Features :
The electronic lock has the possibility to program two different codes (main code and second user
code).
By new safes the default main code is : 123456 and the second user code is not programmed.
Time delay is disabled.
Main and second user code must be of 6 digit.
External power supply through contacts on keypad.
Possibility to program a time-delay opening from 0 to 99 minutes.
Open:
Ø Enter a six digits valid main code ( factory default main code 1-2-3-4-5-6 ).
* A valid code is followed by a double signal.
* An invalid code is followed by a long signal.
Ø If time delay is not active open the door. Ø If time delay is active the counting starts (during time delay counting the light flashes every 2 seconds). Ø When time delay elapses, open window counting starts (during open window counting the buzzer beeps
every 2 seconds).
Ø Enter the main code again and open the door.
Note:
If the door is not opened within 3 (three) seconds, the lock secures automatically.
Manipulation protection:
The entry of 4 (four) consecutives invalid codes, will cause a 5 (five) minutes lock blocking. During this period, the light flashes every 10 seconds and any key pressed will produce a long signal. After expiration, the entry of 2 (two) more invalid codes, will restart the 5 minutes blocking period.
Battery contacts
Fig. 1
TECHNOMAX SRL
VIA CASA BIANCA, 10 26037 SAN GIOVANNI IN CROCE (CR)
TEL +39 0375 310 281 - FAX +39 0375 310282 www.technomax.it
Istr-Euroline-r03-eng.doc pagina 2 di 4
Change main code:
Ø Press and hold key “0” until double signal. Ø Enter the main code in use (double signal).
Factory default is 123456
Ø Enter the new main code (double signal). Ø Repeat the new main code (double signal).
Note:
In case of errors ( long signal ) the main code in use remains valid.
Always perform this operation with the door opened. Test lock operation several times before closing the door.
WARNING:
forget the main code involves the forced opening of the safe with inevitable damage.
Add the second user code:
Ø Press and hold key “1” until double signal;
the light remains switched on during the following actions.
Ø Enter the main code. Ø Enter the new second user code (double signal). Ø Confirm the new second user code (double signal).
.
Delete the second user code:
Ø Press and hold key “3” until double signal;
the light remains switched on during the following actions.
Ø Enter the main code. Ø The second user code is now deleted.
Membrane check-up:
Ø Press and hold key “5” until double signal. Ø Enter the following sequence of numbers:
1-2-3-4-5-6-7-8-9-0. * Double signal = key correctly working.
* Long signal = key not working.