WEATHER STATION
INTRODUCTION
Congratulations on purchasing this weather station as an example of innovative design and
quality piece of engineering. Providing time, date, calendar, indoor and outdoor temperature,
indoor and outdoor relative humidity, and air pressure history information, this unit will never
keep you guessing on current and future weather conditions. Operation of this product is
simple and straightforward. By reading this operating manual, the user will receive a better
understanding of the weather station together with the optimum benefit of all its features.
FEATURES
The Weather Station
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Thermo-Hygro Transmitter
SETTING UP
Note: This weather station receives only one outdoor transmitter.
1. First, insert the batteries in the transmitter (see “How to install and replace batteries
2. Within 30 seconds of powering up the transmitter, insert batteries in the weather station
3. After the batteries are inserted, the weather station will start receiving data signal from
4. In order to ensure successful 868 MHz transmission, the distance between the weather
5. Once the outdoor data reception test period is completed, the DCF tower icon in the
TO INSTALL AND REPLACE BATTERIES IN THE WEATHER STATION
TO INSTALL AND REPLACE BATTERIES IN THE THERMO-HYGRO
TRANSMITTER
Hanging hole
keys
DCF Radio controlled time with manual setting option
Time reception ON/OFF setting
Weekday, date and month display (year only in setting mode)
Time zone option (-2h to +5h)
Daylight saving time (DST) setting
Alarm setting
Temperature display in degree Celsius (°C)
Indoor temperature display with MIN/MAX recordings
Outdoor temperature display with MIN/MAX recordings with time and date received
All MIN/MAX recordings can be reset
Indoor and outdoor humidity display in RH%
Weather forecast with weather tendency indicator
Relative air pressure history for the past 12 hours
LCD contrast setting
Low battery indicator
Table standing or wall mounting
•
Remote transmission of outdoor temperature and humidity to weather
station by 868MHz
•
Wall mounting case
•
Mounting at a sheltered place. Avoid direct rain and sunshine
in the thermo-hygro transmitter” above).
(see “How to install and replace batteries in the weather station” above). Once the
batteries are in place, all segments of the LCD will light up briefly and a short signal
tone will sound. Then the indoor temperature, humidity and the time as 0:00 will be
displayed. If these information are not displayed on the LCD after 60 seconds, remove
the batteries and wait for at least 60 seconds before reinserting them. Once the indoor
data is displayed user may proceed to the next step.
the transmitter. The outdoor temperature and humidity data should then be displayed
on the weather station. If this does not happen after 2 minutes, the batteries will need
to be removed from both units and reset from step 1.
station and the transmitter should be within 100 meters (see notes on “Positioning”
and “868 MHz Reception”).
clock display will start flashing in the upper left corner. This indicates that the clock has
detected that there is a radio signal present and is trying to receive it. When the time
code is received, the DCF tower becomes permanently lit and the time will be
displayed.
The outdoor thermo-hygro transmitter uses 2 x AAA, IEC LR3, 1.5V batteries. To
install and replace the batteries, please follow the steps below:
1. Remove the battery cover by pushing the battery cover upwards with your
thumb.
2. Insert the batteries, observing the correct polarity (see battery
compartment marking).
Instruction Manual
The weather station uses 3 x AAA, IEC LR3,
1.5V batteries. To install and replace the
batteries, please follow the steps below:
1. Insert finger or other solid object in the
2. Insert batteries observing the correct
3. Replace compartment cover.
LCD
Display
keys
Battery
compartment
Stand
space at the bottom center of the
battery compartment and lift up to
remove the cover.
polarity (see marking).
3.
Replace the battery cover on the unit.
Note:
In the event of changing batteries in any of the units, all units need to be reset by following
the setting up procedures. This is due to a random security code assigned by the transmitter
at start-up. This code must be received and stored by the weather station in the first 3
minutes of power being supplied to the transmitter.
DCF RADIO CONTROLLED TIME
The time base for the radio controlled time is a Cesium Atomic Clock operated by the
Physikalisch Technische Bundesanstalt Braunschweig which has a time deviation of less than
one second in one million years. The time is coded and transmitted from Mainflingen near
Frankfurt via frequency signal DCF-77 (77.5 kHz) and has a transmitting range of
approximately 1,500 km. Your radio-controlled weather station receives this signal and
converts it to show the precise time in summer or wintertime.
The quality of the reception depends greatly on the geographic location. In normal cases,
there should be no reception problems within a 1,500 km radius of Frankfurt.
DCF reception is done twice daily at 02:00 and 03:00 am. If the reception is not successful at
03:00 am, then the next reception takes place the next hour and so on until 06:00am, or until
the reception is successful. If the reception is not successful at 06:00 am, then the next
attempt will take place the next day at 02:00 am.
If the tower icon flashes, but does not set the time or the DCF tower does not appear at all,
then please take note of the following:
•
•
•
FUNCTION KEYS:
Weather station:
The weather station has 4 easy to use function keys:
SET key
•
•
+ key
•
•
•
MIN/MAX key
•
•
•
•
ALARM key
•
•
•
•
LCD SCREEN
The LCD screen is split into 3 sections displaying the information for time/calendar, indoor
data, weather forecast and air pressure history, and outdoor data.
Recommended distance to any interfering sources like computer monitors or TV sets is
a minimum of 1.5 - 2 meters.
Within ferro-concrete rooms (basements, superstructures), the received signal is
naturally weakened. In extreme cases, please place the unit close to a window and/ or
point its front or back towards the Frankfurt transmitter.
During nighttime, the atmospheric disturbances are usually less severe and reception is
possible in most cases. A single daily reception is adequate to keep the accuracy
deviation below 1 second.
+ key
MIN/MAX
Press and hold for 2 seconds to enter manual setting modes: LCD contrast, time zone,
time reception ON/OFF, DST ON/OFF, manual time setting and calendar
To stop the alarm sound
To increase/change values in setting modes
Toggle between time / date / humidity / seconds display
To stop the alarm sound
To toggle between the indoor and outdoor MIN/MAX temperature
To decrease/change values in setting modes
Press and hold for 3 seconds to reset ALL indoor/outdoor minimum/maximum
temperature recordings to current readings
To stop the alarm sound
To activate/deactivate the alarm and display alarm time
Press and hold for 2 seconds to enter the alarm setting mode
To stop the alarm sound
To exit the manual setting mode
Weekday
Time Alarm icon
SET key
ALARM key
Indoor humidity
display in RH%
forecast icon
* When the signal is successfully received by the weather station, the outdoor transmission
icon will be switched on. (If not successful, the icon will not be shown on LCD). The user can
then easily see whether the last reception was successful (icon on) or not (icon off).
MANUAL SETTINGS
The following settings can be changed when pressing and holding the SET key:
•
LCD contrast setting
•
Time zone setting
•
Time reception ON/OFF setting
•
Daylight saving time (DST) ON/OFF setting
•
Manual time setting
•
Calendar setting
LCD CONTRAST SETTING
(weather station)
MIN/MAX outdoor
temperature display
Low battery indicator
(outdoor transmitter)
Air pressure history
bar graph
Outdoor data signal
reception indicator *
Outdoor humidity
display in RH%
Flashing
The LCD contrast can be set within 8 levels, from LCD 0 to LCD 7 (Default is LCD 4):
1. The LCD contrast level starts flashing.
2. Use the + or MIN/MAX key to select the level of contrast desired.
3. Confirm with the SET key and enter the Time Zone Setting.
TIME ZONE SETTING:
The time zone default of the weather station is “0”. To set a different time zone:
1. The current time zone value starts flashing.
2. Use the + or MIN/MAX key to set the time zone. The range runs from -2h to +5h hours
in 1-hour intervals.
3. Confirm with the SET key and enter the Time Reception ON/OFF Setting.
TIME RECEPTION ON/OFF SETTING
In area where reception of the DCF-77 time signal is not possible, the DCF-77 time reception
function can be turned OFF. The clock will then work as a normal quartz clock. (Default
setting is “1” = ON).
1. The digit “1” will start flashing on the LCD.
2. Use the + or MIN/MAX key to turn OFF (“0” = OFF) the time reception function.
3. Confirm with the SET key and enter the Daylight Saving Time (DST) ON/OFF
Setting.
Note:
•
If the Time Reception function is turned OFF manually, the clock will not attempt any
reception of the DCF time as long as the Time Reception OFF function is activated.
•
The time reception “ “ and the “DCF” icons will not be displayed on the LCD.
DAYLIGHT SAVING TIME (DST) ON/OFF SETTING
The daylight saving time (DST) function can be set ON/OFF. Default setting is “1” = ON:
1. The digit “1” will start flashing on the LCD.
2. Use the + or MIN/MAX key to turn OFF (“0” = OFF) the daylight saving function.
3. Confirm with the SET key and enter the Manual Time setting.
Important:
This function is only significant if the time reception setting is turned OFF “0”.
•
Daylight saving time setting “1” (ON): the clock calculates DST automatically in
normal quartz mode. DST begins on the last Sunday of March and ends on the last
Sunday of October.
•
Daylight saving time setting “0” (OFF): DST feature is OFF and the clock will not
change time automatically.
If the time reception setting is turned ON “1”, please set the daylight saving time “1”
(ON): the time change will be updated by the DCF-77 signal (as long as a proper reception is
possible).
In case of daylight saving time setting “0” (OFF): the time will be transmitted by the DCF-77
signal, but the clock calculates automatically a “no-DST time”.
MANUAL TIME SETTING:
In case the weather station cannot detect the DCF-signal (for example due to disturbances,
transmitting distance, etc.), the time can be manually set. The clock will then work as a
normal quartz clock.
1. The hour digit will start flashing.
2. Use the + or MIN/MAX key to set the hour. Keep holding the key allows the digit to
advance faster.
3. Press again the SET key to set the minutes. The minute digits start flashing.
4. Use the + or MIN/MAX key to set the minutes. Keep holding the key allows the digit to
advance faster
5. Confirm with the SET key and enter the Calendar setting.
Note:
•
The unit will still try and receive the signal despite it being manually set. When it does
receive the signal, it will change the manually set time into the received time. During
reception attempts the DCF tower icon will flash. If reception has been unsuccessful,
then the DCF tower icon will not appear but reception will still be attempted the
following day.
•
The time reception “ “ and the “DCF” icons will not be displayed on the LCD after
manual time setting.
CALENDAR SETTING
Hour flashing Minutes flashing
Flashing
Flashing
Flashing
Weekday
1.
The year digits will start flashing. The range runs from 2011 to 2025 (default is 2011).
2.
Use the + or MIN/MAX key to set the year. Keep holding the key allows the value to
advance faster.
3.
Press the SET key to confirm and enter the month setting mode.
4.
The month digit will be flashing. Use the + or MIN/MAX key to set the month. Keep
holding the key allows the value to advance faster.
5.
Press the SET key to enter date setting.
6.
The date digit will be flashing. Use the + or MIN/MAX key to set the date. Keep holding
the key allows the value to advance faster.
7.
Confirm with the SET key and exit the manual setting.
Note:
The weekday is automatically displayed above the time in short form (from Monday to
Sunday): MO / TU / WE / TH / FR / SA / SU.
Year
Date. Month.
TO EXIT THE MANUAL SETTING MODE
To exit the manual setting mode anytime during the manual setting, press the ALARM key.
The mode will return to normal time display.
ALARM SETTING
To set the alarm:
1. Press and hold ALARM key for 3 seconds until the alarm time shown.
2. The hour digit will be flashing. Use the + or MIN/MAX key to adjust the hour. Keep
holding the key allows the value to advance faster.
3. Use the ALARM key again, and the minute digits will be flashing. Press + or MIN/MAX
key to set the minute. Keep holding the key allows the value to advance faster.
4. Press the ALARM key to confirm the setting.
Note:
To activate/deactivate the alarm function, press the ALARM key once. The display of the
alarm icon represents that the alarm is "ON".
The duration of alarm sounding is 2 minutes. Press any key will stop the alarm sound.
WEATHER FORECASTING ICONS:
The weather icons in the second section of LCD can be displayed in any of the following
combinations:
For every sudden or significant change in the air pressure, the weather icons will update
accordingly to represent the change in weather. If the icons do not change, then it means
either the air pressure has not changed or the change has been too slow for the weather
station to register. However, if the icon displayed is a sun or raining cloud, there will be no
change of icon if the weather gets any better (with sunny icon) or worse (with rainy icon) since
the icons are already at their extremes.
The icons displayed forecasts the weather in terms of getting better or worse and not
necessarily sunny or rainy as each icon indicates. For example, if the current weather is
cloudy and the rainy icon is displayed, it does not mean that the product is faulty because it is
not raining. It simply means that the air pressure has dropped and the weather is expected to
get worse but not necessarily rainy.
Note:
After setting up, readings for weather forecasts should be disregarded for the next 12-24
hours. This will allow sufficient time for the weather station to collect air pressure data at a
constant altitude and therefore result in a more accurate forecast.
Common to weather forecasting, absolute accuracy cannot be guaranteed. The weather
forecasting feature is estimated to have an accuracy level of about 75% due to the varying
areas the weather station has been designed for use. In areas that experience sudden
changes in weather (for example from sunny to rain), the weather station will be more
accurate compared to use in areas where the weather is stagnant most of the time (for
example mostly sunny).
If the weather station is moved to another location significantly higher or lower than its initial
standing point (for example from the ground floor to the upper floors of a house), discard the
weather forecast for the next 12-24 hours. By doing this, the weather station will not mistake
the new location as being a possible change in air-pressure when really it is due to the slight
change of altitude.
WEATHER TENDENCY INDICATOR
The weather tendency indicators (located on the left side of the weather icons) are working
together with the weather icons. When the indicator points upwards, it means that the airpressure is increasing and the weather is expected to improve, but when indicator points
downwards, the air-pressure is dropping and the weather is expected to become worse.
Taking this into account, one can see how the weather has changed and is expected to
change. For example, if the indicator is pointing downwards together with cloud and sun
icons, then the last noticeable change in the weather was when it was sunny (the sun icon
only). Therefore, the next change in the weather will be cloud with rain icons since the
indicator is pointing downwards.
Note:
Once the weather tendency indicator has registered a change in air pressure, it will remain
permanently visualized on the LCD.
AIR PRESSURE HISTORY (ELECTRONIC BAROMETER WITH BAROMETRIC
PRESSURE TREND)
The right side of the second section of the LCD shows the air pressure history bar graph.
The bar graph indicates the air pressure history trend over the last 12 hours in 7 intervals: 0h,
-3h, -6h, -9h and -12h. The “0h” represents the current full hour air pressure recording. The
columns represent the “hPa” (0, ±1, ±3, ±5) at specific time. The “0” in the middle of this scale
is equal to the current pressure and each change (±1, ±3, ±5) represents how high or low in
“hPa“ the past pressure was compared to the current pressure.
If the bars are rising it means that the weather is getting better due to the increase of air
pressure. If the bars go down, it means the air pressure has dropped and the weather is
expected to get worse from the present time “0h“.
Note:
•
•
INDOOR TEMPERATURE/HUMIDITY DATA
The indoor temperature and humidity data are automatically updated and displayed on the
first section of the LCD.
Sunny
For accurate barometric pressure trends, the weather station should operate at the
same altitude for recordings (i.e. it should not be moved from the ground to the second
floor of the house). When the unit is moved to a new location, discard readings for the
next 12 hours.
The level of the pressure bar will be affected by the temperature change and it is for
reference only.
Alarm time (flashing)
Alarm indicator (ON)
Cloudy with sunny intervals
Air pressure trend over the
last 12 hours
Rainy
30
in ºC
OUTDOOR TEMPERATURE/HUMIDITY DATA
The last LCD section shows the outdoor temperature and humidity, and the reception
indicator.
in °
TOGGLING AND RESETTING THE TEMPERATURE MIN/MAX DATA
TO VIEW THE MIN/MAX TEMPERATURE DATA
Press the MIN/MAX key several times to view the MIN/MAX indoor and outdoor temperature
sequentially.
Note: the outdoor MIN/MAX temperature records will also display the recorded time and date.
MAX outdoor
temperature
TO RESET TEMPERATURE MIN/MAX DATA
Press and hold MIN/MAX key for 3 seconds to reset all the indoor and outdoor temperature
to current temperatures.
ABOUT THE THERMO-HYGRO TRANSMITTER
The range of the thermo-hygro transmitter may be affected by the temperature. At cold
temperatures the transmitting distance may be decreased. Please bear this in mind when
positioning the transmitters. Also the batteries may be reduced in power for the thermo-hygro
transmitter.
CHECKING FOR 868MHz RECEPTION
If the outdoor temperature and humidity data are not being received within three minutes after
setting up (or outdoor display always shows “- -.-” in the outdoor section of the weather
station during normal operation), please check the following points:
1. The distance of the weather station or transmitters should be at least 2 meters away
2. Avoid placing the transmitters onto or in the immediate proximity of metal window
3. Using other electrical products such as headphones or speakers operating on the
Note:
When the 868MHz signal is received correctly, do not re-open the battery cover of either the
transmitter or weather station, as the batteries may spring free from the contacts and force a
false reset. Should this happen accidentally then reset all units (see “Setting up” above)
otherwise transmission problems may occur.
The transmission range is around 100 meters from the thermo-hygro transmitter to the
weather station (in open space). However, this depends on the surrounding environment and
interference levels. If no reception is possible despite the observation of these factors, all
system units have to be reset (see “Setting up” above).
POSITIONING THE WEATHER STATION
temperature)
from any interfering sources such as computer monitors or TV sets.
frames.
868MHz-signal frequency may prevent correct signal transmission or reception.
Neighbors using electrical devices operating on the 868MHz-signal frequency can also
cause interference.
The weather station provides the option of table standing or wall mounting
the unit. Before wall mounting, please check that the outdoor data can be
received from the desired locations.
To wall mount:
1. Fix a screw (not supplied) into the desired wall, leaving the head
2. Place the weather station onto the screw, using the hanging hole on
Foldout table stand:
The foldout table stand leg is located on the backside. Pull the stand out
from the bottom center edge of the weather station, below the battery
compartment. Once the foldout table stand is extended, place the
weather station in an appropriate location.
Recorded
time of the
outdoor
MIN/MAX
records
extended out by about 5mm.
the backside. Gently pull the weather station down to lock the screw
into place.
Indoor relative
humidity in
RH%
Outdoor
reception
icon
Outdoor humidity
in RH%
Recorded
date of the
outdoor
MIN/MAX
records
POSITIONING THE THERMO-HYGRO TRANSMITTER
CARE AND MAINTENANCE
•
Mounting at a sheltered place. Avoid direct rain and sunshine.
The thermo-hygro transmitter can be placed onto any flat surface or wall mount
using the bracket which doubles as a stand or wall mount base.
To wall mount:
1. Secure the bracket onto a desired wall using the screws and plastic anchors.
2. Clip the transmitter onto the bracket.
Note:
Before permanently fixing the thermo-hygro to the wall base, pace all units in the
desired locations to check that the outdoor temperature and humidity readings are
receivable. In event that the signal is not received, relocate the thermo-hygro
transmitter or the weather station slightly as this may help the signal reception.
Extreme temperatures, vibration and shock should be avoided as these may cause
damage to the unit and give inaccurate forecasts and readings.
•
When cleaning the display and casings, use a soft damp cloth only. Do not use
solvents or scouring agents as they may mark the LCD and casings.
•
Do not submerge the unit in water.
•
Immediately remove all low powered batteries to avoid leakage and damage. Replace
only with new batteries of the recommended type.
•
Do not make any repair attempts to the unit. Return them to their original point of
purchase for repair by a qualified engineer. Opening and tampering with the unit may
invalidate their guarantee.
•
Do not expose the units to extreme and sudden temperature changes, this may lead to
rapid changes in forecasts and readings and thereby reduce their accuracy.
SPECIFICATIONS
Recommended operating temperature range : 5ºC to 40ºC
Temperature measuring range:
Indoor : -9.9ºC to +59.9ºC with 0.1ºC resolution
(“OF.L” displayed if outside this range)
Outdoor : -39.9ºC to +59.9ºC with 0.1ºC resolution
(“OF.L” displayed if outside this range, “---“ displayed if no transmitter signal)
Humidity measuring range:
Indoor humidity range : 20% to 95% with 1% resolution
(Display “- -“ if temperature is OL.F; display “19%“ if < 20% and
Outdoor humidity range : 1% to 99% with 1% resolution (Display “- -“ if outside
Data checking intervals:
Indoor temperature checking interval : every 16 seconds
Outdoor temperature reception : every 4 seconds
Transmission range : up to 100 meters (open space)
Power consumption (alkaline batteries recommended):
Weather station : 3 x AAA, IEC, LR3 1.5V
Transmitter : 2 x AAA, IEC, LR3, 1.5V
Dimensions (L x W x H):
Weather station : 170.8 x 28.3 x 127mm
Transmitter : 36 x 16 x 102.6 mm
LIABILITY DISCLAIMER:
•
The electrical and electronic wastes contain hazardous substances. Disposal of
electronic waste in wild country and/or in unauthorized grounds strongly damages the
environment.
•
Please contact your local and/or regional authorities to retrieve the addresses of legal
dumping grounds with selective collection.
•
All electronic instruments must from now on be recycled. User shall take an active part
in the reuse, recycling and recovery of the electrical and electronic waste.
•
The unrestricted disposal of electronic waste may do harm on public health and the
quality of environment.
•
As stated on the gift box and labeled on the product, reading the “User manual” is
highly recommended for the benefit of the user. This product must however not be
thrown in general rubbish collection points.
•
The manufacturer and supplier cannot accept any responsibility for any incorrect
readings and any consequences that occur should an inaccurate reading take place.
•
This product is designed for use in the home only as indication of the temperature.
•
This product is not to be used for medical purposes or for public information.
•
The specifications of this product may change without prior notice.
•
This product is not a toy. Keep out of the reach of children.
•
No part of this manual may be reproduced without written authorization of the
manufacturer.
R&TTE Directive 1999/5/EC
Summary of the Declaration of Conformity: We hereby declare that this wireless transmission device
does comply with the essential requirements of R&TTE Directive 1999/5/EC.
“96%” if > 95%)
temperature is OF.L; display 1% if < 1% and 99% if > 99%)
31