SCREW HOLE
TEMPLATE
MODE S082KA
SCREW HOLE
SCREW HOLE
TESTING
ALARM OUTPUT AND PANIC BUTTON TEST
To test the alarm output, press the PANIC button located on
front of the unit. (THIS UNIT IS VERY LOUD, COVER THE
SIREN ON THE FRONT OF THE UNIT BEFORE ACTIVATING).
The unit will immediately sound a piercing alarm siren. To
disarm the unit, enter your security code followed by the
#ON/OFF button. (If you have not entered a security code
the default is 0 and S082K is 5
CHIME TESTING
1.Set the function switch to the CHIME position.
2.Enter the security code followed by the #ON/OFF button,
the ALARM LED will illuminate. If this does not happen
repeat steps 1 and 2.
3.Close the door and then open it again, a pleasant chime will
sound 3 times.
4.To disarm the unit, enter the security code followed by the
#ON/OFF button.
5.As long as the unit is in the ARM mode, the chime will
continue to sound until DISARMED .
ALARM TESTING
1.Set the function switch to the INSTANT or DELAY
position.
2. Enter the security code followed by the #ON/OFF button,
the ARM LED will turn on. If this does not happen, repeat
steps 1 and 2.
3. Close the door and open it again in INSTANT mode, the
alarm sounds immediately. If the alarm is in DELAY mode,
the alarm will emit a low beep tone to alert your to disarm the
unit, if not disarmed, the unit will then sound a piercing alarm.
4.To disarm the unit, enter the security code followed by the
#ON/OFF button.
Note: in both modes, CHIME or ALARM (instant / delay) the unit will continue to
sound until DISARMED . The unit will only sound the ALARM if ARMED in
the ALARM mode. If armed in the CHIME mode the unit will sound only the CHIME.
If function switch is changed after the unit has been activated, this will not alter the
sound being produced.
OPERATION
ALARM MODE
1.Before arming the unit slide the function switch to the
INSTANT/DELAY position.
2.To arm the S082X / S082K, enter the security code
followed by the #ON/OFF button, the ARM LED will
turn on. If this does not happen repeat steps 1 and 2.
3.INSTANT mode.
When an entry is detected. The alarm sounds
immediately. This is used to protect you when you
are at home.
4.DELAY mode.
This mode is used when you are leaving your home.
On your return, an entry alert beep tone will sound
to alert you to disarm the unit. If the unit is not
disarmed within10 seconds of entry, the alarm will
sound a110db (S082KA is 115db) alarm siren.
5.The 110db/115db alarm will sound for about 30/36
seconds, while the alarm is sounding or during the
entry alert time the security code can be entered to
disarm the unit.
6.To disarm the unit, enter the security code followed by
the #ON/OFF button.
CHIME MODE
1.Before activating the chime, slide the function switch
to the CHIME position.
2.Enter the security code followed by the #ON/OFF button.
3.The ARM LED will illuminate to verify the unit is ON,
followed by a short beep. If the ARM light does not
illuminate this indicated the unit is OFF.
4.The chime will sound if there is an entry. The chime will
sound for each entry until the unit is turned OFF(disarmed)
NOTE: The position of the function switch does not
necessarily indicate the mode the unit is in
(CHIME / INSTANT / DELAY). Each time before
activating the unit, set the function switch to the correct
position for the mode desired.
PANIC ALARM
The red PANIC button on the front panel activates the
alarm during a possible emergency.
1.Press the panic button. This will activate the 110db
(S082KA is 115db) alarm siren.
2.Disarm the PANIC alarm, follow the same procedure as
you would to DISARM the unit.
CAUTION
THE MAGNET GUARD IS EXTREMELY LOUD. FOR YOUR
SAFETY. NEVER PLACE THE UNIT CLOSE TO YOUR EARS.
TO TEST THE ALARM, DIRECT THE UNIT AWAY FROM YOU
AT ARMS LENGTH AND ACTIVATE.
PATENT PENDING NOTICE
THIS PRODUCT IS PROTECTED UNDER FEDERAL PATENT. TRADEMARK AND COPYRIGHT
LAWS AND LAWS PREVENTING UNFAIR COMPETITION. NO DUPLICATION OR SIMULATION OF
THIS PRODUCT IS PERMITTED EXCEPT BY WRITTEN AUTHORIZATION OF TECHKO, INC.
TECHKO AND THE CONFIGURATION OF THIS PRODUCT ARE TRADEMARKS OF TECHKO, INC.
COPYRIGHT 1992 TECHKO, INC. ALL RIGHTS RESERVED
Customer Service :
1-888-8TECHKO (1-888-883-2456)
Website: www.techkomaid.com
Mfg. By
9767 Research Drive
Irvine, CA 92618-4626
MADE IN CHINA
SAFETY SECURITY
MAGNET GUARD
MODEL S082X/S082K
S082KA
1
2
3
4
5
#
*
PANIC
S082K
S082X
3
2
1
6
5
4
9
8
7
0
#
*
S082X
OPERATION MANUL
TEMPLATE
MODE S082X
SCREW HOLE
SCREW HOLE
CHANGING A SECURITY CODE TO A NEW CODE
1.Enter the old security code number.
2.Press the* /CODE button.
3.Enter the new code(1 to 12 digits), (S082KA is 1 to 7).
4.Press the */CODE button, the unit will beepo nce to
confirm your new code has been entered.
S082XS082X
33
22
11
66
55
44
99
88
77
00
##
**
S082XS082X
33
22
11
66
55
44
99
88
AFFIX SELF
ADHESIVE
TAPE HERE
Fig.3
77
00
##
**
Fig.2
SENSORS
ON DOOR
S082KA
1
2
3
4
5
#
*
PANIC
SENSORS
ON WINDOW
S082XS082X
33
22
11
66
55
44
99
88
77
00
##
**
S082KA
1
2
3
4
5
#
*
PANIC
MOUNTING
SELECT A MOUNTING LOCATION
NOTE: Before mounting the unit be sure to read theS AFETY
TIPSs ection at the beginning of the manual.
1.Apply double sided tape (included) to back of sensor switch
pair. Mount sensor without wire to the door or window.
Mount the sensors with wire to the door or window frame.
(Fig.2) Be sure the magnetic sensors are mounted no further
than a 1/4f rom each other.
2.Using the mounting plate as template, mark the screw hole
locations and drill two 1/4h oles. Tap the provided screw
anchor into place. (Fig.3)
3.Secure the mounting plate to the wall with the screws
provided.
4.Snap the alarm unit into place on the mounting plate.
AFFIX SELF
ADHESIVE
TAPE HERE
KEY HOLE
FOR WALL
MOUNTING
INSTALLATION
BATTERY INSTALLATION
1.Remove screws from battery compartment located on the
bottom of the unit .(Fig.1)
2.Install 3 AAA batteries / 9V battery. (Not included).
NOTE: When the batteries are installed for the first time or
are replaced the security code will automatically default
back to 0 (S082KA factory code is 5 ) and the LED indicator
will illuminate. This unit will also be in the ARM mode. After
installing the battery to disarm the unit press 0 / 5 and
the #ON/OFF button. A short Confirming beep will sound
and the LED light will go out to verify the unit has been
disarmed.
S082KA
ENTERING CODE TO ARM AND DISARM
1
2
3
4
5
#
*
PANIC
NOTE: The default for the security code is 0 (S082KA default
is 5 ). When the battery is replaced the unit will reset to the
factory set code 0 / 5 .
1.Press the 0 / 5 button or the code that is currently in
memory.(New battery default is 0 / 5 ). If there is an
existing code use that in place of the 0 / 5 .
2.Press the #ON/OFF button, a confirming beep should be
heard.
3.If the wrong security code is entered there will be two tone
beep , this is different from the single beep confirmation.
4.When the unit is armed the ARM LED will illuminate.
3x1.5V AAA 1x9V 6F22
PROGRAMMING
A SECURITY CODE
NOTE: The programmable security code can be a 1 to 12 digit code.
(S082KA is 1 to 7 digits). Shorter codes such as 1 to 4 digits are easy to
remember, long codes can provide greater safety. DO NOT INCLUDE
A 0 IN YOUR CODE (S082X). DO NOT INCLUDE A 5 IN YOUR
CODE (S082KA).
TO PROGRAM A SECURITY CODE AFTER
BATTERY INSTALLATION
1.Press the 0 (S082KA is 5 ) button.
2.Press the */CODE button.
3.Enter the new code (1 to 12 digits), (S082KA is 1 to 7).
4.Press the */CODE button, the unit will beep once to confirm
your new code has been entered.
INTRODUCTION
Congratulations on your purchase of the TECHKO model
S082X/S082KA.The MAGNET GUARD provides detection of
unwanted intruders in your home by detecting entry. This
unit can be mounted on any door or window. Arming and
disarming of the unit is done by entering a security
code on the keypad.
FEATURES
* Requires no wiring or special installation.
* Built-in 110db (S082KA is 115db) alarm siren.
* Up to 12 (S082KA 7 digits) digits programmable
security codes.
* Alarm / chime switchable mode.
* 5-10 seconds entry alarm delay with alert beep tone.
* Magnetic sensor detects entry.
* Direct access PANIC button.
* 4.5V (3 1.5V AAA size) alkaline battery operation
(S082KA uses 9V battery) (Not included).
* Optional AC adaptor power operation for S082KA.
* 2 warning stickers for possible points of entry.
SAFETY TIPS
1.Read all installation and operation instructions
carefully before using.
2.Alarm siren is very loud, never put the unit close to
your ear.
3.Avoid rough handling.
4.Do not install alarm where it will be exposed directly to
sunlight or high humidity.
5.The unit can provide valuable protection for your home
and property if utilized properly. However, this unit can
not guarantee compete protection against burglary
or robbery. Therefore, TECHKO cannot be held liable for
loss or damage which could occur.
6.Keep this manual in a convenient location for future
reference.