TDE Instruments Digalox DPM72-AVP User guide

Instruction manual
to download
Panel meter Digalox DPM72,
condensing
Failure to comply with these instructions will
Preferred supply of USB devices via scre
Supply via USB in operation, USB supply voltage must be at least 5V.
Note: the measurement inputs of the device can carry life
device
The device must not be used as the only protective device or protective
Read instruction manual
The device is not intended to protect persons or facilities against harm. Specific
devices must be used to gua
connecting switches
is at least
when measuring
housing!
the instrument
carrying hazardous
Manager”
x
all guarantee and warranty.
w terminals with 10 to
hazardous voltages must not be connected
carefully before operating the device!
ction relais, off
switches must
maximum occurring
must be isolated
flammable substances!
with external
Digalox DPM72-AVP
Visit www.digalox.com
1. Intended Use
Indoor use non
Panel mounting.
2. Safety instructions
voltages!
When working on the
(Rev-2015-04)
software “Digalox
, non corrosive.
5x jumpers, 1
void
.
mounting bracket
24V AC/DC.
-threatening
to
the device!
shutdown.
When
whose isolation voltage voltage. For example, least 500V.
Do not open the
Do not use
All cables
separators.
rantee safety (prote
to the terminals J1-J6 only
twice the
250V AC switch
in the presence of explosive or
voltages must be secured
-switches, etc). be used
measurement
for at
----- 1 -----
3. Description The measure modes volt AC/DC, ampere, frequency and 5A current transformer are supported. Scale endpoint of the indicator as well as scaling of the analogue signal and current transformer measurement can be adjusted freely via the DIP switch, alternatively there is an option for automatic adaption of the scale endpoint. The unit can be switched between volt and ampere measurement via an external switch. Minimum and maximum values are recorded and can be displayed optionally using an external switch. Measured values are recorded over a time span of 3 minutes up to 14 days. The time base as well as the display of the measuring history can be activated by an external switch. The following parameters can be adjusted using the USB-Software: Scale­endpoint, scale-caption, display-style (pointer, tachometer, bar graph, and more), splash display, thresholds for alarm output, hysteresis, and more. Recorded measurement values can be read and a continuous transmission of the actual measuring value can be enabled. Using the software, values can be viewed and exported as CSV.
Front
1 Unit or free text 2 Threshold value 3 Upper scale caption 4 Graphical measurement display 5 Digital measurement value 6 Lower scale caption
Back
1 2 optocoupler switch outputs 2 DIP switch for setting measurement
mode and upper scale caption 3 Supply voltage input 4 Jumpers for configuration or connection
external switch for activating/switching
measurement mode, graphical historic
data display, min/max display, auto-
scaling 5 USB interface for alternative power
supply and software communication
interface 6 Measurement inputs
----- 2 -----
4. Electrical Connections
The device may only be operated in one of the connection options shown below.
10-24V
Fuse 250mA
U
s
DPM72 AV/P
Voltage and current
direct measurement
Measurement inputs
10A
I
high
Load
I
low
max.
Supply
U
high
max.
500V
+/L -/N
U
U
s
low
10-24V
Voltage direct, current via
I
low
Current
transformer
Fuse 250mA
U
s
Supply
DPM72 AV/P
current transformer
Measurement inputs
I
high
Load
U
high
max.
500V
+/L -/N
U
U
s
low
10-24V
Load
Fuse 250mA
U
s
Supply
DPM72 AVP only!
Voltage and current direct
measurement, high side
Measurement inputs
I
low
I
high
AVP
only!
max.
50V!
U
high
U
U
s
low
Warning:
Voltage measurement on the high side (between plus and load) is recommended only for voltages up to 50V!
In this case the entire device is on high potential. Particularly to be considered when connecting switches to JP1-6.
+/L -/N