Introduction
This manual provides introductions to users about how to operate the device correctly. The content includes introduction to product installation, product characteristics and product settings, etc.
It is highly suggested users to go through this document before actually operating the device.
If you need help, please contact us at:
Technalogix Ltd. #4, 8021 Edgar Industrial Place Red Deer, Alberta, Canada T4P 3R3 Phone: 403.347.5400 Fax: 403.347.7444 URL: www.technalogix.ca Email: techsupport@technalogix.ca
sales@technalogix.ca bob@technalogix.ca romeo@technalogix.ca
2
Contents
1. About this product…………………………………………………………………...…………........4
1.1 Introduction……………………………………………………………………..........…….……..4
1.2 Safety…………………………………………………………………………………………….….4
1.3 Architecture…………………………………………………………………………………..……5
1.4 Methods of Operations…………………………………………………………………….….....6
1.4.1 Operations through WEB GUI…………………………………………………..……6
1.4.2 Operations through Front Panel………………………………….…..………..…....7
1.5 Technical Specifications………………….…………………………………………….…….....7
1.5.1 Physical Specifications…….……………………………………………..………………….…..….7
1.5.2 Performance and Capacity………………….…………………………….....................................7
1.5.3 Interfaces and Protocols…………………………………………………......................................8
2. Installation………………………………………………………………………………………….…...9
2.1 Installation Procedures………………………………………………………………………………...9
2.2 Preparation before Installation…………………………………………………………………...…...9
2.3 Check Package and Accessories……………………...……………………………………….…...10
2.4 Equipment Wiring and Connections………………...…………………………………………......10
2.4.1 Connection Setup for RF Signal Input…………………………...…………………………........11
2.4.2 Connection Setup for ASI Signal Input……………………………...……………………….......11
2.4.3 Connection Setup for IP Signal Input…………………………….................................……….11
3. Operation Guide…………………………..……………………………………………...…………....12
3.1 Operation Overview………………..……………………………………………………………….....12
3.2 Powering Up and Initialization…………...………………………………………………………….12
3.3 Front Panel Operation…………………………..………………………………………………..……12
3.3.1 Front Panel Menu Structure…….……………………...……………………………………..…...13
3.3.2 Front Panel Operation Guide………………………………...………………………………..…..15
3.4 WEB GUI Operation……………………………..………………………………………………..……16
3.4.1 Web Management Connecting………………………………………………………………..……16
3.4.2 Parameters Configurations………………………...………………………………………..……..17
3.4.2.2 Status Page………………………………………………………………………………………….19
3.4.2.3 Program Mux Settings…………………………………………………………………………….20
3.4.2.4 Inputs………………………………………………..…………………………...………………….24
3.4.2.5 Outputs…………………………………….……………………...………………………………..28
3.4.2.5 Failover Slate…………………………..………………………..........................................…....31
3.4.2.6 Conditional Access…………………………………………………………………………...…...32
3.4.2.7 System……………………………………………………………………………………………….34
3.5 Preparation before Official Operation……………………………………..………………...…...36
3.5.1 Clear all useless data……………………………………….……….……………………………...37
3.5.2 Configure the equipment with working data…………………………………………….……..37
3.5.3 Full checking before implementation…………………..……………......................................37
4. FAQ…………………………………………………………………………………..……………….....38
5. Terminology……………………………………………………………………..………………….….40
6. Specifications……………………………………………………………………………………….…41
3
1 About This Product
1.1 INTRODUCTION
This product is a new generation Transmodulator/Processor to support the growing demands for multi-format, multi-standard video delivery and distribution. It can receive digital signals from several inputs i.e. 8-VSB, (DVB-S/S2, DVB-C (optional), DVB-T/T2/ISDB-T (optional), ASI, and others), It can also decrypt and process/select programs to various outputs including CVBS, HDMI, SD/HD SDI, ASI, Output Modulator, etc. It supports multi-channel descrambling, multiplexing, external table/data insertion, transcoding and transmodulating. It also supports video decoding with two audio channels. With remote web-based management interface, it is ideal to support advanced applications such as content distribution, real-time signal conversion and transmission.
1.2 SAFETY
To avoid electric-shock hazards, do not open the unit; refer service to qualified personnel only. Do not expose the device in the sunlight, and keep it away from a heat source. Do not block ventilation holes of the device so that air can circulate freely. Switch the device off whenever it remains out of service for an extended period. Be sure to turn the device off and disconnect the AC power cord before cleaning the unit
surface.
The apparatus shall be connected the mains socket outlet with a protective grounded
connection.
This product has gone through regulated EMC test and meets with EMC safety requirement.
( Such tests are conducted in a controlled EMC environment. A controlled EMC environment exists in a building where the installation has been designed
having special regards to EMC, and where technical personnel are present with experience of EMC technology.)
4
1.3 ARCHITECTURE The equipment of this section is shown in the schematic diagram. It is subject to change due to improvements or advancements in the product.
Changes may be made without advanced notice. Front Panel
1 2 3 4 5 6 7
PIC-1.3-1
1. Power status indicator: This LED light is turned on when the unit is power on.
2. (Signal) Lock status indicator: This LED light is turned on when a channel is locked.
Otherwise there is no channel locked.
3. Alarm status indicator: This LED flickers when there is something abnormal. For example, the
strength of the input signal is weak.
4. Display screen: This LCD screen can show the program and configuration information.
5. KEY PADS:
Up/Down/Left/Right arrow keys: To change channels, to adjust volumes and configure
the unit.
6. Menu: To enter the menu and the quit function of the sub menus.
7. OK: To confirm the operation in the setup.
Rear Panel
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18 19 20 21
5
PIC-1.3-2
1
RF LOOP IN
2
RF OUT
3
GPI/LS DATA Out
4
CVBS Out
5
R-AUDIO 1
6
R-AUDIO 2
7
ASI OUT 2
8
ASI IN 2
9
RF IN
10
BALANCED AUDIO OUT
11
HDMI
12
SDI OUT
13
L-AUDIO 1
14
L-AUDIO 2
15
ASI OUT 1
16
ASI IN 1
17
MANAGEMENT
18
TS/IP
19
TS/IP (Redundant)
20
POWER CORD IN
21
POWER SWITCH
Redundant POWER (Optional)
Functions
Description
Related Items
Parameters Setting
WEB GUI allows users to conduct operating parameter configuration, modification and setup.
Signal receive setup CI setup Decoder setup
Status Monitoring
Support real-time monitoring on running status of input signal, CI descrambling, etc.
RF signal strength indication CI slot/CAM information HW/SW version information
Upgrade
Support unit upgrade through WEB GUI
NOTE: Both power cords MUST be connected (An alarm will sound if only one power cord is connected)
1.4 METHODS OF OPERATION
1.4.1 Operation through WEB UI
Operate the unit remotely through WEB GUI. The WEB GUI operation supports:
6
1.4.2 Operation through Front Panel Operation
Functions
Description
Related Items
Parameters Setting
Allows users to conduct operations of parameters configuration, modification and setup.
Signal receive setup CI setup Decoder setup
Status Monitoring
Support real-time monitoring on running status of input signal, CI descrambling, etc.
RF signal strength indication CI slot/CAM information HW/SW version information
Items
Index
Power
AC100~240VAC
Max. Power Consumption
Approx 40W
Size
1RU
Dimension
480mm (W) × 44mm (H) × 440mm (D)
Net Weight
Approx 3.8Kg
Gross Weight
Approx 5Kg
Items
Index
ASI Max. Input Bitrate
100Mbps
ASI Max. Output Bitrate
100Mbps
Decoder Max. Resolution
1920 X 1080i
CI Max. Output Bitrate
100Mbps
Operation through front panel control buttons; users may configure all the parameters according to the following:
1.5 TECHNICAL SPECIFICATIONS
1.5.1 Physical Specifications
1.5.2 Performance and Capacity
7
Inputs
IP input
ASI input
Interface: 1 x 1000 Mbps
Interface: 2 ASI inputs, 75Ω
IP Encapsulation: UDP/RTP
MPEG Format: 188/204 Bytes per TS
MPEG TS: MPTS and SPTS
Max bit rate: 100 Mbps
Input processing: Up to 2 channels, max at 72 Mbps per channel.
Support input redundancy.
DVB-T2 (Optional)
DVB-T (Optional)
Constellation: 16/32/64/128/256 QAM
Constellation: QPSK/16/64QAM
Bandwidth: 1.7Mhz, 5Mhz, 6Mhz, 7Mhz, 8Mhz, 10Mhz
Bandwidth: 6/7/8Mhz
Input frequency: 48~862MHz
Input frequency: 48~862MHz
Max. bitrate: 50Mbps
Max. bitrate: 31.67Mbps
Transmission mode: 1K, 2K, 4K, 8K, 16K, 32K
Transmission mode: 2K, 8K
DVB-S/S2
DVB-C (Optional)
Input Frequency: 950~2150 MHz
Frequency: 48~862 MHz
Constellation: QPSK, 8 PSK
Constellation: 16/32/64/128/256 QAM
ISDB-T/Tb (Optional)
ATSC (Optional)
Constellation: QPSK/16/64QAM DQPSK
Constellation: 8VSB
Bandwidth: 1.7Mhz, 5Mhz, 6Mhz, 7Mhz, 8Mhz, 10Mhz
Bandwidth: 6Mhz
Input frequency: 48~862MHz
Input frequency: 57~803MHz (fixed)
Transmission mode: 1K, 2K, 4K, 8K, 16K, 32K
Max bitrate: 19.39Mbps
Outputs
IP output
ASI output
Interface: RJ45
Interface: 2 ASI outputs, 75Ω
IP Encapsulation: UDP/RTP
MPEG Format: 188/204 Bytes per TS
MPEG TS: MPTS and SPTS
Max bit rate: 100 Mbps
Output processing: Up to 2 channels, max at 72 Mbps per channel, support TS/IP redundancy.
1.5.3 Interfaces and Protocols
The physical connector design is subject to change without advanced notice
(to either the connector type or specific connector location) according to user’s
specific order, performance improvement, or for better user experience.
8
2 Installation
Preparation
Check Package
Setup Connection
(signals, wiring)
Parameters
Configuration
System Debug
Finish
2.1 INSTALLATION PROCEDURE
2.2 PREPARATION BEFORE INSTALLATION
Before installation, the installation personnel should read through and confirm the following:
Thoroughly read this user manual. Has complete knowledge of digital television systems. Has defined the sources, rack allocation, set-up plan, and system wiring. Knows how to operate this unit and familiar with the parameters of configuration. Go through related engineering design documents about the system.
9
2.3 CHECK PACKAGE AND ACCESSORIES
The unit packaging includes the following accessories:
Base Unit x1 Power cord x2 Ground Wire x1 BNC cord x1 BNC-RCA cord x2 User Guide Disc x1
2.4 EQUIPMENT WIRING AND CONNECTION
To avoid electric shock and damage to the equipment, before setting
up the wiring connection, please power off the equipment and all other connected external devices. The equipment and external devices must be grounded. Powering on the equipment only after all the wiring connection is completed.
Connection Diagram
PIC-2.4-1
10
In actual application, not all connection interfaces need to be connected with signal/external devices. Please connect according to actual application purpose.
To ensure a smooth communication between the management PC and
the TP400D, please try to connect the UNIT management port to a switch without large data processing.
2.4.1 Connection Setup for RF Signal Input
Connect signal to tuner input (either RF1 or RF2 input) with a RF cable.
Connect the TP400D “Management” port to a switch, set up a management network
with the management PC.
Connect the TP400D with the monitor via HDMI, SDI or CVBS ports.
2.4.2 Connection Setup for ASI signal input
Connect ASI signal to TP400D “ASI IN” port with a BNC cable.
Connect the TP400D “Management” port to a switch, set up a management network
with the management PC.
Connect the TP400D with the monitor via HDMI, SDI or CVBS ports.
2.4.3 Connection Setup for IP signal input
Connect IP signal to TP400D “TS/IP” port with a twisted cable.
Connect the TP400D “Management” port to a switch, set up a management network
with the management PC.
Connect the TP400D with the monitor via HDMI, SDI or CVBS ports.
11
3 Operation Guide
TP400D Transmodulator/Processor IP: 192.168.001.098
TP400D Transmodulator/Processor Setting System…
3.1. OPERATION OVERVIEW
This chapter provides information on how to operate the TP400D through front panel and WEB GUI. User can select the appropriate operation method to set up the unit.
3.2. POWERING UP AND INITIALIZATION
Switch on the equipment through the rear power switch, and the unit is powered up and starts the initialization process. The LCD screen is lighted up, and display information is as follows:
The initialization takes about 20 seconds to complete, and then the unit shows the IP address information is as follows:
Before powering-up the device, make sure that all cabling is
correctly connected (refer to chapter 3.4 of this manual). Make sure the device is correctly connected to the power inlet and is grounded.
If the unit fails to initialize and hangs at the “booting” stage, switching off the device and then powering up again may help. If the device still fails to initialize, please contact your service representative for help.
3.3. FRONT PANEL OPERATION
Ways of operation: use the 6 navigation keys on front panel: Up / Down / Left / Right / Menu / Ok to configure the TP400D parameters. The configuration and settings are displayed through front panel LCD.
12
3.3.1 Front Panel Menu Structure
1st Layer
2nd Layer
3rd Layer
Status
Input Tuner 1/2
Lock Status
FEC
PER
Frequency Offset
Frequency Tune
TS Rate
RF Level
C/N
BER
Input ASI 1/2
Lock Status
TS Rate
Input IP 1/2
Lock Status
TS Rate
Decoder
TS Rate
PCR PID
Audio PID
Video PID
PMT PID
Program No.
CI
CI Slot 1/2
Output ASI
ASI 1 TS Rate
ASI 2 TS Rate
Output IP
IP 1 TS Rate
IP 2 TS Rate
Inputs
Tuner 1/2
Tuner 1/2 Params
Enable
TS Standard
LNB Frequency
Satellite Frequency
Symbol Rate
Front Panel Menu Structure
13
LNB Power Supply
LNB 22KHz
Scan TS
ASI 1/2
Enable
TS Standard
Scan TS
IP
Local Setting
TSIP Channel 1/2
Outputs
Decoder
Playing Program
TS Source
Program List
Video
Video Standard
Aspect Ratio
Video Format
Audio
Audio Volume
Audio Mixer
Audio 1/2 Language
Subtitle
Subtitle Standard
Teletext
Teletext Standard
ASI
ASI 1/2 TS Source
Tuner 1/2
Mux 1/2
ASI 1/2
IP
TSIP Channel 1/2
Enable
TS Source
Dest IP Address
Dest Port
Protocol
Time to Live
TS Packet Number
Enable Dest MAC
Dest MAC
CA
Common Interface
CI 1/2
TS Source
Descrambling
CAM Max Bitrate
14
BISS Setting
BISS Setup
BISS Mode
BISS-1 Setup
BISS-E Setup
System
Local Setup
Local IP Address
Local Network Mask
Local Gateway
MAC Address
Version
Factory Setting
Reboot
3.3.2 Front Panel Operation Guide
Enter “Menu”:
o Press “MENU” button to enter main menu.
Exit Menu/Back to parent Menu
o Upon completion of configuration settings, press “MENU” button until you
go back to the Parent Menu.
Enter Sub-Menu
o Press MENU button to enter main menu. o Select a sub-menu by pressing arrow UP and arrow DOWN button. o Press OK button on the selected sub-menu.
To change parameter
o Step 1: Enter main menu by pressing MENU button. o Step 2: Scroll sub-menu by pressing arrow UP and arrow DOWN button,
and press OK button to change the selected sub-menu.
o Step 3: To change parameter settings, press arrow RIGHT and arrow
LEFT button to move the cursor in which change must be made.
o Press arrow UP button and arrow DOWN to input / select an appropriate
setting, then press OK button to save.
15
3.4. WEB UI OPERATION (RECOMMENDED)
Accessing the equipment via Web can be very convenient for remote configuration of the equipment. Relative to the front panel settings WEB operation can provide a friendlier man-machine interface, and with less limits in space. WEB Management is recommended.
3.4.1 WEB Management Connecting
Connection Instruction:
PIC-3.4-1
1. Connect the “MANAGEMENT” port of the UNIT to a network switch and connect the management PC/server to the same network switch.
2. The UNIT default IP address is 192.168.1.98. It is important to set the IP address of the UNIT and the monitoring severs in the same section to ensure a smoothly connection between them.
3. Open a web browser (e.g. Mozilla, internet explorer, safari and etc.), enter the equipment’s IP address in format: http://xxx.xxx.xxx.xxx (xxx.xxx.xxx.xxx refers to UNIT’s IP address) and press ENTER button to confirm. The browser will attempt to connect to the device. If succeed, a login page will appear. (see PIC-
3.4.2)
Note: Through WEB browser, you may manage several pieces of the TP400D at the same time, as long as those equipments are connected to the server via Network Switch. Make sure that the equipment and
server’s IP address should be in the same section. Nevertheless, Subnet
Mask and Gateway should be the same for both the server and the equipment.
16
PIC-3.4-2
Menu Area
Parameters Area
To login, you need to enter the default username “admin” and password
admin”. Then click “Submit”.
If the user name and password is correct, it will redirect to the main page.
3.4.2 Parameters Configuration
3.4.2.1 Main Page
The main page can be divided into two functional areas:
Menu Area: you can switch between the menus to display the corresponding
PIC-3.4-3
17
parameter setting and monitoring pages.
Parameters Area: displays the corresponding parameters pages according to the
menu selection.
The WEB management page allows you to monitor and/or configure: Status, Receiver, Program Setup, CA, Local Setup, Alarms Setup, User Management, Preset, Upgrade, Log and etc.
Menu Area:
This area shows the main menu items of the machine, you can click the item you want to configure or monitor, then the detailed information will appear in the right area.
Parameters Area:
This section is the main section for monitoring and configuration of the machine. It shows the detailed information of the machine of each menu. Its detailed function will be introduced in to following chapters.
PIC-3.4-4
18
3.4.2.2 Status Page
This page allows you to monitor the status of input and output signal, and check the information of CI cards.
PIC-3.4-5
Input status (tuner/ ASI/ IP): It shows the main information of input streams,
such as lock status, RF BER, RF Level, Total RF Rate , ASI total rate, ASI effective rate etc.
Decoder status: Here you can see the decoder information: video PID, Audio
PID and PMT PID.
CI status: You are able to monitor the status of CI cards.  Output status (ASI/ IP): You can check the output TS rate and the TS status.
19
3.4.2.3 Programs Mux Setting s
1
2
3
If you want to configure the parameters of multiplexed programs, just click the “programs
Mux Setting” button on the left bar. Then you will turn to the programs information
interface, where you are able to check and modify the parameters of programs.
PIC-3.4-6
Input Program Configuration: The “Input Program Configuration” is on the left
side of the window. It displays the entire information of the received input streams
Output Program Configuration: In the “Output Program Configuration” window,
it shows the ports which can be set to transmit output stream. The programs set to be outputted are shown in the submenu of each port.
Operation Buttons: This area contains three functional buttons: Refresh, Apply and Save.
Apply: to make the programs configuration take effect. Once the device is powered off, the programs configuration will lose and device will be restored to the last saved configuration. Save: to make the programs configuration take effect as well as save the configuration information. Refresh: by clicking this button to refresh the programs information.
20
How to dispose the Inputs:
To get the input programs, you should choose the sub-menu in the Inputs menu on the left. Then it will turn to the corresponding page where you are able to set the receiving parameters to lock the signals. (Referring to chapter 3.4.2.4) If the signal is locked then programs information will be listed on the frame as the following picture shows.
PIC-3.4-7
How to configure the Outputs (Mux1 and Mux2):
Firstly, select the port which you want to transmit the output stream. Right click the TS in that port and a pop-up menu will appear. Click “ADD TS” item and you will get the input box.
PIC-3.4-8
Secondly, Input the “Original Network ID” and “TS ID” for the channel, and click the “OK”
button. Then the “Original Network ID” and “TS ID” will be assigned to the selected
output TS (channel).
21
PIC-3.4-9
Also, by clicking the edit icon, you are able to modify the TS name, network ID and TS ID. To delete existing TS, you can click the minus icon as follows:
PIC-3.4-10
And it is able to delete the TS or programs in the Mux menu by clicking the cross icon at the rear of the program or TS. Shown as the following picture:
PIC-3.4-11
22
After completing the configuration, you should click “Apply” button to enter it or
“Save” button to enter and save it.
The outputs ( Mux1 and Mux2) will be available for ASI/ IP inputs after
configuration.
23
3.4.2.4 Inputs
Area 3
Area 1
Area 2
DVB-S/S2
PIC-3.4-12
Area 1/ Area 2: In this section, you are able to set the dual RF receiver parameters
including the Satellite Frequency, Symbol Rate, LNB Frequency, and LNB Voltage
(Polarization) with accurate values. Then you can press the “Submit” button to save your
settings or click “Refresh” button to refresh the screen.
Area 3: When the signal is locked, it is able to get the program list in by clicking the
ScanTS (Tuner1/Tuner2).
Enable: Enable or disable corresponding input channel  Satellite Frequency (MHz): set the satellite down conversion
frequency. You can get this parameter from the satellite program provider.
Symbol Rate (KBaud): set the correct symbol rate. You can get this
parameter from the satellite program provider.
LNB Frequency: this is the LNB’s local oscillation (LO) frequency,
every LNB have one or two oscillation frequencies which can be obtained from the LNB provider, or you can check on the LNB label. The value is between 5000 and 6000.
LNB Power Supply: LNB voltage is the power that supply to the LNB
in order to receive satellite signal with different polarization. Generally
24
18V is for Horizontal while 13V is for Vertical.
LNB 22 KHz: Generally this is used to control 22KHz switch, typically
used for LNB with double L.O. in Ku band. “ON” is for high L.O and
“OFF” is for low L.O.
TS Standard: there are two options for TS standards: DVB and ATSC.
Depending on the input module used, sometimes the parameters
may change; it is advisable to check through www.lyngsat.com for the updated satellite parameters if utilizing a satellite delivered program source.
DVB-T/T2 (Optional)
If the tuner is for DVB-T/T2 or 8VSB receive, it will change to the above (or similar) interface when clicking the inputs menu. This page is to configure the parameters of DVB-T/T2 receive. There are three parameters as following:
Mode: to set DVB-T or DVB-T2 receiving.  Frequency: to input the frequency that the receiver is appointed to
receiving..
Bandwidth: There are three options: 6M/7M/8M. Set the corresponding
parameter according to the operator requirement.
DVB-C (Optional)
Regarding DVB-C parameters, user only needs to input the frequency, symbol rate and QAM mode to scan and receive the input signal.
ASI
25
PIC-3.4-13
Area 1
Area 2
Area 3
Area 1
Area 2
This page shows the Input ASI information. There are two channels available to receive ASI streams: ASI1 and ASI2. Area1: set the ASI parameters, include Enable and TS Standard. Enable: enable / disable the ASI channel to receive input stream. TS Standard: select the correct TS standard: DVB or ATSC Area2: displays the programs list of the input stream. You can get the programs list by clicking the ScanTS (ASI1) and ScanTS (ASI2).
IP
From this page, you can setup the device’s local IP parameters (Area1) as well as the
TSIP ports’ output parameters (Area2 and Area3). There are two TSIP channels
available for receiving IP streams.
PIC-3.4-14
26
Area1: Set the devices’ local IP parameters to enable it to be connected into the
PIC-3.4-15
network:
IP Address: Local IP setting for connecting to the server. This IP and the
management server’s IP should be in the same section.
SubnetMask: Network Mask setting for connecting to the server. It should
be the same as management server: 255.255.255.0
GateWay: Gateway setting for connecting to the server. It should be the
same as the management server.
IGMP Version: The IP transmission supports IGMP V2 and IGMP V3, you
can choose the one you need manually. Area2: The parameter of channel 1 and channel 2. After finishing the configuration, click “Submit” to make it into effect.
Enable: Enable or disable corresponding output channel  Source IP Address: it is the IP address of the source IP streams. Source Port: It is the port of source IP streams.  Protocol: You can choose UDP or RTP for multicast/unicast.
Area3: To get the program list of IP input by clicking ScanTS (Tuner1) / ScanTS (Tuner2).
Backup Setting
In the Backup Setting page, user can set redundant sources for the main input signal. The main and backup input source can be selected from Tuner, ASI or IP. In case there is any error for the main input signal, the UNIT will automatically switch the input from main to the backup, to ensure the UNIT output non-stop.
27
3.4.2.5 Outputs
Decoder
In this page, user can view and configure the decoding output program parameters, including: Program, CAM, Video, Audio, Subtitle and Teletext.
PIC-3.4-16
The device can decode the input streams and output by CVBS or HDMI.
For each time only one program can be decoded and output.
The parameters set in “Program Setup” interface work for all selected
program.
Playing Programs: This interface, all the programs received will be listed in “TS Source” region. By changing the program’s operation, you can determine which program to decode.
PIC-3.4-17
If the input signal is not locked and searched, the “program” section shows empty. User
cannot do any setup until the unit is locked.
28
Video:
Here, you can configure the video parameter, as follows:
PIC-3.4-18
o Video Standard: in this item, you can select video standard, available
options include: Automatic, SECAM, NTSC, PAL-N, PAL-M and PAL.
o Aspect Ratio Conversion: you can setup the aspect ratio for the
decoded programs, available options include: Pillarbox (Side Bars), 16:9 Pan and Scan, 4:3 LetterBox, and 4:3 Pan and Scan.
o Video Output Resolution, you can select the video format (resolution)
for the decoded program, available options include: Auto / 480i / 576i / 720p50 / 720p59 / 720p60 / 1080i50 / 1080i59 /
1080i60.
The decoder output video resolution should meet with the monitor
resolution setting.
Audio: In this section, you can configure the information of Audio, as follows:
PIC-3.4-19
o Audio Volume: Set the output audio level from -63 to max. 0 in dB. o Mixer: set the format of audio, including Stereo, Left, Right, Mono and
Dual.
o Audio1/2 Preferred Language: Select audio language if there are
multiple audios contained in the signal.
Subtitle:
29
o Subtitle Standard: You can set the subtitle to be EBU or DVB.
o Subtitle Language: Here you can set the language of subtitle from the
Teletext
o Teletext Standard: choose disable to turn off the Teletext or enable to
o Teletext Language: You can set the Teletext language here.
PIC-3.4-20
EBU: The European Broadcasting Union is the world's foremost alliance of public service media entities DVB: It means Digital Video Broadcasting, a set of standards relating to digital television
existing selections.
PIC-3.4-21
turn on the Teletext.
ASI In this page you are able to choose the input signal from Tuner, ASI, IP or Mux as signal source for the ASI output. After configuration you need to click submit button to make it taking effect immediately.
PIC-3.4-22
Only the Enabled Input will be listed on the TS source list.
IP In this page, you can set up the parameter of IP output. There are two channels for output and you can set both of them.
30
PIC-3.4-23
Enable: Enable or disable corresponding output channel  TS Source: to choose the input signal as IP output.  Dest IP Address: The IP address for the multicast/unicast.  Dest Port: The port of the multicast/unicast, it must stay same with the
value of the dest device.
Protocol: You can choose UDP OR RTP for multicast/unicast.  Time to Live: Range is 1-255. (Num 8 is recommended)
Enable Dest MAC: You can decide whether to set the MAC of
destination device.
Failover Slate
In this page, user can view and configure the output in case that the input is lost. The user has the choice to output either a slate (still Picture) or black.
PIC-3.4-24
31
Sample of the Slate/Still image:
Area 1
Area 3
Area 2
PIC-3.4-25
3.4.2.6 Conditional Access (Optional, Consult Factory)
In this page, user can manage the configuration setting related to the device decryption and descrambling capability.
PIC-3.4-26
Area1: this area is for CAM (Conditional Access Module) bit-rate setting, where you can
set the maximum bit rate according to the CAM inserted.
32
Area2: This area is for the BISS setting.
BISS (Basic Interoperable Scrambling System): is a satellite signal
scrambling system developed by the European Broadcasting Union and a consortium of hardware manufacturers. There are two types:
o BISS-1, transmission are protected by a 12 digit hexadecimal “session
key” that is agreed by the transmitting and receiving parties prior to
transmission. The key is entered into both the encoder and decoder, this key then forms part of the encryption of the digital TV signal and any receiver with BISS-support with correct key will decrypt the signal.
o BISS-E (E for encrypted), is a variation where the decoder has stored
one secret BISS-key entered by for example a rights holder. This is unknown to the user of the decoder. The user is then sent a 16-digit
hexadecimal code, which is entered as a “session key”. This session key
is then mathematically combined internally to calculate a BISS-1 key that can decrypt the signal.
o BISS-E ID, an identification ID given prior to transmission and reception.
Area3: In this area, it is able to choose the programs that need to be descrambled and
set the CAM info. All the received signals will be listed in the “TS Source” menu. Then
you can choose the programs that you want to descramble on the program list and click the “Submit” button to make it into effect.
TS Source: to choose the input signal as IP output.
Usually a standard CAM can support a certain data processing unless it has instruction for higher bit rate support. Selecting a wrong CAM output bit rate will cause video mosaic issue because the actual processed data exceeds the CAM Max handling capability.
3.4.2.7 System
LocalSetup
PIC-3.4-27
33
In this page, you are able to configure the following parameters:
IP Address: Local IP setting for connecting to the server. This IP and the
management server’s IP should be in the same section.
Network Mask: Network Mask setting for connecting to the server. It
should be the same as management server: 255.255.255.0
Gateway: Gateway setting for connecting to the server. It should be the
same as the management server.
Trap IP Address: This IP should be the same as the monitoring server’s
IP. After correct setup, the UNIT will pass the alarming and running information to the monitoring server.
Language: to configure the UI displaying language.
Import/Export
This menu is for user to import/export the machine configuration file.
GPI Alarms
PIC-3.4-28
In this section, user can set the alarm information to monitor the device and signal. After
setting the “Alarm Mask” on, the “GPI” item will be available to be set as On or Off. If the
GPI is set to on, when there are LNB Disconnect, Signal unlocked or CAM error, the alarm information will be sent out via GPI.
34
User Management
PIC-3.4-29
Change Password:
When the user puts a check on this button, user can change the password
with a new one.  Change Username: Here, you can change the existing username to a new one.  Create a User:
The device allows you to add up to 10 new users to operate the device. You
can set the new username and password after selecting “Create a User”
button. Delete a User:
By selecting this section, you are able to delete the user account from the
existing account. If the user account is deleted, the user will have no rights to
access the device.
License
This menu is for module licensing control on the machine. User can purchase upgrade packages from EMCEE to extend the machine I/O function and capability. User must check with the factory first to determine whether the unit supports license upgrade or not.
PIC-3.4-30
35
Upgrade
PIC-3.4-31
Click Browse button, then user can select the upgrade file, and click “Upgrade” button to
start the upgrade. If succeed, restart the device and it will load the new version
Log
In this page user can export and review the log of the machine.
LogOut
PIC-3.4-32
User can logout of the management system by clicking this button.
3.5. PREPARATION BEFORE OFFICIAL OPERATION
This section advises what needs to be performed on the UNIT before you formally start on-line operation. It includes but not limited to the following:
Clear test data Configure the equipment with working data. Routing inspection.
3.5.1 Clear all useless data
To do a factory default setting on the device in order to clean up all test data generated in the process of debugging and testing.
3.5.2 Configure the equipment with working data
According to the formal system plan, configure the UNIT for signal input, descramble function, and decoding output.
36
3.5.3 Full check before implementation
After completion of the test and configuration, users are recommended to give the equipment a final full-scale check to ensure everything is on track for working with long-
term stability. It shall contain (but not limited to) the following items
Check the strength and quality of all input signals.
Check if there are any alarm lights on front panel LED indicator.
Check whether the cable connections are in good condition which are connected to each external device.
37
4 FAQ/Trouble Shooting
Problem
Possible Reasons
What to do
The LCD display on the front panel does not light up.
No power.
Check whether the power cord is plugged into the power socket.
No Video output
Parameters are not properly configured.
Check the parameters configuration
No signal
Check the source and other factors that affect the signal reception.
The TV set is not tuned to the right TV mode.
Set TV in right mode, e.g. (Set TV to CVBS display mode for CVBS decoding input from UNIT, and HDMI mode for UNIT HDMI input, etc.)
No or bad signal. No cable connection or
the program does not exist in current satellite.
Check the cable connections, LNB and other equipment connected between the LNB and the STB, and /or adjust the dish.
The satellite dish is not properly oriented to the satellite.
Align the dish. Check the signal level in the UNIT menu.
Bad picture / Blocking error. The satellite dish is not
properly oriented to the satellite.
Align the dish.
Signal is too strong.
Connect a signal attenuator to the LNB input.
38
Problem
Possible Reasons
What to do
Signal is too weak.
Change to a larger dish.
LNB noise figure is too high.
Change a LNB with lower noise figure.
The LNB is defective
Change a LNB.
Signal is good. But No picture and no audio on decoding output
The picture and audio are scrambled.
Insert correct CAM and authorized smart card to descramble the programs.
Cannot have access to the UNIT through WEB UI
IP setting
Check whether the management PC IP and the UNIT IP have been set to be in same section.
Network cable problem
Make sure the cable is good one and connect well to the UNIT management port.
Cannot Decrypt Programs.
Haven’t selected
decrypted programs or select incorrectly.
Select decrypted programs to be correctly.
CAM Modular Error.
Change for another CAM.
Smart Card no authorization
Change for an authorized smart card
Incorrect insertion of CAM or Smart card.
Correctly insert CAM and Smart card.
39
5 Terminology
A - Z
Abbreviation
Specific Meaning
AES
Audio Engineering Society
ASI
Asynchronous Serial Interface
BISS
Basic Interoperable Scrambling System
BNC
Bayonet Nut Connector
CI
Common Interface
CVBS
Composite Video Broadcast Signal
DVB
Digital Video Broadcast
DVB-C
DVB-Cable
DVB-S/S2
DVB-Satellite
DVB-T
DVB-Terrestrial
EBU
European Broadcasting Union
ETSI
European Telecommunications Standards Institute
FEC
Forward Error Correction
HD
High Definition
HDMI
High Definition Multimedia Interface
ISO
International Standard Organization
ITU
International Telecommunications Union
LNB
Low Noise Block Converter
MPEG
Moving Pictures Experts Group
PCMCIA
Personal Computer Memory Card International Association
RTP
Real-time Transport Protocol
SD
Standard Definition
SDI
Serial Digital Interface
TS
Transport Stream
UDP
User Datagram Protocol
40
6 SPECIFICATIONS
AC Power Input, Single Power Supply
Voltage 100-240 VAC, Dual
Switching Supplies
Current Max 60 Watts, <.2
Amps Typical
Frequency 47-63 Hz
Environmental
Operating Temperature 0 to 50 C
Maximum Altitude 10,000 Ft., 3048 Meters,
AMSL
Humidity 95%, Non-Condensing
RF Input
Frequency Range 57-803 MHz
Broadcast Channels 2-69
CATV Channels 1-125
Impedance 75 Ohms, (50 Ohms
Optional)
Input Connector Type 'F' Female
RF Bandwidth 6 MHz
Demodulator Input Board
Type ATSC, 8-VSB, Standard Other Formats Available, Consult
Factory
Adaptive Equalizer Xilinx Version 7, 4096 Taps
Input Data Rate 19.392658 Mb/sec
SNR (MER) Threshold 15dB
RF Sensitivity >-63dBm UHF, >-72dBm Band III,
>-82dBm Band I
RF Output
Frequency Range 44-850 MHz, Direct Digital
Frequency Step Size 1KHz
Frequency Accuracy <± 2 ppm
Frequency Stability <±2 ppm
Output Level -20 to 0 dBm
Impedance 75 Ohms, (50 Ohms Optional)
Output Connector Type 'F' Female
Spurious Output -60 dBc
Return Loss (VSWR) >17dB (VSWR 1.329:1)
Mechanical
Size 480mm x 40mm x
44mm
Weight 12 Pounds
Chassis Expansion Slots 2