Technogym Excite Synchro User Manual

EXCITE
Synchro
User manual

Contents

Manufacturer and equipment identification .............................................. 3
Description of the equipment .................................................................... 5
Technical data ......................................................................................... 15
Accessories ............................................................................................. 18
Safety devices and notices ..................................................................... 19
Place of installation ................................................................................. 21
Unpacking ............................................................................................... 22
Moving the equipment ............................................................................ 23
Levelling .................................................................................................. 24
Electrical connection (700 and 500 versions) .......................................... 25
Connection to another device ................................................................. 27
Routine maintenance ............................................................................. 29
Changing the fuses (700 and 500 versions) ............................................ 31
Recharging the battery (700 SP and 500 SP versions) ........................... 32
Troubleshooting ....................................................................................... 33
Technical assistance ............................................................................... 36
Storage .................................................................................................... 37
Disposing of the equipment .................................................................... 38
Switching on and off ............................................................................... 39
Monitoring the heart rate ......................................................................... 41
Ergonomic positioning on the equipment ............................................... 44
Synchro Excite
2
Manufacturer and equipment identication
B HA
IE I
G
F
A - Manufacturer’s name and address B - Description of product C - Electrical specifications and type of fuses
(700 and 500 versions)
D - Equipment classification E - CE Mark
The values stated in the illustration are purely indicative; refer to the label attached to the equipment or the data in Technical data section for the correct information.
F - Serial number and date of manufacture G - Certification mark for the USA and
Canada
H - Product code I - Tells you to consult the User manual
Synchro Excite
3
Manufacturer and equipment identication
Equipment with codes DA52M..., DA53M..., DA58M..., DA59M... are intended for medical use and have been designed and built for use in outpatient clinics, hospitals, clinics and sport centres, for muscular therapy and rehabilitation.
Equipment with codes DA52M..., DA53M..., DA58M..., DA59M... can be used by or close to children, invalids, disabled persons or people with evident physical problems only under close supervision of a doctor or a qualified professional.
Synchro Excite
4

Description of the equipment

Control panel
Levers
Fast Track Control
Sensors
Fixed handles
Pedals
Bases
Reading stand
Tray
TGS key reader
Control panel: controls all available functions, from setting up workout programs to viewing messages and related workout information.
Synchro Excite
5
Description of the equipment
Control panel
Levers
Fast Track Control
Sensors
Fixed handles
Pedals
Bases
Reading stand
Tray
TGS key reader
Levers: these can be grasped by the user to perform the exercise with arm movements. The 700 and 700 SP versions have sensors for monitoring the heart rate (hand sensor) and the Fast Track Control to change the effort level.
Synchro Excite
6
Description of the equipment
Control panel
Levers
Fast Track Control
Sensors
Fixed handles
Pedals
Bases
Reading stand
Tray
TGS key reader
Levers: these can be grasped by the user to perform the exercise with arm movements. The 700 and 700 SP versions have sensors for monitoring the heat rate (hand sensor) and the Fast Track Control to change the effort level.
Synchro Excite
7
Description of the equipment
Control panel
Levers
Fast Track Control
Sensors
Fixed handles
Pedals
Bases
Reading stand
Tray
TGS key reader
Sensors: levers and fixed handles have sensors for monitoring the heat rate (hand sensor), in the 700 and 700 SP versions of the equipment.
Synchro Excite
8
Description of the equipment
Control panel
Levers
Fast Track Control
Sensors
Fixed handles
Pedals
Bases
Reading stand
Tray
TGS key reader
Fixed handles: these can be grasped by the user during the workout. The 700 and 700 SP versions have sensors for monitoring the heart rate (hand sensor).
Synchro Excite
9
Description of the equipment
Control panel
Levers
Fast Track Control
Sensors
Fixed handles
Pedals
Bases
Reading stand
Tray
TGS key reader
Pedals: the special configuration of the pedals permit the ankles to work under optimum conditions.
Synchro Excite
10
Description of the equipment
Control panel
Levers
Fast Track Control
Sensors
Fixed handles
Pedals
Bases
Reading stand
Tray
TGS key reader
Bases: support the equipment frame and components.
Synchro Excite
11
Description of the equipment
Control panel
Levers
Fast Track Control
Sensors
Fixed handles
Pedals
Bases
Reading stand
Tray
TGS key reader
Reading stand: for standing magazines or books on.
Synchro Excite
12
Description of the equipment
Control panel
Levers
Fast Track Control
Sensors
Fixed handles
Pedals
Bases
Reading stand
Tray
TGS key reader
Tray: for standing the water bottle or other useful items on during the workout.
Synchro Excite
13
Description of the equipment
Control panel
Levers
Fast Track Control
Sensors
Fixed handles
Pedals
Bases
Reading stand
Tray
TGS key reader
TGS key reader: for the TGS key (optional).
Synchro Excite
14

Technical data

Synchro 700 and 500
Power supply 100÷240 Vac ±10% 50/60 Hz Maximum braking power 500 W at 120 spm Minimum braking power 20 W at 60 spm Mains power input 65 VA max (160 VA max with Unity) Fuses 2 x 3.15A (F) Weight of equipment 148 kg (326 lb) Maximum user weight 180 kg (397 lb) User heigh for which 155 cm÷205 cm (6"÷8")
performance indicated is guaranteed Time 0÷999 min ± 1% Distance 0÷99.99 km ± 5% (0÷99.99 mls ± 5%) Protection grade IP 20 Electric isolation class Class I Marks and Certificates CE - UL
(*)
(*)
Only if the symbol is present on the equipment identification label.
cont.segue
Technical data
Synchro 700 SP and 500 SP
Maximum braking power 500 W at 120 spm Minimum braking power 45 W at 60 spm Weight of equipment 150 kg (331 lb) Maximum user weight 180 kg (397 lb) User heigh for which 155 cm÷205 cm (6"÷8")
performance indicated is guaranteed Time 0÷999 min ± 1% Distance 0÷99.99 km ± 5% (0÷99.99 mls ± 5%) Protection grade IP 20 Electric isolation class Class II Marks and Certificates CE - UL
(*)
Only if the symbol is present on the equipment identification label.
(*)
cont.segue
Technical data
752 mm
(30")
2042 mm
(80")
1609 mm
(63")
Synchro Excite
17

Accessories

A Set of wrenches
B User manual
C Warranty certificate
D CEE Power Supply cable with SH socket (700 and 500 versions)
E Two replacement fuses (3.15A (F) (700 and 500 versions)
F Chest band with transmitter for heart rate monitor (optional)
A
B
E
F
Synchro Excite
18

Safety devices and notices

B C
A
A Fixed guard: guards against access to the inside of the equipment.
B Main switch: turns the equipment’s power on and off (700 and 500 versions).
C Fuses: they protect the equipment’s electrical parts (700 and 500 versions). When the current reaches an excessive value,
the fuses melt thus protecting the internal electronics.
Synchro Excite
19
Safety devices and notices
Warning
Please read the adhesive labels on the equipment, which provide information about possible risks and hazards.
In the 700 and 500 versions:
E The label affixed to the frame under the control panel states the
electrical specifications.
F The label, which can be affixed close to the main switch, states safety
indications.
G The label which can be affixed to the power supply cable states the
electrical specifications for the cable.
E
G
F
CAUTION: do not connect a device with load exceeding 7 A
CAUTION: do not connect to a circuit operating at more than 150V to ground
CAUTION: risk of electric shock. Do not disconnect under load
Synchro Excite
20

Place of installation

To ensure that exercising with Synchro is easy, safe and effective, the place where it is used should comply with certain specific requirements; in particular, before choosing the place where the equipment will be installed, please ensure that the following conditions are satisfied:
- the temperature is between +10°C and +25°C;
- enough air is circulating to keep humidity during exercise to between 20% and 90%;
- the lighting is good enough to make the area safe and relaxing place to exercise in;
- plenty of free space around each item of equipment;
- that the floor is flat, stable and vibration-free, and strong enough to bear the weight of the equipment plus user.
The place of installation must comply with all the suitability requirements laid down in current legislation on this matter.
Equipment not suitable for use in the presence of anaesthetic mixtures inflammable in air, oxygen or nitrous oxide.
In order to guarantee the performance indicated by the manufacturer, you are advised against using the equipment in zones with high short-wave presence or similar.
Synchro Excite
21

Unpacking

Depending on the country of destination, Synchro can either come partially assembled in a cardboard pack attached to a pallet, or fully assembled, wrapped in a transparent plastic sheet and attached to a pallet.
The packed material can be lifted and carried with normal lifting equipment. The instructions are printed directly on the pack.
In order to ensure the safety of persons and property, you should think carefully about what lifting and transport equipment to use, in relation to the equipment’s place of destination.
As stated in the instructions on the pack, to unpack equipment delivered in a cardboard pack, remove the staples that attach the external packaging to the pallet, and then lift up the pack.
Check the pack visually to make sure it is in a good, complete state.
Remove the fasteners and place the contents of the pack on the ground.
The Assembly instructions are enclosed with this guide.
Warning
Observe the legally stated urban waste disposal procedures when disposing of the packaging material.
Synchro Excite
22

Moving the equipment

The equipment has two fixed rear wheels. To move the equipment, lift it up slightly, as shown in the illustration, and push it forwards and backwards.
Given the weight of the equipment, we recommend that more than one person be involved in lifting it.
If wheels cannot be used on the floor, move the equipment with normal lifting and transport methods.
Warning
Lift the equipment by holding onto the frame and not the levers or the control panel.
Take great care when moving the equipment and positioning it on the ground, as it may overbalance.
Synchro Excite
23

Levelling

The equipment is levelled by adjusting the two front feet and the central foot:
- loosen the lock nut (B) and screw the front feet (A) in or out until the frame is in a stable position;
- tighten up the lock nut (B) after adjusting.
B
A
A
Synchro Excite
24

Electrical connection (700 and 500 versions)

Before connecting the equipment to the mains power supply, ensure that the electrical system specifications comply to binding regulations. Check the mains power supply specifications on the label applied to the frame under the control panel.
Danger
The wall socket must be located in a place where the plugging and unplugging can be done easily and safely.
When plugging in, the switch on the equipment must be in the 0 position (i.e. the equipment must be switched off).
Plug the power cable first into the equipment socket and then into the wall socket.
Warning
Check the state of the power supply cable periodically.
Synchro Excite
25
Electrical connection (700 and 500 versions)
Danger
The power supply socket must be grounded . If not, a ground connection must be installed by a qualified electrician before connecting the equipment to the electricity mains.
The product must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. The product is equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
Danger
Improper connection of the equipment-grounding conductor can result in a risk of electrical shock. Check with a qualified electrician or serviceman if you are in doubt as to whether the product is properly grounded. Do not modify the plug provided with the product; if it will not fit in the outlet, have a proper outlet installed by a qualified electrician.
Synchro Excite
26

Connection to another device

The equipment can be connected to an audio/video reception device such as the Cardio Theater. Besides, if the equipment has not TV, it can be connected to a network of devices conforming to the CSAFE protocol.
Warning
The devices connected must comply with international standards.
Equipment with codes DA52M..., DA53M..., DA58M..., DA59M... can be connected to devices conforming to the CSAFE protocol only for setting and maintenance functions. Additional devices connected to the digital interface must conform to the respective IEC standards (that is IEC 60950 for information technology equipment and IEC 60601-1 for medical electrical equipment). Whoever connects additional equipment to the input or output signal ports, configures a medical system and therefore is responsible for the system’s conformity to the IEC 60601-1 standard about systems. Consult the technical support department or your local representative if you have any doubts.
Synchro Excite
27
Connection to another device
If the equipment has the TV, connect the aerial cable to the equipment and to the wall socket. Use an RF coaxial cable for the connection with an F type of connector for the equipment. The wall socket of the aerial cable must be positioned so that the plug can be easily inserted and removed.
A network socket can be found next to the aerial socket for the Ethernet connection.
Synchro Excite
28

Routine maintenance

As the equipment is used in a sports centre by more than one person, it should always be kept clean and free of dust, in accordance with normal hygiene and sanitary rules.
To clean the control panel, proceed as follows:
- turn the equipment off by switching the switch to the 0 position (700 and 500 versions);
- unplug the equipment power cable from the wall socket (700 and 500 versions);
- clean the control panel with a damp, but not wet, cloth.
Every week, clean the equipment completely:
- with the equipment turned off, clean the external parts with a damp sponge;
- move the equipment to one side so that you can vacuum clean underneath it.
Do not use chemical products or solvents.
Warning
Do not rub too hard on the control panel and diagrams, or on the written instructions on the stickers.
The safety of the equipment is assured only on the condition that it is carefully inspected every two weeks for any signs of damage and/or wear.
For maintenance actions not described in this manual, call in the Technogym Technical Service.
Synchro Excite
29
Routine maintenance
Danger
The routine maintenance, adjustment and lubrication jobs must be performed by the Technogym Technical Support Service.
Before starting any job, turn the equipment off by switching the switch to the 0 position and unplug the power cable from the wall socket.
Synchro Excite
30

Changing the fuses (700 and 500 versions)

Danger
Before changing the fuses, switch the equipment off by switching the switch to 0 and unplug the power cable plug from the wall socket.
Remove the fuse holder, to the right of the switch, by pushing the lever.
Replace the blown fuse with a new one as supplied (3.15A (F).
Fit the fuse holder back into its housing, making sure it clicks in properly.
Danger
If no more of the supplied fuses are available, use certified fuses with identical electrical specifications (3.15A (F) for the replacement.
Synchro Excite
31

Recharging the battery (700 SP and 500 SP versions)

The 700 SP and 500 SP versions have to be kept moving to keep them turned on. If, when you stop moving, the control panel switches off without warning, the battery will have to be recharged.
If, 30 seconds after starting movement, the resistance of the equipment is exceptionally high even at effort level 1, recharge the battery with the charger.
Warning
Do not use the equipment while the battery is recharging.
Charger electrical specifications:
Input 100÷240 Vac 0,8 A 50/60 Hz Output 15 V dc 24W
Class II
Warning
Only use devices that comply with applicable standards.
Synchro Excite
32

Troubleshooting

Below is a list of problems that may arise during normal use of the equipment. If the described remedies do not solve the problem, contact the Technical Support Service.
Problem Cause
Remedy
Equipment doesn’t switch on
Mains power failure (700 and 500 versions).
Check the power supply at the wall socket used by the equipment by plugging in an appliance that definitely works.
Power supply cable damaged (700 and 500 versions).
Contact the Technogym Technical Support Service.
Installation problems with the power supply cable (700 and 500 versions).
Check the connection.
Burnt-out fuses (700 and 500 versions).
To replace the blown fuse with a spare (3.15A (F) contact Technogym Technical Support Service.
The control panel connector has been accidentally disconnected.
Contact the Technogym Technical Support Service.
Synchro Excite
33
Troubleshooting
Problem Cause
Remedy
Too noisy Equipment not properly levelled.
Check the position and level the adjustment feet.
Damaged bearings.
Contact the Technogym Technical Support Service.
Worn belt.
Contact the Technogym Technical Support Service.
Data incorrect or unreliable with equipment running
Blocked key on keypad.
If the problem persists, contact the Technogym Technical Support Service.
Equipment next to source of radio interference (e.g. electrical domestic appliances).
Move the equipment to another place or move the domestic appliances.
An internal connector has become accidentally disconnected.
Contact the Technogym Technical Support Service.
Internal contact in control panel.
Contact the Technogym Technical Support Service.
Synchro Excite
34
Troubleshooting
Problem Cause
Remedy
Problems in monitoring heart rate with the chest band
Other transmitters situated nearby.
Move the equipment far enough away to stop signal interference (minimum distance between two units 80 cm).
Strong interference sources nearby.
Find the interference source (e.g. an electrical domestic appliance) and move it away, or move the equipment.
Worn heart rate monitor chest band.
Change the chest band.
Chest band transmitter not making proper skin contact.
Dampen the inside of the chest band with water.
Control panel not working properly.
Contact the Technogym Technical Support Service.
Damaged transmitter.
Change the chest band.
Synchro Excite
35

Technical assistance

The Technogym Technical Support Service provides:
Technogym Technical
- telephone consultation
- information about which services are covered by the warranty and which must be paid for
- on-site servicing
- supply of original spare parts.
When you contact the Technogym Technical Support Service you must give the following information:
- model,
email: support@technogym.com
Support Service
tel: 0547 650650
fax: 0547 650150
- date of purchase,
- serial number,
- precise description of the problem.
Warning
Work on the equipment by persons unauthorised by Technogym invalidates the warranty.
Technogym supplies the electrical and wiring diagrams to companies with technical support.
Synchro Excite
36

Storage

If a long period of non-use is expected, you are advised to store the equipment in the following way:
- in a clean dry place, with a dust cover;
- at a room temperature between -10°C and 70°C and relative humidity between 20% and 90%.
For better storage, use the original packing materials.
Synchro Excite
37

Disposing of the equipment

Always make sure that the equipment cannot become a hazard in any way, and do not leave it in places where children play. As a precaution, when the equipment is unused for a long time or when you want to dispose of it, unplug it from the mains.
Disposing of the equipment on open ground, in public areas, or in private areas used by the public is prohibited.
The equipment is made from recyclable materials such as steel, aluminium and plastic, which must be disposed of in the manner prescribed by the urban refuse collection regulations in force, by specialist environmental firms.
Disposing of the battery
The battery is made of non-recyclable materials: do not discard it in the environment.
Contact specialist urban and environmental cleansing agencies for disposing of the battery.
Disposing of the chest band
The chest band, which transmits heart rate data, is not made of recyclable materials and therefore must not be disposed of on open ground.
Contact a company specialized in urban and environmental sanitation.
Synchro Excite
38
Switching on and o
To turn 700 and 500 versions of the equipment on, switch the switch to “I” position. To turn the 700 SP and 500 SP versions on, begin moving.
When switched on, a beep sounds and all the control panel LEDs light up.
After a quick system check (reset), the equipment is ready for use.
In this mode, the following functions are enabled:
- calculation of heart rate, if measured;
- reading of access codes for configuration menu (see the Configuration Menu section in the software part).
Synchro Excite
39
Switching on and o
To turn 700 and 500 versions of the equipment off, switch the main switch to the “0” position.
If the equipment isn’t going to be used for a long time, as well as turning it off you should also pull the plug out of the wall socket.
Warning
The switch is for turning the equipment on and off but does not isolate it completely from the mains voltage, even in the “0” position (off). For complete isolation you must unplug the power supply plug.
To turn the 700 SP and 500 SP versions off, simply stop moving.
The equipment must be switched off only at the end of the exercise, when in standby.
Synchro Excite
40

Monitoring the heart rate

The equipment is able to measure heart rate trends, in two different ways:
- with a device applied to the fixed handle or to the levers (hand sensor), that switches on when you grip the handles or levers in the sensor region (in 700 and 700 SP versions);
- with a chest band with a heart rate transmitter (Polar T31).
There must be no more than one transmitter in the reception range: otherwise the receiver may receive different signals at the same time and give incorrect heart readings. If there are several equipment units with heart rate receivers in the same area, the recommended minimum distance between them is 80 cm.
Synchro Excite
41
Monitoring the heart rate
Heart rate readings will not be accurate near electromagnetic radiation sources (TVs, cellphones, etc.).
Should you have any doubts about the accuracy of the readings, contact the Technical Support Service.
The following table shows the optimum heart rate levels in relation to age and the goal to be achieved. Theoretical maximum heart rate (100%) is calculated on the basis of age using the formula: 220 - age.
Heart rate per minute
Area reserved for competitive athlete’s
workouts (requiring a doctor’s certificate)
Aerobic zone with a primarily cardio-
circulatory component (keep heart rate between 70% and 90%)
Age
Aerobic zone primarily using fats as energy
source (keep heart rate between 60% and 70%)
Zone of little training interest
Synchro Excite
42
Monitoring the heart rate
To read the graph, simply find your age on the horizontal axis and scan up the vertical until you reach the 60%, 70% and 90% values.
Aerobic exercise performed at a heart rate between 60% and 70% mainly burns fat as an energy source.
When doing aerobic exercise at a heart rate of 70% to 90% the cardiocirculatory component prevails.
For example, if someone aged 30 wants to burn off fat, the heart rate during exercise should be kept to between 114 (60%) and 133 (70%); if he or she wants to improve cardio-respiratory capacity, the heart rate should be kept to between 133 (70%) and 171 (90%).
Danger
During a workout it is very important that your heart rate never goes above 90% of your maximum rate (unless you are an athlete engaged in competitive sport).
Warning
The sole function of the heart rate monitor is to display the heart rate during exercise and cannot be used for medical cardiac diagnoses of any kind. The heart rate shown on the display is purely indicative and cannot be considered absolutely certain.
Synchro Excite
43

Ergonomic positioning on the equipment

Step onto the equipment from one side and put one foot on each pedal. Grasp a fixed handle with one hand and set the program with the other on the control panel.
To perform the movement with your lower limbs only, hold the fixed handles. To perform the movement with your upper limbs as well, hold the levers.
At the beginning move slowly until you become familiar with the equipment and acquire balance. It is important that you get used to the movement without leaning forward and assuming unnatural positions.
Once you become more confident, gradually increase the effort level. Constantly check your position: head held high, shoulders in line with the hips, abdomen sucked in and trunk erect. To maintain
correct posture you must keep legs and feet parallel and gaze straight ahead.
Warning
Any distractions in the area around the equipment may cause the user to lose his/her balance.
Synchro is to be used solely for its intended purpose, i.e. for aerobic exercise of the legs and arms. Any other use of the equipment is to be considered improper and therefore dangerous.
Synchro Excite
44
Synchro Excite_uk-AH 0SM00421
Loading...