Technibel TAF 208 L, K 60 C 852 Z, K 60 C 862 Z, TAF 308 L, TAF 408 L Installation Instructions Manual

...
1
GB
F
I
E
D
Novembre 2008 10 11 524 - F.GB.I.E.D - 00
ELECTRIC HEATER
RISCALDAMENTO ELETTRICO
CALEFACCIÓN ELÉCTRICA
ELEKTRO HEIZUNG
Pour / For / Per / Para / Für
TAF 208 L / 308 L TAF 408 L
TAF 208 L / 308 L TAF 408 L
KITS
2kW : K 60 C 852 Z
K 60 C 862 Z
3kW : K 60 C 853 Z
K 60 C 863 Z
NOTICE D’INSTALLATION
INSTALLATION INSTRUCTIONS
MANUALE DI INSTALLAZIONE
MANUAL DE INSTALACIÓN
AUFSTELLUNGSHANDBUCH
CLIMATISEUR INDIVIDUEL
ROOM AIR CONDITIONER
CLIMATIZZATORE INDIVIDUALE
ACONDICIONADOR INDIVIDUAL DE AIRE
KLIMAGERÄT
2
GB
F
E
D
I
1 - Introduction ............................................................................................................. 2
2 - How to fix the electric heater................................................................................... 3
3 - Fastening the contactor - Connection ..................................................................... 3
4 - Electrical diagrams.................................................................................................. 4
1- GENERAL
• The equipment must be installed, started-up and maintained by authorised and qualified personnel, in accordance with local rules and professional standards.
1.1 - GENERAL CONDITIONS OF DELIVERY
• Generally speaking, the equipment is shipped at the risk and peril of the addressee.
• If the addressee should not any damage caused in transit, he should immediately notify the carrier in writing.
1.2 - VOLTAGE
• Prior to any operation, check that the voltage specified nameplate agrees with the supply voltage..
1.3 - USE OF EQUIPMENT
• Electric heating kit intended for assembly in TECHNIBEL air conditioners of the type indicated in this manual.
1.4 - PRESENTATION
• The heating kit is composed of:
- 1 heating element assembly equipped with a safety thermostat with automatic reset B5 and a manual reset B,
- 1 power supply contactor K5.
IMPORTANT
Before doing any work on the installation, make sure it is switched off and put out of bounds.
• Ensure that the electric wires are securely fastened to the terminals. Poor connection can generate heat and thus cause fires.
• Ensure that the electric wires are well insulated in relation to any sheet metal or other metal part that might damage them.
• The air conditioner must not be installed near inflammable materials.
• Refer to the appliance’s installation manual.
1.5 - PRECAUTIONS
SUMMARY
CAUTION:
If the manual reset safety thermostat is tripped, the device must be checked by a technician. Resetting this safety thermostat is done via the red push-button (accessible after having switched off the device and dismantled the blowing grid).
3
GB
F
I
E
D
2 - HOW TO FIX THE ELECTRIC HEATER
3 - FASTENING THE POWER SUPPLY CONTACTOR - CONNECTION
See position here below.
• Fasten contactor K5 above the terminal strip.
Connect the wires to the appliance’s terminal strip according to the wiring diagrams further on.
IMPORTANT :
The standard components of the appliances (TAF) include an adhesive aluminium strip placed inside the interchangeable front panel to protect the insulation from heat.
In the case of appliances not equipped with this aluminium strip (old appliances), apply the aluminium supplied with the kit as shown below. Refer to disassembly in the appliance’s installation manual.
Remove the casing (refer to the appliance’s installation manual).
• Position the two fastening screws.
• Position the heating kit on the exchanger and tighten the screws.
• Feed the wires through the hole at the top of the right mounting of the exchanger (make a notch in the insulation).
Ceiling mounting: use the 2 blocage clips.
Contactor K5
Aluminium strip (inside)
Interchangeable panel
Fixing screws
Passage of wires
Blocage clips
4
GB
F
E
D
I
K 60 C 853 Z - K 60 C 863 Z - 3 kW
230/1/50-60 - 400/3N/50-60
10 05 608 - 00
K 60 C 852 Z - K60 C 862 Z - 2 kW
230/1/50-60
10 05 607 - 00
4 - WIRING DIAGRAMS
B5 - Thermal safety with automatic reset. B6 - Thermal safety with manual reset. K5 - Heating contactor. R5 - Electric heater. R6 - Electric heater. R7 - Electric heater.
SYMBOLS OF THE COMPONENTS
COLOURS OF THE WIRES
N Black R Red J/V Yellow / Green
B Blue G Grey M Brown
K5
31
42
A2
A1
N
B
R
N6
M
G
B
2
1
B6
T
N5
M6M5
R6
R5
2
1
B5
T
K5
M
A2
A1
1
3
R
G
B
2
1
B6
T
2
1
B5
T
K5
M
R7
R5
2
BB
B
6
5
K5
5
6
3
4
1
2
4
R6
K5
56341
2
1
ELECTRICAL CONNECTIONS
3 kW - Single phase 230 V
2 kW - Single phase 230 V
Control
Kit
chauffage
N
U1
B
N1
JV
R
6
Electric heating
kit
N
U1
B
N1
JV
R
6
K5
Electric heating
kit
Control
5
GB
F
I
E
D
22
GB
F
E
D
I
23
GB
F
I
E
D
24
GB
F
E
D
I
Par souci d'amélioration constante, nos produits peuvent être modifiés sans préavis.
In order to carry on a constant improvement, our products can be modified without prior notice.
Per garantire un costante miglioramento dei nostri prodotti, ci riserviamo di modificarli senza preavviso.
En el interés de mejoras constantes, nuestros productos pueden modificarse sin aviso prévio.
Unsere Produkte werden laufend verbessert und können ohne Vorankündigung abgeändert Werden.
R.D. 28 Reyrieux BP 131 01601 Trévoux CEDEX France Tél. 04 74 00 92 92 - Fax 04 74 00 42 00
Tél. 33 4 74 00 92 92 - Fax 33 4 74 00 42 00
R.C.S. Bourg-en-Bresse B 759 200 728