Techni-Lux DL-LEDPANEL36C/B, Ultra LED Series, DL-LEDPANEL36C/W, DL-LEDPANEL36W/W, DL-LEDPANEL36W/B User Manual

...
Information specifically for:
DL-LEDPANEL36C/B – Black with RGB LEDS DL-LEDPANEL36C/W White with RGB LEDS
DL-LEDPANEL36W/B – Black with White/Amber LEDS DL-LEDPANEL36W/W – White with White/Amber LEDS DL-LEDPANEL36UV/B – Black with UV LEDS
V2.0
Please read before operating fixture.
IMPORTANT INFORMATION
Save original packing and documentation for warranty, service and return issues.
Limited Warranty: This warranty covers defects or malfunctions in this equipment. This warranty lasts for a period of one year from date of purchase. It is the owner’s responsibility to provide invoices for proof of purchase, purchase date and dealer or distributor. If purchase date can not be provided, warranty period will start at manufacture date. It is the sole discretion of Techni-Lux to repair or replace parts or equipment. All shipping will be paid by purchaser. This warranty does not cover lamps, fuses, belts, power semiconductors, relays, cleaning, standard maintenance adjustments or normal wear items or any problem resulting from the following: improper wiring, incorrect voltage (including low or over voltage conditions and lightning), abuse, misuse, improper maintenance or an act of God or damage resulting from shipping. Warranty will be null and void if the product is altered, modified, misused, damaged, or subjected to unauthorized repairs. Lamps are covered by relevant manufacturer warranty. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Any liability for consequential and incidental damages is expressly disclaimed. No other warranty, expressed or implied is made. Techni-Lux liability in all events is limited to, and shall not exceed, the purchase price paid.
Returning equipment and Repairs: All returns must be accompanied by a Return Merchandise Authorization (RMA) number and sent pre-paid. Contact the dealer or Techni-Lux directly to obtain an RMA. The RMA number must be clearly listed on the shipping label. Due care must be exercised in packing all merchandise to be returned. All repairs must be accompanied by a written explanation of the claimed problem or error encountered. Techni-Lux is solely responsible for determining a product’s eligibility for coverage under warranty. If returning for consideration of credit, all accessories and documentation, original protective material and cartons must be included and the equipment, packing and carton must be in new resalable condition. Credit for returned merchandise will be issued at the lowest current price and is subject to a restocking fee. No returns accepted on discontinued items. Techni-Lux is not responsible for merchandise damaged in transit and reserves the right to refuse any return that is damaged by the carrier, not accompanied by a Return Authorization Number (RMA#) or sent by freight collect.
Claims: All claims must be made within seven (7) days of receipt of merchandise. Any physical damage must be reported to carrier upon receipt of merchandise.
Please record the following information for future reference:
Model Number (circle): DL-LEDPANEL36C/B, DL-LEDPANEL36C/W,
DL-LEDPANEL36W/B, DL-LEDPANEL36W/W, DL-LEDPANEL36UV/B
Serial Number: ________________________________________
Dealer: ______________________________________________
Date of Purchase: ______________________________________
www.Techni-Lux.com
2
Table of Contents
Specifications ............................................................................................................................. 4
Unpacking ................................................................................................................................... 5
Purpose of Manual ...................................................................................................................... 5
Power ........................................................................................................................................... 5
Mounting ..................................................................................................................................... 6
Optional Mounting Bracket ........................................................................................................ 6
Basic Reference .......................................................................................................................... 6
Basic Setup Wiring Diagrams .................................................................................................... 7
Operation Modes (LED Segment Display) ................................................................................ 8
Display Panel Navigation ........................................................................................................... 8
Setting the Start Address for DMX512 Control .......................................................................... 8
Setting P(x,y) Standalone Program ........................................................................................... 9
Setting Master/Slave ................................................................................................................. 9
P(x,y) Standalone Program Chart (RGB models only) .............................................................. 9
DMX-512 Control ....................................................................................................................... 10
DMX Data Connection ............................................................................................................ 10
Data Terminator ...................................................................................................................... 10
Adapter 5-to-3 pin ................................................................................................................... 10
DMX Start Address ................................................................................................................. 11
DMX Channel Assignments ..................................................................................................... 11
3 Channel Mode ...................................................................................................................... 11
Channel Values and Functions – 3 Channel Mode ................................................................. 12
CH 1 : Red ............................................................................................................................ 12
CH 2 : Green ......................................................................................................................... 12
CH 3 : Blue ............................................................................................................................ 12
CH 1 : White .......................................................................................................................... 13
CH 2 : White .......................................................................................................................... 13
CH 3 : Amber ........................................................................................................................ 13
CH 1 : UV .............................................................................................................................. 13
CH 2 : UV .............................................................................................................................. 13
CH 3 : UV .............................................................................................................................. 13
Maintenance .............................................................................................................................. 14
Accessory Items (sold separately) .......................................................................................... 14
Troubleshooting ....................................................................................................................... 15
DMX-512 Background ............................................................................................................... 15
3
Specifications
Fixture Overview
RGB color mixing, White/Amber variable white or UV Blacklight Rugged Heavy Duty Aluminum Housing Operating modes: DMX, or Standalone Master/Slave 3 Pin DMX connectors Segmented LED display menu for settings Integrated power supply in base Floor standing, wall or ceiling mounting holes Adjustable panel angle
Physical
Color Black or White Size 13.11" w x 9" h x 5.5" d Weight 9.2 lbs (4.18 kgs) Housing Material Aluminum
Environmental
Location Indoor / Outdoor IP65 Max. ambient temperature 105°F (40°C) Min. distance to flammable surface 3.3ft (1m) Min. distance to illuminated surface 1ft (0.3m)
Electrical
Voltage Auto Ranging 100 - 265vAC, 50-60Hz Rated Power 40W Fuses Internal Rating Approval cETLus, CE
Control
Digital Protocol USITT DMX512 (1990) Channels 3 Data I/O 3 Pin XLR (Cannon) Modes DMX512 or Stand-Alone
Optics
Light Source 36 x 1 watt LEDS at 300ma Output RGB (lumens/watt) 12 x 33Lm/W Red, 12 x 44Lm/W Green, 12 x 12Lm/W Blue Output W/A (lumens/watt) 24 x 80Lm/W White 6000k, 12 x 35Lm/W Amber Output UV 36 x UV380-395nm 700-800mW, UV360-375nm 600-615mW Beam Angle Lenses at 15°
Rigging
Orientation Any Mounting Points Dual mounting 8mm wide slotted holes at base of fixture
4
Unpacking
Immediately upon receipt, carefully unpack and inspect the fixture to verify that all parts are present and have been received in good condition. If any parts appear damaged from shipping or the shipping carton shows signs of mishandling, notify the shipper immediately. Retain carton and all packing material for inspection. In the event that the merchandise is to be returned, the original carton and packing must be used. The customer will be billed for a new carton and packing if merchandise is received without the original carton and packing.
Claims
Physical damage must be reported to the Freight Carrier or Shipping Company upon receipt of merchandise. Damage incurred in shipping is the responsibility of the Freight Carrier or Shipping Company. It is the customer’s obligation in the event that merchandise is received damaged, to notify the Freight Carrier or Shipping Company immediately. All other claims not related to damage incurred during shipping must be made to the Dealer or Distributor within 7 days of receiving merchandise.
Returns
Returned merchandise must be in the original packing with a Return Merchandise Authorization number (RMA) clearly listed on the shipping label. Items sent by Freight Collect or without a RMA number will be refused. Call your sales person and request a RMA prior to shipping. Be prepared to provide the model number, serial number and description of the nature of the return. Shipping damage resulting from inadequate packaging is the customer’s responsibility. Customer will be charged additional shipping charges to return products received in non original packing and or cartons.
Purpose of Manual
The purpose of this manual is to explain the necessary steps for using this fixture properly and to assure peak performance of said product functions. It is intended for use as a reference by a fully qualified electrician, technician and lighting professional. This manual should never be considered a substitute for any provision of a regulation, state and/or local code. The responsibility of complying with all state and local laws, ordinances, and regulations in regards to installation, maintenance, and operation of this product lies with the buyer and handler of the product. The instructions and precautions set forth in this manual are not necessarily inclusive of or relevant to all applications. Please read the entire manual to fully understand and safely use this product.
Power
Do not apply power to the fixture until power source is verified. Do not attempt to use this fixture if it appears damaged. For protection against electric shock, fixture must be connected to suitable earth ground. Make sure fixture is disconnected from power mains before any service.
This fixture automatically adjusts to mains voltage and frequency 100-265vAC 50/60Hz. The listed power rating is its average wattage under normal conditions. All fixtures must be powered directly from a switched circuit. This fixture cannot be run on a rheostat or dimmer circuit even if
5
Loading...
+ 11 hidden pages