not permitted.
Failure to comply with these requirements will result in the loss of the CE mark.
Lucht LHZ Elektroheizung GmbH & Co. KG
Reinhard-Schmidt-Str. 1
D 09217 Burgstädt
Fon: +49 (0) 3724 66869 0
Fax: +49 (0) 3724 66869 20
E-mail: info@technotherm.com
Web: www.technotherm.com
Model: CPH E (only in combination with feet)
Type of heat input, for electric storage local space heaters only (select one)
P
nom
1000 1500 2000 2400 Watt
manual heat charge control, with integrated thermostat
No
P
min
1000 1500 2000 2400 Watt
manual heat charge control with room and/or outdoor temperature
feedback
No
P
max,c
1000 1500 2000 2400 Watt
electronic heat charge control with room and/or outdoor
temperature feedback
No
fan assisted heat output
No
At nominal heat
output
el
max
1000 1500 2000 2400 Watt
Type of heat output/room temperature control (select
one)
<0,5 <0,5 <0,5 <0,5 Watt
single stage heat output and no room temperature control
No
In standby mode
el
<0,5 <0,5 <0,5 <0,5 Watt
Two or more manual stages, no room temperature control
No
with mechanic thermostat room temperature control
with electronic room temperature control
electronic room temperature control plus day timer
electronic room temperature control plus week timer
Other control options (multiple selections possible)
room temperature control, with presence detection
room temperature control, with open window detection
with distance control option
with adaptive start control
with working time limitation
Lucht LHZ Elektroheizung GmbG & Co. KG | Reinhard-Schmidt.Str.1 D-09217 Burgstädt
Fon: +49 (0) 911 937 83 210