TDK-Lambda FPS1000 Series, FPS1000-48, FPS1000-12, FPS1000-32, FPS1000-24 Instruction Manual

FPS1000 INSTRUCTION MANUAL
Model FPS1000 FPS1000 FPS1000
V/I -24 -32 -48
24 32 48 29 38.4 58 33 26 17.25 40 31 21
V1 (V) V2 (V)
I1 (A) I2 (A)
Fig. 1: Rated output current vs output voltage
Vout (V)
I1
Iout (A)
I2
1V 2V 3V 4A 5W 6
Input voltage / frequency range
(*1) ---
7
Maximum input current (at 100/200Vac)
A 8 --­9(*2) %
10 (*3) A 11 mS 12 (*5) --­13 (*6) --­14 (*4) mV 15 --­16
PPM/°C
17 (*7)V 18 (*9) --­19
Series operation
(*10)
--­20 --­21 (*8) V 22 --­23 --­24 --­25 --­26 --­27 --­28 --­29 --­30 --­31 ---
32 --­33 --­34 --­35 --­36 --­37 --­38 --­39 --­40 --­41
--­42 --­43 mA 44 Kg 45 ---
Rated output voltage
12
32
48
FPS1000 SERIES SPECIFICATIONS
FPS1000-12
FPS1000-32
FPS1000-48
Output voltage range
10.5~13.2
28.8~38.4
43~58
Output voltage set point
12+/-1%
32+/-1%
48+/-1%
Maximum output power
864
992
1008
Maximum Output Current (Refer to Fig.1)
72
31
21
85~265Vac continuous, 47~63Hz, Single phase
12.0/6.0
Power Factor (Typ)
>0.98 at 115/230V and maximum output power
Inrush current
Less than 40A
Efficiency (Typ)
84/86%
84/86%
85/88%
Hold-up time
20mS typical at 100Vac input, rated output voltage and less than 80% of rated load.
Maximum line regulation
0.40%
Max load regulation
0.80%
Output Ripple and noise pk-pk
200
250
300
Temperature stability
0.05% of rated Vout for 8hrs after 30min warm-up. Constant line, load and temperature.
Temperature coefficient
200
Remote sensing
Possible. Refer to Instruction Manual.
Parallel operation
Possible. Refer to Instruction Manual. Possible. Refer to Instruction Manual.
Over current protection
105~125% of maximum output current. Refer to Fig. 1
Over voltage protection
31~34
41.5~45.5
62~66
Over temperature protection
Inverter shut down method, automatic reset.
Remote On/Off control
By electrical signal or dry contact. ON: 0~0.6V or short. OFF: 2~15V or open.
DC OK signal
Over-Temp. warning
Open collector signal. Refer to Instruction Manual
AC fail signal
Open collector signal. Refer to Instruction Manual
Auxiliary power supply
11.2~12.5VDC. 0.25A Maximum output current. Vout voltage trimming Front panel indicators
I
2
C Interface
Operating temperature-models without IEC inlet
models with IEC inlet
Possible, via Vout Trim pin in the I/O connector. Refer to Instruction Manual. AC OK, DC
OK, DC FAIL
Optional. Refer to Instruction Manual.
0~50°C:100% load. Derate 2%/°C, 50°C to 60°C. Derate 2.5%/°C, 60°C to 7C
Storage temperature Operating humidity Storage humidity
Cooling
Vibration
Shock Conducted emission
Radiated emission Applicable safety standards Withstand voltage
Insulation resistance
Leakage current
Weight (Typ)
Size (W*H*D)
Notes: *1: For cases where conformance to various safety standards (UL, EN etc.) is required,
to be described as 100-240Vac (50/60Hz).
*2: At 100/200Vac, rated load and 25
˚C ambient temperature.
*3: Not applicable for the noise filter inrush curr
ent less than 0.2mS.
*4: Measured with JEITA RC-9131A 1:1 probe, 20MHz B.W. *5: From 85~132Vac or 170~265Vac, constant load. *6: From No-load to Rated load, constant input voltage. Measured at the sensing point in Remote sense. *7: Remote sensing can compensate up to 1V drop on each load wire.
*8: Inverter shut down method. Reset by AC voltage recycle or by On/Off control. *9: Derate Maximum output power by 10% for input voltage less than 100V
RMS
.
*10 For FPS 1000-12/P(S), when used not with FPS-S1U or FPS-T1U
racks, an EMI suppressor clamp should be attached to the AC cable, as close as possible to the AC inlet, to meet class B.
24
FPS1000-24
21.5~29
24+/-1%
960
40
FPS1000
-12 12
13.2 66 72
81/83%
150
14.3~15.7
0~50°C: 100% load. Derate 2%/°C, 50°C to 60°C.
-30~85°C 10~90% RH, no condensation. 10~95% RH, no condensation.
By internal Fans. Variable speed control.
Built to meet ETS 300 019
Built to meet ETS 300 019 EN55022B, FCC part 15J-B, VCCI-B EN55022B, FCC part 15J-B, VCCI-B
UL60950-1, EN60950-1
Input-Output: 3000Vrms, 1min. Input-Ground: 2000Vrms, 1min. Output-Ground:
500Vrms,1min.
More than 100Mohm at 25°C and 70% RH. Output-Ground: 500Vdc
Less Than 1.1mA at 230Vac
2.0
127x41x290mm. Refer to Outline Drawing.
---
Open collector signal. On when Vout 80+/-5% rated output. Max.sink current: 10mA
FPS1000 SAFETY INSTRUCTIONS
SAFETY APPROVALS
UL 60950-1 and CSA22.2 No.60950-1 - UL Recognized. C-UL for Canada. IEC 60950-1 - CB Report and Certicate. EN 60950-1 - CE mark. Marking by the CE Symbol indicates compliance to the Low Voltage Directive of the European Union. A “Declaration of Conformity” in accordance with the preceding directives and standards has been made and is on le at our EU representative TDK LAMBDA UK, located at Kingsley Avenue, Ilfracombe, Devon EX34 8ES, UK.
A “Declaration of Conformity” may be accessed via company website www.uk.tdk-lambda.com/technical-data
CAUTION: The following safety precaution must be observed during all phases of operation, service and repair of this equipment.
Failure to comply with the safety precautions or warnings in this document violates safety standards of design, manufacture and intended use of this equipment and may impair the built-in protections within. TDK Lambda shall not be liable for user’s failure to comply with these requirements.
Vorsicht: Die folgenden Sicherheitsvorschriften müssen vor Inbetriebnahme und in jedem Betriebszustand bei Service oder
Reparatur beachtet werden. Missachtung der Sicherheitsvorschriften und Warnhinweise aus diesem Handbuch führen zur Verletzung der bestehenden Sicherheitsstandards. Bei Betrieb des Gerätes ausserhalb dem bestimmungsgemässen Einsatz können die im Gerät integrierten Schutzfunktionen beeinträchtigt werden. TDK-Lambda ist nicht haftbar für Schäden, die durch Missachtung dieser Sicherheitsvorschriften entstehen können.
CAUTION: FPS1000 units are not authorized for use as critical component in nuclear control systems, life support systems or equipment for use in hazardous environments without the express written approval of the managing director of TDK-Lambda.
Vorsicht: Dieses Produkt ist nicht für die Verwendung als kritische Komponente in nuklearen Steuerungssystemen,
lebenserhaltenden Systemen oder Geräte für den Einsatz in gefährlichen Umgebungen, ohne die ausdrückliche schriftliche Genehmigung durch TDK-Lambda zugelassen.
INSTALLATION (OVERVOLTAGE) CATEGORY& ENVIRONMENTAL CONDITIONS
The FPS1000 units have been evaluated to Overvoltage category II. The FPS1000 units intended for use in the following operation conditions: * Indoor use * Pollution degree 2 * Max. operational altitude: 3000m above sea level *Ambient temperature: -10°C-50°C at 100% load, up to 70°C with output de-rating applied (See Specication)
GROUNDING
FPS1000 units are Class I product. To minimize electrical shock hazard, the FPS1000 units must be connected to an electrical ground. The instruments must be connected to the AC power supply mains through a three conductor power cable, with the ground wire rmly connected to an electrical ground (safety ground) at the power outlet. For instruments designed to be hard-wired to the supply mains, the protective earth terminal must be connected to the safety electrical ground before any other connection is made. Any interruption of the protective ground conductor or disconnection of the protective earth terminal will cause a potential shock hazard that might cause personal injury.
Erdungskonzept: Dieses Produkt ist ein Gerät der Schutzklasse 1. Zur Vermeidung von gefährlichen Energieinhalten und
Spannungen, ist das Gehäuse an eine Schutzerde anzuschliessen. Der PE-Anschluss ist an einen festen Erder anzuschliessen. Bei Festverdrahtung des Gerätes ist sicherzustellen, dass der PE Anschluss als erstes angeklemmt wird Jede mögliche Unterbrechung des PE-Leiters oder Trennung der PE Verbindung kann einen möglichen elektrischen Schlag hervorrufen, der Personenschäden zur Folge hätte.
LIVE CIRCUITS
Operating personnel must not remove the FPS1000 units cover. No internal adjustment or component replacement is allowed by non­TDK Lambda qualied service personnel. Never replace components with power cable connected. To avoid injuries, always disconnect power, discharge circuits and remove external voltage sources before touching components. Restricted Access Area: FPS1000 units should only be installed in a Restricted Access Area. Access should be available to service personnel only
Spannungsführende Teile
Die Geräteabdeckung darf nicht durch Endanwender geönet werden. Interne Modikationen, sowie Bauteileaustausch ist nur durch TDK-Lambda qualiziertes Personal erlaubt. Vor Austausch von Bauteilen ist das Netzkabel bzw. die Versorgungsspannung zu trennen. Energieversorgungsanschlüsse sind immer zu trennen, um Personenschäden durch gefährliche Energieinhalte und Spannungen auszuschliessen. Die Stromkreise sind zu entladen, externe Spannungsquellen sind zu entfernen, bevor auf Bauteile bzw. Komponenten Ebene gearbeitet wird.
Loading...
+ 8 hidden pages