The Technologic Systems TS-ENC530 is a metal enclosure designed to house the TS-3300 or
TS-5300 single-board computers and two PC/104 peripheral boards. This manual is intended
to provide the user with an overview of the enclosure’s features, benefits, specifications, and
set up procedures. It also contains important safety information.
Features and Benefits
The switching power regulator efficiently converts 12-38 VDC to regulated +5 VDC
required by the SBC
COM ports adapted to standard 9-pin Sub-D
Status LED's for Ethernet port are visible
Power Good LED visible on the rear panel
Surge suppression on DC power input
Sturdy metallic design reduces noise
Dimensions of the enclosure are 2-3/8" x 5" x 6"
Related Products
The TS-ENC530 enclosure is designed for the following single-board computers:
TS-3300
TS-5300
Software and Support
Free system software and documentation updates available on our web site
Free technical support by phone, fax, or email
30-day, money back guarantee on evaluation units
One-year, full warranty
TS-ENC530 - 4
Page 5
Installing the Enclosure
Electrostatic Discharge (ESD) precautions
Before performing any set up or placement procedures, take the precautions outlined in this
section.
Important
i
Be sure to take appropriate Electrostatic Discharge (ESD) precautions.
Disconnect the power cable at the rear panel of the enclosure before moving,
cabling, or performing any set up procedures.
Setup and Installation Instructions
Follow these guidelines for safety and maximum product performance:
Observe local health and safety requirements and guidelines for manual material handling.
Set the enclosure on a level surface with adequate ventilation.
TS Enclosure 530 User Manual
Ensure the rubber feet are used for protection and stability on level surfaces.
Wall-mount the unit if placement on a level surface is not available, or desired.
Setup Tools
Depending on the placement and cabling of the enclosure, you may need the following tools:
Small flat-blade screwdriver
Small Phillips screwdriver
Setup Procedure
After locating, setting up, grounding, and cabling the enclosure:
1. Apply power to the unit.
The amber-colored LED on the rear panel should be lit.
2. Monitor COM2 using a terminal emulator to verify that the enclosure is operating
properly.
Disconnecting AC Power
1. Unplug the power cord from the power source.
2. Disconnect the power cord from the rear panel of the enclosure.
Rev. 1.2TS-ENC530 - 5
Page 6
Technologic Systems, Inc.
223344556
Components
Standard Headers and Connectors
Front Panel
See Appendix A for a view of the enclosure’s front panel.
Rear Panel
6
1
1
TS Enclosure 530 Rear Panel Connectors
The rear panel of the metal enclosure has four connectors and two additional elements, as
indicated in the above view. Identifiers, and a description for each, are listed in the tables
below.
Identifier Connector Description
11
22
33
44
Ethernet
COM1
COM2
12-38VDC
Additional Elements
Identifier Description
55
66
Power Indicator LED
Chassis Grounding Lug
TS-ENC530 - 6
Page 7
TS Enclosure 530 User Manual
Enclosure TS-530 Ethernet Port
Ethernet: The Ethernet connector is a standard RJ-45 socket. It can be used to connect a
standard 10baseT Ethernet cable into the enclosed EPC.
Enclosure TS-530 COM1 Port
COM1: COM1 is brought in from the enclosed SBC. This 9-pin SubD connector is
industry standard for a PC. The TxD, RxD, RTS, CTS, and ground pins are supported for
RS-232 communications.
See the table below for RS-485 operation.
COM1 9-Pin SubD Outs Table
Half Duplex RS-485RS-232Full Duplex RS-485
9-Pin
SubD
11
22
33
44
55
66
77
88
99
Signal
RX/TX +
Ground
RX/TX -
9-Pin
SubD
11
22
33
44
55
66
77
88
99
Signal
Receive data
Transmit data
Ground
Request to Send
Clear to Send
9-Pin
SubD
11
22
33
44
55
66
77
88
99
Signal
TX +
RX +
Ground
TX -
RX -
Rev. 1.2TS-ENC530 - 7
Page 8
Technologic Systems, Inc.
COM 2: COM2 is brought in from the base SBC. This 9-pin SubD connector is industry
standard for a PC. The TxD, RxD, RTS, CTS, and ground pins are supported for RS-232
communications.
COM2 9-Pin SubD Outs Table
Enclosure TS-530 COM2 Port, Pin 1
RS-232
9-Pin
SubD
11
22
33
44
55
66
77
88
99
Signal
Receive data
Transmit data
Ground
Request to Send
Clear to Send
12-38VDC: The three-pin connector accepts 12-38 VDC of external power to supply
Power Indicator Light: The amber-colored LED indicator on the rear panel, shown
TS-ENC530 - 8
Enclosure TS-530 12-38 VDC Connector
power to the board.
Power Indicator Light
highlighted above in red, is the power LED. It is lit whenever power is applied to the unit.
Chassis Grounding Lug
Page 9
TS Enclosure 530 User Manual
Chassis Grounding Lug: The lug labeled with the chassis ground symbol is used to
ground the chassis (optional).
Note
Connec
t this to earth ground during installation.
Rev. 1.2TS-ENC530 - 9
Page 10
Technologic Systems, Inc.
Product Specifications
Dimensions
The TS Enclosure 530 measures 2-3/8" x 5" x 6"
Cabling
A mating power connector is supplied with the enclosure
A null modem cable is available as CB7-05
Environmental
To ensure optimum product operation you must maintain the operational environmental
specifications listed in the table below.
Environmental
Specifications
Ambient Temperature
Relative Humidity
Standard Temp
Products
0 - 60° C
The internal temperature
must not exce
Not to exceed 90%
noncondensing
ed +70° C.
Extended Temp Products
Allow for a much greater range.
Note: Refer to your pro
or contact Customer Service at
Technologic Systems if the
environmental temperature of the
location is in doubt.
Not to exceed 90% noncondensing.
duct manual,
TS-ENC530 - 10
Page 11
Options and Other Features
RS-485 is optional on COM1
A wall-mounted power supply is available for this product
TS Enclosure 530 User Manual
Rev. 1.2TS-ENC530 - 11
Page 12
Technologic Systems, Inc.
Limited Warranty
Technologic Systems warrants this product to be free of defects in material and workmanship
for a period of one year from date of purchase.
Repairs
During this warranty period Technologic Systems will repair or replace the defective unit in
accordance with the following process:
A copy of the original invoice must be included when returning the defective unit to
Technologic Systems, Inc. at the address below.
Not Covered
This limited warranty does not cover damages resulting from lighting or other power surges,
misuse, abuse, abnormal conditions of operation, or attempts to alter or modify the function of
the product.
Important
i
This warranty is limited to the repair or replacement of the defective unit. In no
event shall Technologic Sy
damages, including but not limited to any lost profits, incidental or
consequential damages, loss of business, or anticipatory profits arising from
the use or inability to use this product.
stems be liable or responsible for any loss or
Out-of-Warranty Repairs
Repairs made after the expiration of the warranty period are subject to a repair charge and the
cost of return shipping.
Please contact Technologic Systems to arrange for any repair service and to obtain repair
charge cost information.
16525 East Laser Drive
Fountain Hills, AZ 85268
TEL 480.837.5200
FAX 480.837.5300
http://www.embeddedx86.com/
TS-ENC530 - 12
Page 13
Regulatory Notices
FCC Advisory Statement
! Warning
This equipment generates, uses, and can radiate radio frequency energy and if not installed and
used properly (that is, in strict accordance with the manufacturer’s instructions), may cause
interference to radio and television reception. It has been type tested and found to comply with
the limits for a Class A computing device in accordance with the specifications in Subpart J of
Part 15 of FCC Rules, which are designed to provide reasonable protection against such
interference when operated in a commercial environment. Operation of this equipment in a
residential area is likely to cause interference, in which case the owner at his own expense will
be required to correct the interference.
If this equipment does cause interference, which can be determined by turning the unit on and
off, the user is encouraged to try the following measures to correct the interference:
TS Enclosure 530 User Manual
1. Reorient the receiving antenna.
2. Relocate the unit with respect to the receiver.
3. Plug the unit into a different outlet so that the unit and receiver are on different branch
circuits.
4. Ensure that mounting screws and connector attachment screws are tightly secured.
5. Ensure that good quality, shielded, and grounded cables are used for all data
communications.
If necessary, the user should consult the dealer or an experienced radio/television technician
for additional suggestions. The following booklets prepared by the Federal Communications
Commission (FCC) may also prove helpful:
How to Identify and Resolve Radio-TV Interference Problems (Stock No. 004-000-
000345-4)
Interface Handbook (Stock No. 004-000-004505-7)
These booklets may be purchased from the Superintendent of Documents, U.S. Government
Printing Office, Washington, DC 20402
Rev. 1.2TS-ENC530 - 13
Page 14
Technologic Systems, Inc.
Appendix A: Enclosure Views
Enclosure TS-530 Front-Top View
Enclosure TS-530 Rear Panel View
TS-ENC530 - 14
Page 15
Appendix B: User Manual Revisions
Date of Issue/RevisionRevision NumberComments
July 2004
July 2008
June 2009 1.2 Updated mailing address
1.0
1.1
First release
Fixed broken web links
TS Enclosure 530 User Manual
Rev. 1.2TS-ENC530 - 15
Page 16
Technologic Systems, Inc.