TDK ZMG-11, ZMG2203-11, ZMG2202-11, ZMG2203-M, ZMG-M User Manual

...
(1/3)
EMC Filters for AC Power Line
Conformity to RoHS Directive
For Single-phase, Small-size Box Cased ZMG-11, ZMG-M Series
FEATURES
• The ZMG series EMC filters exhibit outstanding attenuation
characteristics with respect to both differential mode and com-
• Small, high performance, this series demonstrates superior
attenuation effects for low frequency band noise components
under 1MHz. It is therefore suitable for conform to FCC and VDE
standards relating to switching power supply use devices.
• Current leakage is maintained at less than 0.5mA.
• Efficient manufacturing makes these filters highly cost-effective.
• ZMG-M series is compact on-board type.
• It is a product conforming to RoHS directive.
APPLICATIONS
Computer terminals, office automation equipment, digital applied
devices (ECRs, electronic calculators, electronic scales, etc.), con-
trol devices, measurement devices, and any other devices that
require a miniaturized filter.
SHAPES AND DIMENSIONS
Ground terminal
SAFETY STANDARDS
Standard and standard No.
Par t N o.
ZMG22R5-11 1052559 LR76849C P08209004 ZMG2202-11 1052559 LR76849C P08209004 ZMG2203-11 1052559 LR76849C P08209004 ZMG2206-11 1052559 LR76849C P08209004 ZMG2201-M 1052555 LR76849C P08209004 ZMG2203-M 1052555 LR76849C P08209004 ZMG2206-M 1052555 LR76849C P08209004
U.S.A. Canada Europe
UL(NRTL)
UL1283 CSA C22.2 No.8 EN60939
CSA
NEMKO
14
A
23
B
Series ABCDEF øG ZMG-11 31 44.5 22 3.5 10 35 1 ZMG-M 2525263.510201
• Case: plastic, terminal: pin
CD
øG
EE
F
Dimensions in mm
• Conformity to RoHS Directive: This means that, in conformity with EU Directive 2002/95/EC, lead, cadmium, mercury, hexavalent chromium, and specific bromine-based flame retardants, PBB and PBDE, have not been used, except for exempted applications.
• All specifications are subject to change without notice.
003-01 / 20080818 / e9145_zmg.fm
(2/3)
ELECTRICAL CHARACTERISTICS
Part No. ZMG22R5-11 ZMG2202-11 ZMG2203-11 ZMG2206-11 Rated voltage Eac(V) 250 250 250 250 Rated current(A) 0.5 2 3 6 Test voltage Eac(V)[Between terminal and ground terminal] 1500 1500 1500 1500 Insulation resistance(MΩ) [DC. 500V, 1min/between terminal and ground terminal] Leakage current(mA)[250V • 60Hz] 0.5max. 0.5max. 0.5max. 0.5max. DC resistance(mΩ) 450max. 350max. 230max. 60max. Operating temperature range(°C)[Including self-temperature rise] –25 to +85 –25 to +85 –25 to +85 –25 to +85 With derating over(°C) 55555555 Temperature rise(°C) 30max. 30max. 30max. 30max. Attenuation frequency range (MHz)[+5 to +35°C] Weight(g) 36363640
Part No. ZMG2201-M ZMG2203-M ZMG2206-M Rated voltage Eac(V) 250 250 250 Rated current(A) 1 3 6 Test voltage Eac(V)[Between terminal and ground terminal] 1500 1500 1500 Insulation resistance(MΩ) [DC. 500V, 1min/between terminal and ground terminal] Leakage current(mA)[250V • 60Hz] 0.5max. 0.5max. 0.5max. DC resistance(mΩ) 140max. 120max. 60max. Operating temperature range(°C)[Including self-temperature rise] –25 to +85 –25 to +85 –25 to +85 With derating over(°C) 55 55 55 Temperature rise(°C) 30max. 30max. 30max. Attenuation frequency range (MHz)[+5 to +35°C] Weight(g) 242424
Differential mode at 30dB 0.45 to 10 0.7 to 10 0.8 to 10 2 to 10 Common mode at 30dB 0.1 to 10 0.2 to 10 0.3 to 10 1 to 10
Differential mode at 25dB 0.8 to 10 0.8 to 10 1.5 to 20 Common mode at 25dB 0.6 to 10 0.6 to 10 3 to 10
100min. 100min. 100min. 100min.
100min. 100min. 100min.
• All specifications are subject to change without notice.