Data Sheet: Veta iHA48040A033V*, 3.3V/40A Output Half Brick Series
Platform Overview:
Veta iHA48 Series DC-DC Power Modules
48V Input, 1.2-28V/60A or 350W Output
Half-Brick
The Veta iHA48 Series power modules operate
over a wide 36 – 75Vdc input voltage range and
provide one regulated dc output voltage that is
electrically isolated from the input. Its high
efficiency and superior thermal performance make
the Veta Family of power modules ideally suited
for power-hungry applications in demanding
thermal environments. This rugged building block
is designed to serve as the core of your high
reliability system. A wide output voltage trim range
and remote sensing are standard features
enhancing versatility.
Standard Features:
• Standard Half Brick footprint
• High efficiency, 83-93.5%
typical
• Wide output trim voltage
• Up to 60A of true usable current
• Industry-leading output power:
up to 350W
• Monotonic start-up
• Monotonic start-up into a pre-
biased output
• Basic insulation – 1500 Vdc
• Constant switching frequency
• Auto-recovery protection:
o Input under and over
voltage
o Current limit
o Short circuit
o Thermal limit
• Latched output over voltage
protection
• High reliability open frame,
surface-mount construction
• Baseplate for improved thermal
management
• UL 60950 (US and Canada),
VDE 0805, CB scheme
(IEC950), CE Mark (EN60950)
Data Sheet: Veta iHA48040A033V*, 3.3V/40A Output Half Brick Series
Absolute Maximum Ratings:
Stress in excess of Absolute Maximum Ratings may cause permanent damage to the device.
Characteristic Min Max Unit Notes & Conditions
Continuous Input Voltage -0.5 80 Vdc
Transient Input Voltage --- 100 Vdc 100mS max.
Isolation Voltage --- 1500 Vdc
Storage Temperature -55 125 °C
Operating Temperature Range (Tc) -40 115* °C
Flatness 0.006 In.
•Engineering estimate
Maximum base plate temperature. Measured at the
location specified in the thermal measurement
figure.
Bare component side of metal board shall be
convex.
Common Input Characteristics:
Unless otherwise specified, specifications apply over all Rated Input Voltage, Resistive Load, and Temperature conditions.
Characteristic Min Typ Max Unit Notes & Conditions
Operating Input Voltage 36 48 75 Vdc
Turn-on Voltage --- 34.6 36 Vdc
Turn-off Voltage 30 32.7 --- Vdc
Hysteresis 0.5 1.9 --- Vdc
Input High Voltage Turn-off --- 79 80 Vdc
Input High Voltage Turn-on 75 77 --- Vdc
Hysteresis --- 2 --- Vdc
Startup Delay Time from application of input voltage --- 15 --- mS
Startup Delay Time from on/off --- 10 --- mS
Inrush Transient --- --- 0.06 A2s
* Engineering estimate
Vo = 0 to 0.1*Vo,nom;on/off =on,
Io=Io,max, Tc=25°C
Vo = 0 to 0.1*Vo,nom; Vin = Vi,nom,
Io=Io,max,Tc=25°C
Electrical Data:
Input Characteristic Min Typ Max Unit Notes & Conditions
Maximum Input Current --- --- 4.5* A Vin = 0 to Vin,max, Io,max, Vo=Vo,nom
Output Voltage Rise Time --- 20 --- mS Io=Io,max,Tc=25°C, Vo=0.1 to 0.9*Vo,nom
Data Sheet: Veta iHA48040A033V*, 3.3V/40A Output Half Brick Series
Electrical Data (continued):
Operating at Tc = 25°C unless otherwise specified
Output Characteristic Min Typ Max Unit Notes & Conditions
Output Voltage Initial Setpoint
Output Voltage Tolerance
Efficiency
Line Regulation --- 2 6* mV Vin=Vin,min to Vin,max
Load Regulation --- 6 10* mV Io=Io,min to Io,max
Temperature Regulation --- 10 30* mV Tc=Tc,min to Tc,max
Output Current
Output Current Limiting Threshold
Short Circuit Current
3.25 3.3 3.35 Vdc Vin=Vin,nom; Io=Io,max;
3.2 --- 3.4 Vdc Over all rated input voltage, load, and
--- 91.5 --- % Vin=Vin,nom; Io=Io,max;
0 --- 40 A At loads less than 25% of Io,max the module
40.6 46 60 A Vo = 0.9*Vo,nom, Tc<Tc,max
--- 60 --- A Vo = 0.25V
--- 40 55 mVpp Output Ripple and Noise Voltage
--- 10
15 mVrms
temperature conditions to end of life
will continue to regulate the output voltage,
but the output ripple may increase
Measured across one 47uF, one 1uF and
one 0.1uF ceramic capacitors – see
input/output ripple measurement figure; BW =
20MHz
Output Voltage Adjustment Range 50 --- 110 %Vo,nom
Output Voltage Sense Range --- --- 10 %Vo,nom
Dynamic Response:
Recovery Time
Transient Voltage
Output Voltage Overshoot during startup --- 0 --- mV Io=Io,max
Switching Frequency --- 300 --- kHz Fixed
Output Over Voltage Protection --- 4.0 --- V All line, load, and temperature conditions
External Load Capacitance 50 --- 60000** uF
Isolation Capacitance --- 2000 --- pF All line, load, and temperature conditions
Isolation Resistance 10 --- ---
Vref 1.225 V Required for trim calculation
* Engineering Estimate
** Contact TDK Innoveta for applications that require additional capacitance
Caution: The power modules are not internally fused. An external input line normal blow fuse with a maximum value of 10A is required, see
the Safety Considerations section of the data sheet.
---
---
0.25
100
---
---
mS
mV
MΩ
di/dt = 0.1A/uS, Vin=Vin,nom; load step from
50% to 75% of Io,max.
For applications with large step load changes
and/or high di/dt load changes, please
contact TDK Innoveta for support.