24
25
functions description settings
04 – BUSY busy channel lockout OFF/bU
If activated, transmission is not possible on an occupied channel. A
warn tone is audible and the symbol BUSY appears in the display.
05 – NAME channel name 6 digits, A-Z
A six-digit channel name can be programmed. The available symbols are A-Z, 0-9 and the hyphen.
The active space holder blinks. Make your selection by turning the
rotary volume control (5). Advance to the next digit with the V/M
key (2). To return to the prior digit, use the FUN key (1) you return
to the prior one.
Once finished, confirm your selection by pushing the rotary volume
control (5).
06 – TX transmit mode ON/OFF
For deactivation of the transmission mode on the actual channel,
use the option OFF.
07 – REV frequency reverse ON/OFF
This setting concerns only the commercial versions UHF-/VHFCOM.
When using different frequencies for transmission (tx) and reception (rx), the frequencies will be reversed with the setting ON.
08 – TALK tx-frequency adjustment ON/OFF
This setting concerns only the commercial versions UHF-/VHFCOM. When using different frequencies for transmission (tx) and
reception (rx), the transmission frequency will be set to the reception frequency.
09 – SHIFT frequency shift direction OFF/+/-
This setting concerns only the versions UHF-/VHF-COM.
The, for repeater operation, required frequency shift is defined in
its direction. The under #10 (OFFSET) defined frequency shift will
be applied above (+) or below (-) the reception frequency. The according symbols (+ / -) are displayed.
FUNCTION MENU
With the function menu, the available settings can be changed. To access the menu, press the function key FUN (1) for approximately 2 seconds. The display indicates the function its number.
To navigate through the available functions use the channel selectors
of the microphone or turn the rotary volume control.
To activated the selected funtion for editing, push the rotary volume
control. Then, select the function setting with the channel selectors of
the microphone or by turning the rotary volume control (5) and confirm
by pushing the rotary volume control (5).
Via software programming it is possible to deactivate parts (option 110 / channel 11.19) or even the entire menu. This can be useful if the
administrator does not prefer unwanted setting changes by users.
function
description settings
01 – SPK squelch mode SQ/CTC
With the squelch mode selection CTC, the signal will only be audible if the CTCSS/DCS codes matches. The squelch mode setting SQ does not consider the CTCSS/DCS code and any carrier
on the frequency will be audible.
If no CTCSS/DCS code is selected, SQ is the only available mode.
02 – POW Sendeleistung LO/MI/HI
With the PMR and FreeNet versions, the maximum tx-power is limited to 500 mW due to governmental regulations. The only avaiable setting is LO (low).
For the commercial versions UHF- and VHF-COM, the tx-power
settings LO (low) MI (middle) and HI (high) are available.
For programming of the tx-power values, contact your dealer. The
tx-power setup should only be performed by an authorized service
personnell and in compliance with the individual registration.
03 – bAND bandwidth NAR/MID/WIDE
Due to regulations, for the versions PMR and FreeNet, the only
available bandwidth is 12.5 kHz (NAR). For the COM versions NAR
(12.5 kHz), MID (20 kHz) and WIDE (25 kHz) are available.