TDK-Lambda CPFE500F-28, CPFE500F-48, CPFE500F-12 Handbook

HANDBOOK FOR CPFE500F SERIES 61006
Issue2
Page 1
GENERAL SAFETY INSTRUCTIONS High Voltage Warning
Dangerous voltages are present within the power supply.
Critical Components
This product is not authorised for use as a critical component in nuclear control systems, life support systems or equipment for use in hazardous environments without the express written approval of the Managing Director of TDK-Lambda UK Ltd.
Servicing
This product is not customer serviceable. Unit repairs shall only be carried out by TDK- Lambda UK Ltd or their authorised agents.
Contact: TDK-Lambda UK Ltd
Kingsley Avenue Ilfracombe Devon, EX34 8ES Tel 01271 856600 Fax 01271 864894
Safety Class of Protection
The unit is designed for the following parameters : Material Group IIIb, Pollution Degree 2, Overvoltage Category II, Class 1 (earthed), Indoor use. The unit is considered as fixed and rated IPX0. The CPFE500F-12 and CPFE500F-24 are classed as having SELV outputs. The CPFE500F-48 is classed as having a NON SELV output. All outputs are capable of providing hazardous energy (>240VA). The final equipment should provide protection to service personnel against inadvertent contact with the PSU output terminals.
Installation
This product is designed for use within other equipment which restrict access to authorised competent personnel only. The unit covers/chassis must not be made user accessible. The appliance may be mounted in any orientation except inverted (baseplate uppermost). The customer has to ensure the baseplate temperature remains below certain limits. Horizontal orientation input 90-149V baseplate temperature limited to 75°C. Horizontal orientation input 150V or greater baseplate temperature limited to 85°C. All other orientations baseplate temperature limited to 85°C. With open frame version, any orientation is permitted at 85°C baseplate temperature. The mains input connector is not acceptable for use as field wiring terminals. The appliance must be securely mounted and the baseplate properly bonded to the main protective earth contact before any connection to AC mains supply is made. The ventilation openings must not be impeded – ensure a space at least 5cm between any obstruction and the ventilation openings.
Environmental Parameters
Operation Storage & Transportation
Temperature -400C to +500C
(note 1,2)
-400C to +850C
Humidity 30% to 90% RH, non-
condensing
10% to 95% RH, non-condensing
Air Pressure 70kPa to 106kPa 54kPa to 106kPa Altitude -200m to 2000m -200m to 2000m
* Note 1 – heatsinking must be provided to ensure the PSU baseplate temperature does not exceed 85DegC (see diagram for measurement location) and installation notes. * Note 2 – For 3 year life expectancy, continuous temperature of electrolytic capacitors should not exceed :- C11,12,25,26 67.5°c
C22,23,16,17 81°c
Level of Insulation
Primary mains circuit to earth 2.25~2.35KVDC Primary mains circuit to output 4.25~4.35KVDC Output to earth 500VDC max
Input Parameters
Maximum input voltage range 85 – 265VAC
(note 3)
Nominal input voltage range 100 – 240VAC Input frequency range 47 – 63 Hz
(note 3)
Maximum input current 8.2Arms Earth leakage 1650µA Max Efficiency (25°c,100% Load) 80% min
* Note 3 - In cases where conformance to various specs (UL, EN) are required, input voltage range will be 100~240VAC(50/60Hz).
Output Parameters
CPFE500F-12 CPFE500F-28 CPFE500F-48 Nom output Voltage 12VDC ± 1% 28VDC ± 1% 48VDC ± 1% Max adjust range
(note 4)
9.6-14.4V 22.4-33.6V 38.4-57.6V Maximum output current
42A 18A 10.5A
Overcurrent protection 105-140% 105-140% 105-140% Overvoltage Protection
125-145% latched shutdown
125-145% latched shutdown
125-145% latched shutdown
Over-temp Protection Latched Shutdown
at 90~115°C baseplate temperature
Latched Shutdown at 105~130°C baseplate temperature
Latched Shutdown at 105~130°C baseplate temperature
* Note 4 - Max output power is limited to 504W
HANDBOOK FOR CPFE500F SERIES 61006
Issue2
Page 2
CONNECTION DETAILS Input Connection
Mains input connection by 3way AMP 'Mate-n-lock' connector Mating 3-way housing: AMP 350766-1. Mating crimp terminals: AMP 926893-1 (14~20AWG), 926895-1 (18~24AWG)
Pin 3 : Live Pin 2 : Earth Pin 1 : Neutral
Internal Fuse Type: F15AH 250V
Output Power Connection
DC output +ve & -ve connection by two M6x18 studs, max torque 10Nm. Use appropriate ring terminals and wire for the load and short circuit current.
Output Signals
Signal connections available on two 10-way 2.5mm header connectors (ref J2,J3). Mating 10-way housing : Molex 22-01-1103. Mating crimp terminals : 08-50-0032 (22~30AWG) Pinout :-
J2,J3 Pin Function
1 + Sense 2 - Sense 3COM 4 - remote on/off 5 + remote on/off 6Aux 7 Current share 8Trim 9ENA
10 IOG
Safety Approvals
UL/CSA 60950-1, IEC/EN60950-1 Intended for installation in a non-operator access environment
Intended for installation in an external electrical/mechanical fire enclosure.
EMC & IMMUNITY
Conducted Emissions - EN55022 Class B Radiated Emissions - EN55022 Class B
(Note 5)
Immunity - EN61000-4-2, -3, -4, -5, -6, -8, -11
(Note 5) see application note for curve B
FAULT FINDING
If the unit shuts down, switch off or remove the supply as it could be that an over voltage or over temperature condition has occurred. In the event of an over temperature condition, ensure the unit has cooled down before re-applying the supply. If the unit still fails to power up, return to TDK-Lambda UK Ltd for investigation and repair.
MECHANICAL DIMENSIONS