Techni-Lux DL-LEDPAR1C36O/B, DL-LEDPAR1C36O/S User Manual

Information specifically for:
DL-LEDPAR1C36O/B - Black DL-LEDPAR1C36O/S - Silver
This manual contains important information.
Please read before operating fixture.
V2
IMPORTANT INFORMATION
Save original packing and documentation for warranty, service and return issues.
Limited Warranty: This warranty covers defects or malfunctions in this equipment. This warranty lasts for a period of one year from date of purchase. It is the owner’s responsibility to provide invoices for proof of purchase, purchase date and dealer or distributor. If purchase date can not be provided, warranty period will start at manufacture date. It is the sole discretion of Techni-Lux to repair or replace parts or equipment. All shipping will be paid by purchaser. This warranty does not cover lamps, fuses, belts, power semiconductors, relays, cleaning, standard maintenance adjustments or normal wear items or any problem resulting from the following: improper wiring, incorrect voltage (including low or over voltage conditions and lightning), abuse, misuse, improper maintenance or an act of God or damage resulting from shipping. Warranty will be null and void if the product is altered, modified, misused, damaged, or subjected to unauthorized repairs. Lamps are covered by relevant manufacturer warranty. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Any liability for consequential and incidental damages is expressly disclaimed. No other warranty, expressed or implied is made. Techni-Lux liability in all events is limited to, and shall not exceed, the purchase price paid.
Returning equipment and Repairs: All returns must be accompanied by a Return Merchandise Authorization (RMA) number and sent pre-paid. Contact the dealer or Techni-Lux directly to obtain an RMA. The RMA number must be clearly listed on the shipping label. Due care must be exercised in packing all merchandise to be returned. All repairs must be accompanied by a written explanation of the claimed problem or error encountered. Techni-Lux is solely responsible for determining a product’s eligibility for coverage under warranty. If returning for consideration of credit, all accessories and documentation, original protective material and cartons must be included and the equipment, packing and carton must be in new resalable condition. Credit for returned merchandise will be issued at the lowest current price and is subject to a restocking fee. No returns accepted on discontinued items. Techni-Lux is not responsible for merchandise damaged in transit and reserves the right to refuse any return that is damaged by the carrier, not accompanied by a Return Authorization Number (RMA#) or sent by freight collect.
Claims: All claims must be made within seven (7) days of receipt of merchandise. Any physical damage must be reported to carrier upon receipt of merchandise.
Please record the following information for future reference: Model Number (circle): DL-LEDPAR1C36O/B or DL-LEDPAR1C36O/S
Serial Number: ________________________________________
Dealer: ______________________________________________
Date of Purchase: ______________________________________
www.Techni-Lux.com
2
Table of Contents
Specifications............................................................................................................................. 4
Unpacking................................................................................................................................... 5
Power .......................................................................................................................................... 5
Mounting ..................................................................................................................................... 5
Basic Reference ......................................................................................................................... 6
Setup and Operation Modes (LED Segment Display) ............................................................. 6
Control Panel Menu ................................................................................................................... 6
Control Panel Menu Table........................................................................................................ 7
DMX-512 Control ........................................................................................................................ 7
DMX Data Connection.............................................................................................................. 8
Data Terminator ....................................................................................................................... 8
Adapter 5-to-3 pin..................................................................................................................... 8
DMX Start Address................................................................................................................... 9
DMX Channel Assignments....................................................................................................... 9
3 Channel Mode ....................................................................................................................... 9
4 Channel Mode ....................................................................................................................... 9
5 Channel Mode ..................................................................................................................... 10
6 Channel Mode ..................................................................................................................... 10
Channel Values and Functions – 6 Channel Mode ................................................................ 10
CH 1 : Master Dimmer.......................................................................................................... 10
CH 2 : Red............................................................................................................................ 10
CH 3 : Green ........................................................................................................................ 10
CH 4 : Blue ........................................................................................................................... 11
CH 5 : Color Macro/Scroll..................................................................................................... 11
CH 6 : Strobe........................................................................................................................ 12
Maintenance ............................................................................................................................. 13
Accessory Items (sold separately) ......................................................................................... 13
Troubleshooting....................................................................................................................... 14
DMX-512 Background .............................................................................................................. 14
3
Specifications
Fixture Overview
RGB color mixing with intensity and strobe effects
36 total high power 1 watt LEDs: 12 red, 12 green, 12 blue
Beam Angle – 15°
Rugged Heavy Duty Aluminum Housing
Operating modes: DMX, Scene Memory, Chases, Sound Active, Master/Slave
Precise DMX control using 6 channels
3 Pin DMX connectors
Segmented LED display menu for settings
Optional beam angle lenses: 30, 45, 60
Dual yoke for floor or hang mounting
½” Clamp mounting hole
Physical
Color Black or Silver Size 9.5” x 11.0” x 7.25” Weight 8.5 lbs (3.86 kgs) Housing Material Aluminum
Environmental
Location Indoor / Outdoor IP65 Max. ambient temperature 105°F (40°C) Min. distance to flammable surface 3.3ft (1m) Min. distance to illuminated surface 1ft (0.3m)
Electrical
Voltage Auto Ranging 80 - 240vAC, 50-60Hz Rated Power 50W Fuses Internal 1 amp mini size: 5x20mm
Control
Digital Protocol USITT DMX512 (1990) Channels 3, 4, 5, or 6 maximum Data I/O 3 Pin XLR (Cannon) Modes DMX512 or Stand-Alone
Optics
Light Source 36 RGB 1 watt LEDS at 350ma Beam Angle 15°
Rigging
Orientation Any Mounting Points Dual adjustable yokes with 1/2” (13mm) mounting hole
4
Unpacking
Immediately upon receipt, carefully unpack and inspect the fixture to verify that all parts are present and have been received in good condition. If any parts appear damaged from shipping or the shipping carton shows signs of mishandling, notify the shipper immediately. Retain carton and all packing material for inspection. In the event that the merchandise is to be returned, the original carton and packing must be used. The customer will be billed for a new carton and packing if merchandise is received without the original carton and packing.
Claims
Physical damage must be reported to the Freight Carrier or Shipping Company upon receipt of merchandise. Damage incurred in shipping is the responsibility of the Freight Carrier or Shipping Company. It is the customer’s obligation in the event that merchandise is received damaged, to notify the Freight Carrier or Shipping Company immediately. All other claims not related to damage incurred during shipping must be made to the Dealer or Distributor within 7 days of receiving merchandise.
Returns
Returned merchandise must be in the original packing with a Return Merchandise Authorization number (RMA) clearly listed on the shipping label. Items sent by Freight Collect or without a RMA number will be refused. Call your sales person and request a RMA prior to shipping. Be prepared to provide the model number, serial number and description of the nature of the return. Shipping damage resulting from inadequate packaging is the customer’s responsibility. Customer will be charged additional shipping charges to return products received in non original packing and or cartons.
Power
Do not apply power to the fixture until power source is verified. For protection against electric shock, fixture must be connected to suitable earth ground.
Make sure fixture is disconnected from power mains before any service.
The mains voltage and frequency of this fixture is internally set. It can either be set to 120v or 230v AC 50/60Hz. The listed power rating is its average wattage under normal conditions. All fixtures must be powered directly from a switched circuit. This fixture cannot be run on a rheostat or dimmer circuit even if used solely for a 0% to 100% switching. Before applying power to a fixture, check that the fixture’s input voltage matches the power source voltage. Consult a qualified electrician if there are any concerns about proper connection to power.
Mounting
Always consult a qualified professional when rigging. Consider access for routine maintenance when selecting a mounting position. This fixture may be mounted in any position provided there is adequate room for movement and ventilation. Mount the fixture securely using a mounting clamp and a safety cable. This fixture features dual yokes making it useful for floor standing at different angles. Always keep cords out of the way, thus preventing any trip hazards. Secure all cables properly. Do not mount where the fixture will be exposed to rain, high humidity, extreme temperature changes or restricted ventilation. Do not obstruct any vents.
5
Loading...