Introduction
SineUPS is an uninterruptible power supply, guaranteeing constant powering to the
electric loads connected. In case of mains failure (power cut or instability) SineUPS
generates pure sine wave and can work continuously until the battery runs out. The output
voltage has the same form as the mains voltage meaning that the connected loads will
work just as efficiently as being powered from the mains network.
When the device is powered by regular mains voltage, it keeps the battery fully charged so
it can provide its maximum capacity when needed.
Installation
Warning!
SineUPS works at high voltage and requires special attention when its being
connected!
The device is designed for home use only! Please make sure there is enough
space around it to vent properly, do not install it in a place exceeding the operating
temperature and humidity!
Mounting
The device can be mounted on a horizontal surface or vertically on a wall. In order to
mount it vertically, install 4 screws on the wall (3.5 x 35 mm), so the unit can be hanged as
depicted on the drawing below.
2
![](/html/2b/2b97/2b9744d06112e4ce988f6f749c103642aed7e23572fa4acd834f9ca52357df22/bg3.png)
Connection
1. Connect the load's power plug to the OUTPUT socket of the UPS.
2. For models S100 and S200 an external battery has to be connected (models S100a
and S100a+ have integrated battery, so skip this step, as S100a+ has an option for
connecting external battery so the step is not mandatory). Connect the battery to the
BATTERY terminal, paying attention to the polarity – the + cable goes to the + terminal of
the battery. Depending on the particular type of installed battery, there is possibility that
some harmful gases can be released and in that case it is recommended to install the
device in a proper location.
3. Verify that the load and battery are properly connected. Plug the power plug of the
UPS (INPUT terminal) to mains socket. If mains is present, the device will start charging the
battery. If in the electrical installation a common neutral is used instead of protective
earth (PE), it is recommended to cut off the plug and power the device using hard wiring –
brown wire to phase and blue to neutral.
4. Turn on the device to power the load connected by pressing the power on button
(see next chapter Operation).
3