|9
TECHNOTHERM a brand of Lucht LHZ GmbH & Co. KG
Reinhard-Schmidt-Str. 1 | 09217 Burgstädt
Telefon: +49 (0) 3724 66869 0
Telefax: +49 (0) 3724 66869 20
info@technotherm.de | www.technotherm.de
Subject to errors and technical amendments. Dimensions without guarantee! Edion 01/18
TECHNOTHERM Support
+49 (0) 911 937 83 210
Information requirements for electric local space heaters
From 01.01.2018, the EU conformity of these devices is additionally linked to the fulllment of the Ecodesign requirements 2015/1188.
The installation and commissioning of the devices is only permitted in conjunction with external room temperature controllers that fulll the following functions:
• Electronic room temperature control with weekday control
And has at least one of the following properties:
• Room temperature control with presence detection
• Room temperature control with “open window” function
• with remote control option
• with adaptive start control
• with heating time limitation
Technotherm meets the following requirements and thus the ErP Directive:
• Electronic room temperature control with weekday
• distance control option
• adaptive start control
• room temperature control, with open window detection
Failure to comply with these requirements will result in the loss of the CE mark.
The additional operating instructions for setting up the thermostats and interfaces please ask in our support - see last page!
Model: CHM DSM (Operation only permitted in conjunction with the DSM-interface)
Item Symbol Value Value Item Value
Heat output
Type of heat input, for electric storage local space heaters only (select one)
Nominal heat output
P
nom
05 1,0 1,5 2,0 kW
manual heat charge control, with integrated thermostat NO
Minimum heat
output (indicative)
P
min
0,5 1,0 1,5 2,0 kW
manual heat charge control with room and/or outdoor temperature
feedback
NO
Maximum continuous heat output
P
max,c
0,5 1,0 1,5 12,0 kW
electronic heat charge control with room and/or outdoor
temperature feedback
NO
Auxiliary electricity consumption
fan assisted heat output NO
At nominal heat
output
el
max
0,5 1,0 1,5 2,0 W
Type of heat output/room temperature control (select
one)
At minimum heat
output
el
min
<0,5 <0,5 <0,5 <0,5
W
single stage heat output and no room temperature control No
Two or more manual stages, no room temperature control No
In standby mode
el
SB
<0,5 <0,5 <0,5 <0,5
W
with mechanic thermostat room temperature control N0
with electronic room temperature control No
electronic room temperature control plus day timer
No
electronic room temperature control plus week timer
Yes
Other control options (multiple selections possible)
room temperature control, with presence detection No
room temperature control, with open window detection Yes
with distance control option Yes
with adaptive start control Yes
with working time limitation No
with black bulb sensor
No
Contact Information:
Lucht LHZ Elektroheizung GmbG & Co. KG | Reinhard-Schmidt.Str.1 D-09217 Burgstädt