SAFETY RULES AND RECOMMENDATIONS FOR THE INSTALLER
Read this guide before installing and using the
appliance.
During the installation of the indoor and outdoor units the access to the working area should
be forbidden to children.
Unforeseeable accidents could happen.
Make sure that the base of the outdoor unit is
firmly fixed.
Check that air cannot enter the refrigerant system and check for refrigerant leaks when moving the air conditioner.
Carry out a test cycle after installing the air conditioner and record the operating data.
The ratings of the fuse installed in the built incontrol unit are T 5A / 250V .
The user must protect the indoor unit with a
fuse of suitable capacity for the maximum input current or with another overload protection
device.
Check that the socket is suitable for the plug ,
otherwise have the socket changed.
The appliance must be fitted with means for
disconnection from the supply mains having
a contact separation in all poles that provide
full disconnection under overvoltage
category III conditions, and these means
must be incorporated in the fixed wiring in
accordance with the wiring rules.
The air conditioner must be installed by
professional or qualified persons.
Do not install the appliance at a distance of
less than 50 cm from inflammable substances
(alcohol, etc.) Or from pressurised containers
(e.g. spray cans).
If the appliance is used in areas without the
possibility of ventilation, precautions must be
taken to prevent any leaks of refrigerant gas
from remaining in the environment and creating a danger of fire
This appliance is not intended for use by
persons (including children) with reduced
physical, sensory or mental capabilities, or
lack of experience and knowledge, unless they
have been given supervision or instruction
concerning use of the appliance by a person
responsible for their safety.
Children should be supervised to ensure that
they do not play with the appliance.
The appliance must be installed in accordance
with national wiring regulations.
1
SAFETY RULES AND RECOMMENDATIONS FOR THE USER
Do not try to install the conditioner alone;
always contact specialized technical personnel.
Cleaning and maintenance must be carried out
by specialised technical personnel. In any case
disconnect the appliance from the mains electricity supply before carrying out any cleaning
or maintenance.
Ensure that the mains voltage corresponds to
that stamped on the rating plate. Keep the switch or power plug clean. Insert the power plug
correctly and firmly into the socket , thereby
avoiding the risk of electric shock or fire due
to insufficient contact.
Do not pull out the plug to switch off the appliance when it is in operation, since this could
create a spark and cause a fire, etc.
This appliance has been made for air conditioning domestic environments and must not be
used for any other purpose , such as for drying
clothes, cooling food, etc.
The packaging materials are recyclable and
should be disposed of in the separate waste
bins . Take the air conditioner at the end of its
useful life to a special waste collection centre
for disposal.
Always use the appliance with the air filter
mounted . The use of the conditioner without
air filter could cause an excessive accumulation
of dust or waste on the inner parts of the device
with possible subsequent failures.
The user is responsible for having the appliance
installed by a qualified technician , who must
check that it is earthed in accordance with current legislation and insert a thermomagnetic circuit breaker.
The batteries in remote controller must be
recycled or disposed of properly.
Disposal of Scrap Batteries --- Please discard the batteries as sorted municipal waste at
the accessible collection point.
Never remain directly exposed to the flow of
cold air for a long time. The direct and prolonged exposition to cold air could be dangerous for your health .Particular care should be
taken in the rooms where there are children ,
old or sick people.
If the appliance gives off smoke or there is a
smell of burning, immediately cut off the pow
er supply and contact the Service Centre.
The prolonged use of the device in such
conditions could cause fire or electrocution.
Have repairs carried out only by an authorised Service Centre of the manufacturer . Incorrect repair could expose the user to the risk
of electric shock, etc.
Unhook the automatic switch if you foresee
not to use the device for a long time.
The airflow direction must be properly adjusted.
The flaps must be directed downwards in
the heating mode and upwards in the cooling
mode.
Only use the air conditioner as instructed in
this booklet.These instructions are not intended to cover every possible condition and situation.As with any electrical household appliance, common sense and caution are therefore
always recommended for installation , operation and maintenance.
Ensure that the appliance is disconnected from
the power supply when it will remain inoperative for a long period or before carrying out
any cleaning or maintenance.
Selecting the most suitable temperature can prevent damage to the appliance.
2
SAFETY RULES AND PROHIBITIONS
Do not bend , tug or compress the power cord
since this could damage it. Electrical shocks or
fire are probably due to a damaged power cord.
Specialised technical personnel only must replace a damaged power cord.
Do not use extensions or power board.
Do not touch the appliance when barefoot or
parts of the body are wet or damp.
Do not obstruct the air inlet or outlet of the indoor or the outdoor unit.
The obstruction of these openings causes a reduction in the operative efficiency of the conditioner with possible consequent failures or
damages.
In no way alter the characteristics of the appliance.
Do not install the appliance in environments
where the air could contain gas , oil or sulphur
or near sources of heat.
Do not climb onto or place any heavy or hot
objects on top of the appliance.
Do not leave windows or doors open for long
when the air conditioner is operating.
Do not direct the airflow onto plants or animals.
A long direct exposition to the flow of cold
air of the conditioner could have negative
effects on plants and animals.
Do not put the conditioner in contact with
water.
The electrical insulation could be damaged
and thus causing electrocution.
Do not climb onto or place any objects on the
outdoor unit
Never insert a stick or similar object into the
appliance. It could cause injury.
Children should be supervised to ensure
that they do not play with the appliance.
If the supply cord is damaged, it must be
replaced by the manufacturer,its service
agent or similarly qualified persons in
order to avoid a hazard.
3
NAMES OF PARTS
INDOOR UNIT
No.
Description
1
Front panel
2
Air filter
Optional filter (if installed)
3
4
LED Display
5
Signal receiver
Terminal block cover
6
Ionizer (if installed) generator
7
Deflectors
8
9
Emergency button
10
Indoor unit rating label ()Stick position optional
Airflow direction louver
11
Remote controller
12
OUTDOOR UNIT
Description
No.
Air outlet grille
13
Outdoor unit rating label
14
Terminal block cover
15
gas valve
16
liquid valve
17
INDOOR UNIT
4-5
2-3
1
10
6
9
10
11
CL
OC
K
DIS
PL
AY
3D
HE
ALTH
Y
FA
O
N
N
/O
F
TI
F
ME
R
SL
EE
EC
SW
P
O
IN
G
SU
PER
MO
DE
12
13
8
7
14
15
OUTDOOR UNIT
Note: the above figures are only intended to be a
simple diagram of the appliance and may not
correspond to the appearance of the units that
have been purchased.
4
16
17
INDOOR UNIT DISPLAY
12
3
5
4
/O
1
5
2
1
2
3
54
4
3
3
4
2
1
24
3
3
1
5
2
3
4
5
1234
No.
Led
1
POWER
2
SLEEP
Temperature display (if present)
3
/Error code
TIMER
4
5
RUN
The shape and position of switches and indicators may be different according to the model, but their
function is the same.
Function
This symbol appears when the unit is power on
SLEEP mode
(1) Lights up during Timer operation when
the air conditioner is operational
(2)Displays the malfunction code when fault
occurs.
Lights up during Timer operation.
The symbol appears when the unit is turned
on, and disappear when the unit is turned off.
5
EMERGENCY FUNCTION & AUTO-RESTART FUNCTION
AUTO-RESTART FUNCTION
The appliance is preset auto - restart function by
manufacturer. In case of a sudden power failure, the
module memorizes the setting conditions before the
power failure. when the power restores, the unit
restarts automatically with all the previous settings
preserved by the memory function.
To deactivate the AUTO-RESTART function ,proceed as follows:
1. Switch the air conditioner off and remove the
plug.
2. Press the emergency button meanwhile plug
it in.
3. Keep pressing the emergency button for more
than 10 seconds until you hear four short beeps
from the unit. The AUTO-RESTART function is
deactivate.
To activate the AUTO - RESTART function ,
follow the same procedure until you hear three
short beeps from the unit.
P
O
W
E
R
S
L
E
E
P
Emergency
button
ON / OFF
T
IM
E
R
R
U
N
Emergency
button
EMERGENCY FUNCTION
display PCB
If the remote controller fails to work or maintenance
necessary,proceed as follows:
Open and lift the front panel up to an angle to reach the
ON/OFF
emergency button.
1. One press of the emergency button(one beep) will
lead to the forced COOLING operation
2. Two press of the emergency button within 3 sec
(two beeps) will lead to the forced HEATING
Emergency
button
ON/OFF
operation.
3. To switch off the unit , you just need to press the
button again ( a single long beep) .
1033A
4. After 30 minutes in forced operation , the air
conditioner will automatically start working in 23
cooling mode, auto fan speed.
* The FEEL function is described in page 13.
The emergency button in some models could be on
the right part of the unit under the front panel.
The shape and position of the emergency button
may be different according to the model, but their
function is the same.
Remark: the external static pressure of heat pumps is 0 Pa for all models.
The indoor fan speed during capacity and or efficiency test should be "quick cool" or "quick heat"
which can be activated by pressing "TURBO" or "SUPER" button of remote controller; Please contact
with the seller in case of failing in activating it.
front panel
front panel
6
REMOTE CONTROLLER
No.
1
2
3
4
5
6
7
8
SUPER or TURBO
9
10
11
12
13
14
Button
(TEMP UP)
(TEMP DN)
ON/OFF
FAN
TIMER
SLEEP
ECO
MODE
SWING
CLOCK
DISPLAY
HEALTHY
RESET
Function
Press it to increase temperature / time setting.
Press it to decrease temperature/ time setting.
Press it to start or stop operation.
To select the fan speed of auto/low/mid/high
Press it to set auto-off timer.
To activate the function SLEEP
In cooling mode,press this button ,the temperature
will increase 2 on the base of setting temperature
In heating mode, press this button, the temperature
will decrease 2 on the base of setting temperature
To select the mode of operation
Press this button to activate / deactivate the Super
function which enables the unit to reach the preset
temperature in the shortest time.
In COOL mode, the unit will give the maximum
cooling temperature with 16 ,high fan speed.
In HEAT mode, the unit will give the maximum heating
temperature with 31 ,high fan speed.
To activate or deactivate of the movement of the
deflectors.
When you press this button,the time will be flickering;then through" "and " ",you can adjust
the time(one time you press,one minute you adjust;and if you continue to hold,the time changes
rapidly ), after adjusting to your required time,
please press this button again to fix the time.
To LED displayswitch on/off the
To switch - on /off HEALTHY funtion.It is a button
which controls the ionizer or plasma generator only
for inverter models.
To restart REMOTE CONTROLLER
1
2
3
4
5
6
7
1
2
3
8
4
5
6
10
12
3
8
4
6
10
13
6
5
8
DISPLAYHEALTHY3D
CLOCK
ON/OFF
FAN
SWING
TIMER
ECO
SUPER
SLEEPMODE
FEEL
AUTOQUIET
COOL
POWERFUL
C
DRY
hr
FAN
DELAY
OFF
ON
HEAT
HEALTHY
TIMER
ON/OFF
ANTI-MILDEW
MODE TIMER
FAN SPEED SUPER ECO
SWING SLEEP HEALTHY
DISPLAY RESET
MODE
ECO
TIMER
SLEEP
FAN
DISPLAY
SWING
SWING
TURBOHEALTHY
Dry
Heat
Fan
Feel Cool
C
h
Auto
Low
Mid
High
Sleep
Swing
SLEEP
TIMER
MODE
13
12
11
10
9
8
FAN
SPEED
AIR
SWING
ON
15
9
7
13
14
1
2
7
5
12
10
9
Timer
OFF
Timer
ON
1
FAN
4
SWING
10
3
ON/OFF
2
ANTI-MILDEW
15
To activate the function ANTI-MILDEW
The outlooking and some function of remote control may vary according
to the model.
The shape and position of buttons and indicators may vary according to
the model, but their function is the same.
The unit confirms the correct reception of each press button with a beep.
7
1
2
4
SWING X
SWING YSUPER
FEEL
COOL
DRY
FAN
HEAT
TIMER ON TIMER OFF
MODE
ON/OFF
TIMER
SWING X SWING Y
FAN
SUPERSLEEP
10
AUTO
HIGH
MID
LOW
SLEEP
3
8
5
6
Loading...
+ 22 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.