Installation Instructions for
ALLEN
WRENCH
1
BASE PLATE
SET SCREW
Turbo Column
OUTDOOR
GP I :ENERAL RODUCT NFORMATION
This product is suitable for wet locations.
Refer to the product specsheet for dimming information.
920OCTURBO
700OCTUR_
CAUTION RISK OF FIRE-
This product must be installed in accordance with
the applicable installation code by a person familiar
with the construction and operation of the product
and the hazards involved.
Use minimum 90°c supply conductors.
1.0
1.5
Install the Column
1A
Loosen the four set screws on(Do Not Remove)
1
column base with the provided Allen wrench and
remove the base plate.
1B
2
1C
COLUMN BOTTOM SLOT
Align the tab on the column top to the slot in the
4
column base, insert the fixture wires into the column
base, and assemble them together.
5
Secure them together by installing the Allen bolts and
washers with the provided Allen wrench.
COLUMN TOP TAB
4
ALLEN BOLT
& WASHERS
5
ALLEN WRENCH
1D
33
Bring the power wires to the fixture location in
2
accordance with local electrical codes.
3
Mount the base plate to an even and smooth surface
using the provided template on page 3.
NOTE: anchor/lag bolts, nuts, and washers not
provided.
ALLEN
WRENCH
SET SCREW
Carefully install the column assembly onto the base
6
plate and secure it in place by tightening all 4 set
screws.
1

Wire the Column
2A
2B
4
4
8
5
6
7
Loosen the access panel set screw on(Do Not Remove)
1
column base with the provided Allen wrench.
2
Pull away the top of the access panel and lift it
completely out the column base.
3
Power the fixture using the following steps or wiring
diagrams according to the options included with the
fixture.
For Standard options,go to step 2B.
For Photocell/Surge options,go to step 2C.
For In-line Fuse/Surge options,go to step 2D.
For Photocell/In-line Fuse/Surge options, go to step 2D.
Connect the red and black wires from the column top
4
respectively to the red and black wires in the column
base by inserting them into an open port in wire
connectors. Close the levers to lock the wires in place.
5
Connect the fixture to a suitable ground in accordance
with local electrical codes.
6
Connect the neutral power line wire to terminal block
connected to the white wires.
7
Connect the hot power line wire to terminal block
connected to the black wires.
8
Use the gray and purple dimming wires for 0-10v
dimming application (if not in use, make sure to cap
these wires off).
9
Reinstall the access panel (reversal of section 2A).
Warning: The purple and gray wires are only used for 010v dimming. For all other applications, do not connect
the gray and purple wires.
2