TDK NB Series, NB-80E-01-H User Manual

• All specifications are subject to change without notice.
• Conformity to RoHS Directive: This means that, in conformity with EU Directive 2002/95/EC, lead, cadmium, mercury, hexavalent chromium, and specific bromine-based flame retardants, PBB and PBDE, have not been used, except for exempted applications.
NB series
Ultrasonic Nebulizer Units
Humidifier for mist generating system Incorporate type
(1/3)
002-03 / 20120316 / ef441_nb.fm
• All specifications are subject to change without notice.
Ultrasonic Nebulizer Units Incorporate Type
NB Series
The TDK ultrasonic humidifier unit was the first such product in the world to be developed. There is an increasing need for indoor humidification due to the proliferation of clean air heat pumps and central heating systems. When the appropriate amount of humidity is added as determined by the relationship between humidity and sensible temperature (temperature perceived by the body), humidification is advanta-
geous from the standpoint of both health and reduced energy con­sumption. In addition to such home uses, these ultrasonic humidifier units have numerous advantages for humidification of vegetable show­cases, preservation and growth of agricultural products, industrial applications, etc. A wide variety of standard units are available from TDK.
ELECTRICAL CHARACTERISTICS
• The character at the end of the product number indicates the transducer’s direction of tilt.
EXAMPLE OF ATOMIZATION CHAMBER CONSTRUCTION TYPICAL TRANSDUCER INSTALLATION
TYPICAL CHARACTERISTICS OF HUMIDIFIER UNITS
VOLTAGE CHARACTERISTICS(48V) WATER TEMPERATURE CHARACTERISTICS(48V) WATER LEVEL CHARACTERISTICS
Part No. NB-59S-09S-0 NB-80E-01-H
Rated input voltage
Eac(V) 48±10%
Edc(V) 12±10% Power consumption (W) 30±5 13.2max. Mist output ratio (l/h) 45010
–3
min. (150+100, –50)10
–3
Ultrasonic frequency (kHz) 1600 to 1750 2350 to 2600 Normal water level (mm) 40 35 External potentiometer (k )— 10 Operating water temperature range (°C) 0 to 45 0 to 45 Water quality Drinking water Drinking water Transducer element life (h) 10000 5000 Cooling method Water cooled Air cooled Parallel connected operation Yes Yes Weight (g) 60 60 Main application Various humidity control systems Microparticle applications such as for medical use
Air-flow
Mist
Mist discharge tube
Atomization chamber
Float switch
Power transformer
Ultrasonic humidifier unit
Fan moter
Transducer
Drive
circuit
Water tank
35 to 45mm
13mm
Transducer (tilted about 7°)
The direction of water column
Air-flow
The tilt direction of transtucer will be the
same as the direction of water column.
The arrows indicate the tilt direction of the transducer.
Tilt directions of the transducer
NB-59S-09S Type
Transducer
+40
+20
48V+10
(
52.8V
)
+20
(
57.6V
)
+30
(
62.4V
)
–20
(
38.4V
)
–10
(
43.2V
)
–30
(
33.6V
)
–60
–40
–20
Input voltage ratio(%
)
Mist generation
ratio(%)
[
0%=550
(
ml/hr
)]
700
600
500
Mist output
(
ml/hr
)
Water temperature(˚C
)
10 20 30 40 50
600
400
200
Mist output
(
ml/hr
)
Water level(mm
)
30 35 40 45 50
48V series
24, 12V series
(2/3)
002-03 / 20120316 / ef441_nb.fm
• All specifications are subject to change without notice.
NB-59S-09S TYPE
FEATURES
• Compact, with highly reliable circuitry.
• Separate transducer and drive circuit sections provide superior
layout versatility.
SHAPES AND DIMENSIONS
NB-80E-01 TYPE
FEATURES
• Compact, with highly reliable circuitry.
• Separate transducer and drive circuit sections provide superior layout versatility.
• Because the ultrasonic frequencies used are higher than with typical household-type units, mist particle size is extremely fine. This part is thus ideal for products intended for smaller spaces.
SHAPES AND DIMENSIONS
1C
24±0.2 2-ø4.520±0.2
22±0.5
7±0.2
54±1
(
2-C3
)
68
32± 0.2
42±0.5
30±0.5
Yellow AWG-24
Orange AWG-24
100±10
Supporting rubber
Transducer
ø24±0.4
4.5max. 9
Transistor
Aluminum base
PCB
Driver circuit area
5
20max.
3max.
Dimensions in mm
18max.
4.5max.
9.5max.
43.5max.
ø24±0.4
ø18±0.3
32±0.2
31.5max.
120 ±15
TU- 51X-H
4123
2-ø4.5±0.2
2-R5.5
2-R15.6
Dimensions in mm
21max.
26max.
TYPE
NB-80E-01
63C
NO.
65max.
5max.
53±0.2
20.75 ±0.2
1±0.2
40±0.2
2-ø3.5
32.5 ±0.2
Connector for VR(3 poles) 3022-03A Housing 5224-03CHPB Maker: Molex
Connector for power supply(2 poles) 3022-02A 5224-02CHPB
(3/3)
002-03 / 20120316 / ef441_nb.fm
• All specifications are subject to change without notice.
MOUNTINGS (Reference)
1.NB59S, NB-80E TYPES
The transducer can beak off if the A dimension depth is shallow. TDK recommends a 2mm A-dimension depth and a screw tighten­ing torque of 0.6N • m.
2.CONSTRUCTION OF NB59S
The drawing below shows an example method for transistor heat dissipation. The attached aluminum cooling fins should fixed using silicon rubber to a metallic water tank, etc. with sufficient head dis­sipation capacity. (It is recommended to use a plastic water tank. However, if a metallic water tank is absolutely must be used, be sure to insulate it from the power supply line.)
PRECAUTIONS
• These units are readily damaged by operation when empty (without water). Therefore a means (float switch, etc.) should be provided to assure operation does not occur when empty.
• Contact TDK prior to use of this unit for applications utilizing liquids other than water.
• The unit should be used only after sufficient consideration of the product specifications for that specific unit.
• When using units in parallel, make sure that voltage differences do not occur between the individual transducers.
• Do not use the unit to atomize a liquid other than drinking water. Doing so can deteriorate the transducer.
• Do not operate the transducer when the atomization unit tank is not charged with drinking water.
• Drain water from the transducer and clean the equipment into which the unit is incorporated if not used for a long period of time.
• Clean the transducer periodically to prevent any degradation in the atomizing capacity due to buildup in the transducer of such substances as calcium, sodium, magnesium, and silicon, commonly found in drinking water.
• TDK is not responsible for damage to the transducer resulting from use of oscillator circuitry not supplied or not approved by TDK.
• TDK is not responsible for worsening of unit performance resulting from operation in environments other than those recommended, storage in environments other than those recommended, or use of the unit in configurations other than those recommended by TDK for efficient mist generation.
• TDK is not responsible for the vaporization of pathogenic bacteria or particles, not responsible if drinking water contains substances that impede vaporization, and not responsible for bacterial growth due to lack of a water purification function.
• Please select a plastic material of construction for the water tank design. Metallic construction can result in electrolytic corrosion between the chamber base and water tank. Furthermore, if multiple units are used with the same tank, and if each unit is equipped to be separately turned ON/OFF, the power supply terminal for each unit should use a double-pole switch.
Screw:M4×15
Rubber packing
Tank base
ø24
ø18
A
Dimensions in mm
Plastic case (Metal case)
P.C. boardMetal tank
Transducer unit
Silicon rubber
Aluminum radiation board