Techly I-ALARM-KIT001 Installation Manual

WIRELESS
GSM/APP
www.techly.com
Installation manual
SMS/GSM Alarm Wireless Starter kit
UP TO 159
ACCESSORIE
EN
DE ITFR
2
Features
- GSM transmitter
- Supports up to 10 remote controls, 99 wireless accessories and 50 RFID tags
- Can store up to 5 phone numbers, 5 SMS numbers
- Arm / disarm the system by SMS, phone call, or App (on iOS or Android)
- Can be disarmed by RFID tag
- Call function from the panel
- SMS alerts for power failure, power recovery and low battery
- Audio surveillance of the site from distance
- 2 x 800mAh lithium batteries included (8h battery life in standby mode)
Specications
Product name
I-ALARM-KIT001
SKU
I-ALARM-KIT001
Control panel power supply
Input: AC 110-240V / 50-60 Hz Output: DC 12V / 800 MA
GSM working frequency
850 / 900 / 1800 / 1900 mHz
Radio-frequency
433.92MHz (±75KHz)
Transmission distance
80m in open space
Standby current
80ma
Alarm current
300mA
Backup batteries
Lithium Batteries: 3.7V / 800 mAh x 2 (BL-5B) (8h battery life in standby mode)
Internal siren
95dB
Housing material
ABS plastic
Operating conditions
Temperature: -10°C~55°C
Humidity: ≤ 80% (non-condensing)
Control panel dimensions (L x W x H)
188 x 125 x 25 mm
Box content
Control Panel x1 Motion Detector x1 Door / Window Contact x1 Remote Controls x2 RFID Tags x2
AC Adaptor x1 User manual x1
EN
DE ITFR
3
www.techly.com
Control Panel Layout (Front)
Control Panel Layout (Back)
Plans and position the alarm system
Power On/O
Adapter interface 24h Zone Electronic
lock
Wired siren
GND
SPK
LOCK
Z1 +12V GND
Call
Clear
RFID Reader Home Mode
LCD Display
Disarm
Record
Arm
SOS
Monitoring MIC
Speaker
Power Supply Interface
Tamper Switch
Power Switch
Battery Compartment
SIM Card Slot
Control panel
Remote control
Outdoor siren
Zone Sensor 1: "Front door"
Zone Sensor 2: "Living room PIR"
Zone Sensor 3: "Entrance window"
Zone Sensor 4: "Terrace Window"
Zone sensor 5: "Terrace door"
Zone sensor 6: "Bedroom Window"
Zone Sensor 7: "Bedroom PIR"
Zone Sensor 8: "Gas kitchen"
Zona sensor 9: "Bath water"
www.techly.com
A
B
C
1
2
3
4
5
7
8
9
9
3
A
1
C
B
2
7
8
5
4
EN
DE ITFR
4
Quick Start-up Guide
Connect your System
Using the GSM transmitter (SIM card)
Open the battery compartment at the back of the control panel and insert a SIM card in the control panel.
Important
Before using the Alarm System in GSM mode, you need to purchase a SIM card that works on the GSM network with 850 / 900 / 1800 / 1900 MHz frequency. We recommend you to subscribe to a plan with unlimited texts and one hour of voice. For more information, please contact your local reseller.
Important
Make sure the SIM card does not require any PIN code. For more information, please contact your local reseller.
Turning your System on
1. Plug the AC adaptor to an AC socket.
2. Plug the output connector of the AC
adaptor into the adaptor interface in the battery compartment at the back of the control panel.
3. Turn the power switch to "ON" (in the
battery compartment at the back of the control panel).
EN
DE ITFR
5
www.techly.com
Mount the Control Panel
Before mounting the control panel on the wall, make sure the reception of the
GSM signal is sucient.
Fix the wall-mounting bracket on the wall with screws. Wedge the panel on the
bracket, make sure they t well.
Basic Operations
Arm the System
Press the Arm button " " on the control panel. The control panel beeps once: the system is armed. The LCD display indicates "Armed" and the Arm icon on the control panel is lit.
Note
If the Entry / Exit Delay is activated, all zones except the 24h zone will be armed after the delay set (refer to the instructions on page 10 of this manual “Entry / Exit Delay”).
Disarm the System
Type your user code and press the Disarm button "
" on the control panel. The
control panel beeps twice: the system is disarmed.
Home Mode
Press the Home button " " on the control panel. The control panel beeps once: the system is armed in Home Mode.
All the sensors assigned to the Normal zone are armed. The sensors assigned to the Home zone are disarmed.
Emergency Mode
Hold the “#
SOS
” button for 3 seconds. The alarm is triggered immediately and the siren rings out. At the same time, the control panel dials the stored phone numbers.
EN
DE ITFR
6
Speed Dial
Press the Call button “ ” on the control panel for 3 seconds: the panel auto-dials the rst stored phone number. Press the Call button “ ” to end the call.
Hands-free Phone Call from the Panel
Through GSM
Press the Call button“ ” on the control panel, type the phone number you wish to call and press the Call button “ ” again.
Record / Play a Voice Memo
Long press the Record Voice Memo button to record a 10-second voice message. The Play Voice Memo Button blinks when a message has been recorded. Push the center of the RFID reader in the control panel to listen to the voice memo. The
LED indicator turns o when the voice memo is being played. Touch it again to
replay the memo.
Hard Reset
Turn the control panel on. Press the tamper switch at the back of the control panel 5 times wirthin 5 seconds after having turned it on.
Settings will be restored to default values. Stored phone numbers and connected accessories will be cleared.
EN
DE ITFR
7
www.techly.com
Setup from the control panel
The Alarm System must be set up before using for the rst time. During the setup
of the system, the control panel can be powered either by the AC power adapter or by the backup batteries.
Default codes
- Admin code (necessary to set up your system): 123456
- User code (necessary to disarm your system or stop the alarm): 1234
- Duress code: 1111 (enables you to trigger a duress alarm)
- Open door code: 8888 (enables you to open an electronic door lock plugged to
your control panel)
All access codes can be changed. We recommend you to change these codes before using your system for the rst time.
The control panel of your alarm system features an LCD display that enables you to navigate through the menu of the control panel and set up your alarm system.
To enter the setting menu, type [your admin code + Enter] on the control panel.
In the table on the next page, each column represents a menu or a sub menu. Each menu or submenu will be displayed on one of the two lines of the LCD display. On the LCD display, the current menu, submenu, or setting is shown on the line at the bottom, while the previous menu or submenu is shown on the line at the top.
Navigate and select the setting you wish to modify with the keys “
” or “ ”, and
enter each menu or sub menu by pressing “Enter”.
How to use the keyboard
“ ” = delete “ ” = move forward “ ” = move backward “Enter” = select / conrmEsc” = back / previous step in the menu / cancel
The tables on the next pages summarize all the settings that can be accessed and
modied on the control panel.
EN
DE ITFR
8
Main Menu Sub Menu 1 Sub Menu 2 Sub Menu 3
Phone numbers
Phone [1~5] is:
-
SMS Num [1~5] Is:
Accessories
Remote & Keypad
Add a new 01/10 30
Delete All 1=YES 0=NO
Delete a Remote Input 01-10:
Accessories
RFID Tag
Add a new 01/50 30
Delete all 1=YES 0=NO
Delete a Tag Input 01-50:
Accessories
Wireless
Sensors
Add a new
Home Zone Delay Zone
Normal Zine
24-H Zone
Delete all? 1=YES 0=NO
Delete a Sensor Input 01-99:
Accessories
Test Mode
-
EN
DE ITFR
9
www.techly.com
Comments
Select the phone or SMS number you want to edit, type in the phone number and conrm with
the key "Enter". Use the key "
" to clear.
5 phone numbers and 5 SMS numbers can be stored in the control panel.
The LCD screen displays “01/10” (at the left), which indicates the number of the remote control you are about to connect (01 is the current remote control, 10 is the total number of remote controls you can connect), and "30" (at the right), which indicates the time remaining to connect the remote control. Press any key on the keypad or remote control, you hear one beep: the connection is successful.
Once the remote control has been added, the countdown starts over from 30 so that you can register another remote control in control panel (up to 10 remote control can be registered in the control panel). Press Esc to exit.
Enter the number of the Remote Control you wish to delete and press "Enter".
The LCD screen displays “01/50” (at the left), which indicates the number of the RFID tag you are about to connect (01 is the current RFID tag, 50 is the total number of tags you can connect), and "30" (at the right), which indicates the time remaining to connect the RFID tag. Swipe the RFID tag in front of the RFID reader, you hear one beep: the connection is successful.
Once the RFID tag has been added, the countdown starts over from 30 so that you can register another RFID tag in control panel (up to 50 tags can be registered in the control panel). Press Esc to exit.
Enter the number of the RFID tag you wish to delete and press "Enter".
Select the sensor type you wish your sensor to be assigned to (Normal Sensor, 24 Hour Sensor, Delay Sensor, or Home Sensor), press “Enter” to conrm. For more information on zone setup, please refer to page 14 of this manual.
The LCD screen displays “01/99” (at the left), which indicates the number of the sensor you are about to connect (01 is the current sensor, 99 is the total number of sensors you can connect), and "30" (at the right), which indicates the time remaining to connect the sensor. Trigger the sensor, you hear one beep: the connection is successful.
Once the sensor has been added, the countdown starts over from 30 so that you can register another sensor in control panel (up to 99 sensors can be registered in the control panel). In such case, the sensor will be added to the same zone. Press Esc to exit.
Enter the number of the sensor you wish to delete and press "Enter".
Trigger the sensors you have previously connected to the control panel. You hear 1 beep, the LCD screen displays the signals that have been respectively sent by each sensor triggered. Make sure all the sensors you have triggered are mentioned on the LCD screen. Press “Esc” to exit the test mode.
This mode enables you to test if the sensors have been connected successfully to the control panel.
EN
DE ITFR
10
Main Menu Sub Menu 1 Sub Menu 2 Sub Menu 3
System Setting
Date and Time
YYYY-MM-DD TIME
System Setting
Date Format
System Setting
Entry Exit Delay
Entry Delay 000-300
Exit Delay 000-300
System Setting
Auto Arm / Disarm
Auto Arm Time <00:00>
Auto Disarm Time <00:00>
ON or OFF?
System Setting
Control by Phone
ON or OFF? -
System Setting
GSM Fail Alarm
ON or OFF?
System Setting
Keypad tones
ON or OFF? -
System Setting
Access code
Admin Code 123456
User Code 1234
Duress Code 1111
Open Door Code 8888
EN
DE ITFR
11
www.techly.com
Comments Note
(e.g. 2014-06-20 14H30)
This function can be used if you do not want to bring a remote control or RFID tag with you. When the system is armed, you hear one beep every second to remind you to leave. The beep rhythm speeds up during the last 10 seconds. If an intruder is detected, the alarm will be delayed accordingly.
Time is calculated in seconds. The Entry and Exit Delay can be set from 0 to 300 seconds.
The entry and exit delays only work for sensors connected as Delay Zone accessories (see "Wireless" on page 8).
The Entry Delay gives you time to disarm the system on the control panel without triggering an alarm. The Exit Delay gives you time to arm the system on the control panel and leave your home without triggering an alarm.
You can set up the system to arm and disarm
automatically at a dened time every day.
Setting Auto Arm and Auto Disarm to the exact same time will deactivate the function.
You can activate or deactivate the control of your system by phone call. Activating the control by phone call enables you to arm and disarm the system and monitor your home by phone call.
See instructions on page 14 for more information on the control of the system by phone call.
Notication of SIM/ GSM signal problem.
Activate or deactivate the sound when typing on the keyboard of the control panel.
Your admin code enables you to enter the setup menu. Default admin code: 123456
It is recommended to change all codes before using your system
for the rst time and to keep
your codes secret
Your user code enables you to disarm the system on the control panel. The user code is the access code requested when you call the control panel. Default user code: 1234
In case of emergency, when you are requested to disarm the system by force, it is recommended to disarm your system with your Duress Code. The panel will silently dial the stored phone numbers. Default duress code: 1111
You can open electronic doors using this code. The door must be wired to the [LOCK] interface on the back of the control panel.
EN
DE ITFR
12
Main Menu Sub Menu 1 Sub Menu 2 Sub Menu 3
System Settings
Ring Times
<1-9>: 5 -
System Settings
Siren Alert Time
<1-9Min>: 3
System Settings
Backlight Time
<0-120s>: 30 -
System Settings
Siren Setup
Wired Siren
Siren Switch
ON/OFF
Arm/Disarm Tone
ON/OFF
Built-in Siren
Siren Switch
ON/OFF
Arm/Disarm Tone
ON/OFF
Wireless Siren
Siren Switch
ON/OFF
Arm/Disarm Tone
ON/OFF
System Settings
User ID
On / O -
Disarm Upload
On / O -
System Settings
Call Recycle
<1-9>: 3
System Settings
Language
- -
System Settings
Reset
1=YES 0=NO -
System Settings
About
About Jun 4 2014 -
History
-
- -
EN
DE ITFR
13
www.techly.com
Comments Note
Enter the value (from 1 to 9) and conrm with "Enter".
This function enables you to determine the number of times the control panel will ring before taking your call (for control by phone call).
Enter the value (from 1 to 9) and conrm with "Enter".
This function enables you to determine for how long the siren rings out in case of alarm.
Enter the value (from 0 to 120) and conrm with "Enter".
Default setting is 30 seconds.
Enable / Disable the siren. Default setting: On
Wired siren refers to a siren connected to the control panel by wire.
Arm / Disarm silently. Default setting: On
Enable / Disable the siren. Default setting: On
Built-in siren refers to the siren featured in the control panel.
Arm / Disarm silently. Default setting: On
Enable / Disable the siren. Default setting: On
Wireless siren refers to a siren connected to the control panel by radio-frequency.
Arm / Disarm silently. Default setting: On
When Disarm Upload is on, the system will upload the history of arm/disarm events to the to the CMS.
W
hen the alarm is triggered, the control panel dials the numbers you have stored. If you do not disarm the system, the control panel will call you again (up to 9 times). The “Call Recycle”
function enables you to dene the number of times the control
panel attempts to call you. Default setting:
3 times.
Select the language you wish to choose and conrm with
"Enter".
Languages available may vary depending on the version of your product.
All system settings will be restored to default setting. Stored phone numbers and connected accessories will be cleared.
Choose the event log you need to track, press “Enter”.
The control panel keeps in record the latest 150 event logs.
EN
DE ITFR
14
Zone setup of accessories
Every detector can be assigned to 4 dierent categories of zones: Home Zone,
Delay Zone, Normal Zone and 24-H Zone. To assign a detector to a zone, follow the instructions on page 8 of this manual (the zone will be assigned at the time of connection of the accessory).
Normal zone
When the system is armed, if a sensor is triggered, the siren rings out. When the system is disarmed, sensors do not trigger an alarm.
24h zone
Regardless the system is armed or disarmed, sensors assigned to the 24h zone can trigger an alarm. It is recommended to assign smoke detectors, gas detectors and outdoor beam sensors to the 24-H zone.
Delay zone
If you want to set up the entry and exit delay functions, corresponding sensors must be assigned to the Delay zone. Once the delay time has been set up, the sensors will not trigger the alarm during the delay set. Refer to the instructions “Entry and Exit Delay” on page 10 of this manual. It is recommended to assign the Door / Window Contact to the Delay zone.
Home zone
When the system is armed in Home Mode, the sensors assigned to the Home zone do not trigger an alarm. It is recommend to assign motion dectors to the Home zone so that you can have your system armed in Home Mode when you are home and move inside your home without triggering any alarm.
Control by phone call
This feature is available only after having enabled it from the control panel, as explained on page 10 of this manual.
Method 1
When an alarm has been triggered, the control panel dials the stored phone numbers. When you pick up the phone, follow the voice instructions to control the panel from distance (refer to the instructions in the table below).
Method 2
1. Dial the telephone number of your control panel (either the number of the SIM card in your control panel or the number of the landline to which your panel is connected). After getting through, the voice instructions will guide you to enter your access code.
2. Enter your user code, followed by “#”.
3. A voice gives you the options you can select.
4. Select the operations to control the panel (see instructions in the table below).
EN
DE ITFR
15
www.techly.com
Note
The call will end automatically if you do not send any command within 30 seconds.
Table of commands for control by phone call
Command Function
Press “1” Arms the system
Press “0”
- Disarms the system and turns the
siren o
- Stops monitoring without hanging up
- Stops the phone call function without hanging up
Press “3” Phone call with control panel
Press
- Starts audio monitoring mode (not limited in time)
- Stops the built-in siren and the wireless siren (if connected to the control panel)
Press “6” Turns all sirens o
Press “9”
- Turns the built-in siren on (whether the siren ringing settings is ON or OFF)
- Turns the wireless siren on (if connected to the control panel)
Press “#”
- Turns all sirens o
- Exits control by phone call
- Stops call recycles
Note
In GSM mode, the audio monitoring is not limited in time.
EN
DE ITFR
16
Setup by SMS
IMPORTANT: BEFORE USING FOR THE FIRST TIME
Insert a SIM card in the control panel before starting SMS operations. Make sure the SIM card does not require any PIN code.
SAVE A SMS NUMBER IN THE CONTROL PANEL (using the control panel).
Only stored numbers can control and congure the system.
(Refer to the instructions page 8)
Each SMS operation dened in this user manual will be illustrated as follows:
You send:
SMS Command
The control panel replies:
Control panel’s reply
The rst green speech bubble is the
SMS command sent by the user.
The rst grey speech bubble is the
reply sent by the control panel.
The speech bubbles that follow are the dialogue between the user and the control panel (SMS sent by the user are in green SMS sent by the control panel are in grey).
The system is in English by default. To change the system language, refer to the instructions on page 22 of this manual.
Important
When replying to the control panel by SMS, make sure no space follows punctuation marks like "." or ":". For examples, to store SMS numbers, your SMS must be formatted as follows:
SMS numbers:
1.067890033
2.067890022
3.067890011
4.067890000
5.
No space after "1."
EN
DE ITFR
17
www.techly.com
Disarm the System
Send:
0
System disarmed.
Arm the System
Send:
1
System armed.
Home Mode
Send:
2
System in home mode.
Setting Enquiry
Send:
00
System:Disarmed AC power:on
Note
The values indicated hereinabove will change after having set up the system.
EN
DE ITFR
18
Store Phone Numbers
Send:
5
Phone numbers:
1.
2.
3.
4.
5.
Copy, paste, then edit (case sensitive):
Phone numbers:
1. 067890033
2. 067890022
3. 067890011
4. 067890000
5.
Ok
Store Phone Numbers for SMS Notications
Send:
6
SMS numbers:
1.
2.
3.
4.
5.
Copy, paste, then edit (case sensitive):
SMS numbers:
1. 067890033
2. 067890022
3. 067890011
4. 067890000
5.
Ok
Note
The rst SMS number will receive SMS notications when the system
is disarmed by RFID tag. To start
receiving these notications, you
must rename the RFID tags. Up to 4 RFID tags can be renamed. Other tags will be attributed a number based on the order of registration to the control panel. Refer to the instructions on page 8 to learn how to register an RFID tag in the control panel.
EN
DE ITFR
19
www.techly.com
Rename Zones
Send "91~99". For example for zone 1, send:
91
Zones names:
1.
Copy, paste, then edit (case sensitive):
Zones names:
1. Entrance door sensor
Ok
Note
Zones 1 to 9 can be renamed. The name of the zone cannot consist of more than 30 Latin characters. Zones 10 to 99 cannot be renamed.
SMS Alert for Accessory Low Battery
(available for two-way acessories such as Motion Detectors)
For accessories assigned to zones that have been renamed, an SMS will be sent under the format “Zone name + low battery”.
Bedroom PIR low battery
For accessories assigned to zones that have not been renamed, an SMS will be sent under the format “Zone
number + low battery”.
Zone 10 low battery.
SMS Alert for Accessory Tamper Alarm
(available for two-way acessories such as Motion Detectors)
For accessories assigned to zones that have been renamed, an SMS will be sent under the format “Zone name + tamper alarm”.
Bedroom PIR tamper alarm.
For accessories assigned to zones that have not been renamed, an SMS will be sent under the format “Zone
number + tamper alarm”.
Zone 10 tamper alarm.
EN
DE ITFR
20
Rename RFID Tag
Send:
10
Rename RFID tag names:
1.
2.
3.
4.
Copy, paste, then edit (case sensitive):
Rename RFID tag names:
1. Tom
2. Nurse
3. Nancy
4. David
Ok
Note
The rst SMS number will receive SMS notications when the system
is disarmed by RFID tag. To start
receiving these notications, you
must rename the RFID tags. Up to 4 RFID tags can be renamed. Other tags will be attributed a number based on the order of registration to the control panel. Refer to the instructions on page 8 to learn how to register an RFID tag in the control panel.
Entry and Exit Delay Time
Send:
11
Entry delay time(0-300sec):0 Exit delay time(0-300sec):0
Copy, paste, then edit (case sensitive):
Entry delay time(0-300sec):10 Exit delay time(0-300sec):20
Ok
Note
This function can be used if you do not want to bring a remote control or a RFID tag with you.
When you arm the system, the system will be armed after the delay set. When you disarm the system, the system will be disarmed after the delay set.
When arming the system, you hear one beep every second to remind you to leave. The beep rhythm speeds up during the last 10 seconds. If an intruder is detected, the alarm will be delayed accordingly.
EN
DE ITFR
21
www.techly.com
Siren Volume and Ringing Time
Send:
12
Siren volume(0=Mute,1=High):1 Siren ringing time(1-9min):3
Copy, paste, then edit (case sensitive):
Siren volume(0=Mute,1=High):0 Siren ringing time(1-9min):5
Ok
Disarm Password
Send:
13
Disarm password (4 digits): 1234
Copy, paste, then edit (case sensitive):
Disarm password (4 digits): 4321
Ok
EN
DE ITFR
22
Change System Language
Send the code corresponding to the language you want to set. For example, for English, send “0001”.
0001
Ok
Refer to the table below for the full list of languages:
0001 English 0002 French 0003 German 0004 Italian
Languages available may vary depending on the version of your product.
Restore System to Factory Settings by SMS
Send:
0000
Ok
The settings will be restored to default values. Stored phone numbers and connected accessories will not be deleted.
Note
Only stored numbers can send the SMS to restore factory settings.
EN
DE ITFR
23
www.techly.com
Accessories
Wireless Remote Control
Home Mode
Arm
SOS
Disarm
LED indicator
Arm the system
Press the Arm button " " to arm the alarm system. The LED indicator lights up (the control panel beeps once). The system is armed.
If an intruder is detected, the siren
rings out. (The siren turns o after 5
minutes as per default settings.) In the meantime, the system dials the stored phone numbers automatically.
Disarm the system
Press the Disarm button " " to disarm the alarm system. The LED indicator
turns o (the control panel beeps
twice). The system is disarmed.
Home Mode
Press the Home Mode button " " on the remote control. The system state LED is on. All the sensors in regular zones are armed except those in the Home Mode zone. The sensors in the Home Mode zone are disarmed so that users can move inside their home.
EN
DE ITFR
24
Mute Mode
Press the Home Mode button " " and then the Arm "
" or Disarm " " button immediately after. Doing so, the control panel does not beep when you arm or disarm your system.
Emergency Mode
Regardless the status of the system, the alarm is triggered when the SOS button "SOS" is pressed on the remote control.
At the same time, the control panel
sends a notication by SMS ("RC-01
SOS", 01 being the remote control's
number) and dials the pre-stored phone numbers.
Register in the control panel
Refer to the instructions in the table on page 8 of this manual "Remote & Keypad".
Specications
Power supply
DC 3V (CR2025 button battery x1)
Static current
≤10 uA
Operating current
≤7 mA
Transmission distance
≤ 80 m (in open area)
Radio-frequency:
433MHz (±75KHz)
Housing material
ABS plastic
Operating conditions
Temperature: -10°C ~ +55°C
Relative Humidity: ≤80%
(non-condensing)
Dimensions
57 x 31 x 11 mm
EN
DE ITFR
25
www.techly.com
Wireless Motion Detector
Design
1. LED indicator
2. Detection window
3. Bracket
LED indications
Blinks continuously: self-testing Blinks once: an intruder is detected Blinks twice: self-testing is complete;
entering working mode. Blinks once every 3 seconds: under­voltage indication, the batteries must be replaced. (You will be informed by SMS when the batteries are low if the motion detector is registered in the control panel.)
PCB Layout
Alarm zone setup Tamper switch*
Infrared sensor**
AA 1.5V LR6
Antenna
LED working
indicator
*Tamper switch
When the alarm system is armed, the tamper switch will trigger the alarm if the case is opened.
**Infrared sensor
Detects the infrared rays released by human body motion. Do not touch the surface. Keep the surface clean.
1
2
3
EN
DE ITFR
26
Usage
Open the case and remove the battery activation strip. Self-testing will start for 30 seconds.
When the sensor is in operation, if it is triggered more than twice within 3 minutes, it will switch to standby mode to save power. If no movement is detected within the next 3 minutes, the sensor goes back to working mode.
Connect Button
Register in the control panel
Navigate through the menu of the control panel and reach "ADD A NEW" (Wireless Sensor). Press the Connect button at the back of the motion sensor or trigger the sensor (by moving in front of it) to register the detector in the control panel.
Installation
Avoid mounting the detector close to windows, air conditioner, heater, refrigerator, oven, sunshine and places where the temperature changes fast or where the air
stream ows frequently.
If two detectors are installed in the same detection scope, adjust the location to avoid interferences and false alarms.
Fix the bracket on the wall with screws and attach the detector to the bracket. Adjust the bracket to change the detection distance and angle. It is recommended to mount the detector 2.2 m from the ground.
Top
Bottom
Ground
2.2 m
The detector is more sensitive to cross movements than vertical movements.
EN
DE ITFR
27
www.techly.com
Testing
A. After the installation, turn the detector on. After one minute of self-testing,
press the test button, walk in the scope of detection and watch the LED indicator to make sure the detector is working.
B. The LED indicator blinks once when body movement is detected.
C. Adjust the detector angle to achieve the best detection performance.
Specications
Power supply
DC 3V (AA 1.5V LR6 Batteries x 2)
Static current
≤ 30uA
Alarm current
≤ 15 mA
Detection scope
8m / 110°
Transmission distance
≤ 80m (in open area)
Radio-frequency
433 MHz (±75 KHz)
Housing material
ABS plastic
Operating conditions
Temperature: -10°C~55°C
Relative humidity: 80% (non-
condensing)
Detector dimensions (L x W x H)
107 x 53 x 32 mm
Bracket dimensions (L x W x H)
52 x 30 x 26.5 mm
Detection Scope
110°
Top view
0m 2m 4m 6m 8m
2m
0m
Side view
EN
DE ITFR
28
Wireless Door / Window Contact
Features
This Door / Window Contact can be installed on doors, windows, and any other objects that open and close. The sensor sends a signal to the control panel when the magnet is separated from the transmitter.
Thanks to the tamper switch, any attempt to remove the cover of the Door / Window Contact will trigger the alarm.
Design
LED indicator
Magnet
Transmitter
PCB Layout
Tamper switch
AA 1.5V LR6 battery
Zone setting
LED indications
Blinks once: the door or window is open and the transmitter sends a signal to
the control panel.
EN
DE ITFR
29
www.techly.com
Installation
- Open the case and remove the battery
activation strip.
- Mount the sensor on the door and the magnet
on the door frame.
- Make sure the magnet is placed above the
transmitter.
- Mount the magnet max. 1 cm away from the
transmitter and secure the transmitter and magnet with double-sided tape or screws.
- Avoid mounting the sensor in areas with a
large amount of metal or electrical wiring such as a furnace or utility room.
Specications
Power supply
DC 1.5V (AA 1.5V LR6 battery x 1)
Static current
≤ 30 uA
Alarm current
≤ 40mA
Transmitting distance
≤80 m (in open area)
Radio-frequency
433 MHz (±75 KHz)
Housing material
ABS plastic
Operating conditions
Temperature: -10°C~55°C
Relative humidity: ≤ 80% (non-condensing)
Transmitter dimensions (LxWxH)
71 x 35 x 17.5 mm
Magnet dimensions (LxWxH)
51 x 12 x 13.5 mm
EN
DE ITFR
30
RFID Tag
Features
The RFID tag enables you to disarm your system or unlock electronic door locks.
Register in the control panel
Refer to the instructions in the table page 8 of this manual (“RFID TAG”).
Specications
Dimensions
45 x 30 x 7 mm
Loading...
+ 102 hidden pages